INSTALLATION AND ASSEMBLY

INSTALLATION AND ASSEMBLY

iV-Compact ventilation system 

 Installation and operating instructions

iV-Compact ventilation system 

 Installation and operating instructions

4.5 

Installing the weather protection hood

NOTE

Installation on an unfinished exterior wall

results in damage to the exterior wall!

• 

Only install the weather protection hood (exterior closure) once the exterior wall is finished 

and completely hardened.

NOTE

Penetration of condensate and/or algae build-up around the weather protection hood

results in damage to the masonry/exterior wall and/or discoloration of the façade!

• 

Affix all sealing tapes prior to installing the weather protection hood base plate.

•  Carry out a biocide/water-repellent pre-treatment on the render around the weather protection 

hood in vulnerable areas (Consult your planner for further information!).

Spirit level, pen, drilling machine with drill bit Ø 8 mm, electrical screwdriver, wall plugs 

(insulation plugs when using Simplex or with insulated exterior walls), permanently 

elastic outdoor sealant, sealing tape, screws

Requirements: 

The 

exterior wall is finished and level.

 

The wall sleeve is fitted.

 

Remove the protective disc from the wall sleeve 

on the exterior wall side.

 

Push the base plate onto the protruding wall sleeve.

Observe

 the alignment of the drip rails: The slope 

leads in direction of the ground/bottom.

 

Align the base plate using a spirit level.

 

Mark out the four bore holes for fastening the base 

plate.

NOTE: 

Damage to the masonry/external 

wall due to misaligned drip rails!

•  Make sure that the slopes on both drip rails 

are aligned to down-facing.

Ö

The weather protection hood is installed.

 

Drill the four holes with Ø 8 mm to a depth of min. 

50 mm.

 

Insert the wall plugs into the drill holes.

 

Secure weather protection hood base plate to the 

external wall using four screws.

TIP:

 When screwing the base plate of Compact pro-

tective hood to external walls with insulation or when 

using the WEB wall installation block/ Simlex wall 

build-in system use insulation plugs to ensure safe 

fastening. These are not part of the scope of supply, 

but are available as an option

.

 

Hook the cover of the from the front into the lateral 

screws (blue arrows) of the base plate.

Make sure

 that the washers are placed between 

the cover and the screw.

 

Pull down the cover until it snaps into place.

 

Secure the cover to the base plate using the lateral 

screws.

 

Turn the four lateral screws together with captive 

washers loosely from the outside into the four 

threaded holes (blue arrows) on both sides of the 

base plate.

ø = 8 mm

50 mm

 

Affix the sealing tape, 9 mm, on the external wall 

side and circumferiantally to the base plate: 

• around the opening for the wall sleeve. 

• at a distance of 5 mm from the outer edge.

Make sure that 

the sealing tape does not protrude 

over the inside edge of the wall sleeve opening.

TIP:

 

Apply the sealing tape only immediately before 

mounting the base plate. 

This prevents excessive expanding of the sealing tape 

and facilitates installation.

4 x

4 x

Summary of Contents for iV-Compact

Page 1: ...iV Compact Installation and operating instructions ...

Page 2: ...cessories and spare parts 41 10 Troubleshooting and disposal 42 11 Guarantee and warranty 44 12 Service 44 13 Appendix 1 Wiring protocol 45 14 Appendix 2 Cleaning protocol 46 INHALTSVERZEICHNIS Trademarks copyrights and property rights inVENTer Xenion inVENTron and Clust Air are registered trade marks of inVENTer GmbH The copyright of this document remains with the manufacturer Rights to all conte...

Page 3: ...ation units with heat recovery are used to ventilate living rooms and living spaces They are controlled by a control unit of the inVENTer system General instructions When installing the unit system observe the applicable standards regulations and directi ves In particular the applicable building regulations fire protection regulations and accident prevention regulations of the employers liability ...

Page 4: ...eaning and maintenance CAUTION Operation and or maintenance of the ventilation unit and its controllers must not be carried out by children and or persons who are not fully capable of doing so due to their physical sensory or mental capabilities inexperience or lack of knowledge Young children should be supervised to ensure that they do not play with the unit NOTE Your ventilation unit has scratch...

Page 5: ...ordering a wall sleeve with a length of 285 mm or 495 mm Both versions can be trimmed on site It is controlled via one of the following inVENTer system controllers1 sMove s4 sMove s8 MZ Home Components see fig page 9 Inner cover incl dust filter of class G4 Thermal accumulator insert thermal accumulator and inVENTron Wall sleeve Exterior closure Pollen and activated carbon filter op tions availabl...

Page 6: ...e season independent For special require ments pollen and activated carbon filters are available as an option A decentralised ventilation system is based on the free movement of air between individual pairs of ventilation units Therefore internal doors must not have air tight seals Ensure adequate air transfer measures An air gap of about 10 mm below the door unscrew the hinges by 5 mm use a venti...

Page 7: ... spray is possible Observe the following minimum distances for the unit s wall opening 1 between two ventilation units in push pull operation pair in the same room to avoid the mixing of outdoor air and exhaust air Horizontal or vertical installation Installation with height offset on the same wall Installation diagonally over corners 2 to adjacent components on the exterior wall observe insulatio...

Page 8: ...Protective hood cover 6 Brackets 7 Thermal accumulator 8 inVENTron Xenion reversible fan embedded in two Slim guiding vanes A Inner plaster internal structure B Masonry C Render 1 Upper drip rail 2 Bracket for thermal accumulator 3 x 3 Fastening screws for cover 4 x 4 Bottom drip rail 5 Exterior wall attachment with Ø 8 mm min 50 mm deep 4 x 6 Guidance for fastening screws 4 x 7 Protective grid Fl...

Page 9: ...njury and or material losses Provide protection against falling masonry on the outside of the building Remove objects from immediate vicinity of the building s exterior Drilling machine with core drill attachment or milling drill Ø 180 mm wall slot cutter hammer chissel Positioning of the wall sleeve 3 1 Installation position Minimum distance to adjacent components on exterior wall Observe insulat...

Page 10: ...xterior wall side Lay the fan BUS 4 3 Proceed with fitting the weather protection hood 4 5 Star shaped Ö Ö The Simplex wall build in system is fitted Lay the controller cable three wire braided flex from the control unit to the wall opening for the ventilation unit M in X Fill the plaster wall channel Make sure that the cable end protrudes approx 500 mm into the interior NOTE Laying cables whose s...

Page 11: ...ing foam cutter Requirements The wall opening Ø 180 mm is finished The fan BUS controller cable is in place Y 45 mm X A B C D NOTE Accumulation of condensate inside the wall sleeve Damage to the exterior wall and masonry as well as the building fabric Fix wall sleeve with a slope of 1 2 to the exterior wall Fix the wall sleeve in place inside and outside with mounting wedges to create a slope of 1...

Page 12: ... spirit level Mark out the four bore holes for fastening the base plate NOTE Damage to the masonry external wall due to misaligned drip rails Make sure that the slopes on both drip rails are aligned to down facing Ö Ö The weather protection hood is installed Drill the four holes with Ø 8 mm to a depth of min 50 mm Insert the wall plugs into the drill holes Secure weather protection hood base plate...

Page 13: ...m the packaging Requirement The weather protection hood is installed Remove the protective discs from the wall sleeve From the interior slide the thermal accumulator into the wall sleeve as far as the end stop Make sure that the handle is facing towards the interior Make sure that the controller cable fan BUS is facing towards the interior Trim the controller cable 3 wire to your deter mined wall ...

Page 14: ...ws on plug Plug Cable from controller Socket Cable from fan Starting direction Extract air Starting direction Supply air Terminal Signification Colour Terminal Signification Colour Terminal Colour III GND White V GND Brown CW Blue IV Operating voltage Green IV Operating voltage Green Red V GND Brown III GND White CCW Black TIP When looking from the side the plug in connection forms an S like Suppl...

Page 15: ... Opening closing the inner cover For correct functioning of your ventilation system the ventilation unit s inner cover must be opened Close the inner cover if you take the ventilation unit out of operation This will prevent an undesired air exchange i e an inflow of cold air into the living room In particular situations i e accidents with smoke or leaking gases it is necessary to close all doors a...

Page 16: ...nal maintenance plan may deviate from these recommendations Interval Assembly Maintenance activity Cleaning from the interior room Monthly Pollen filter Replace the contaminated pollen filter Inner cover Clean the surface of the panel with a damp cloth Quarterly Dust filter Wash the dust filter with warm water and detergent Or Replace defective dust filters Interval Assembly Maintenance activity H...

Page 17: ...logo is located on the bottom right Press the side detent lugs inwards on the inner cover base plate s spacers Slide the inner cover panel onto the spacers Ö Ö All spacers noticeably snap in Ö Ö You have cleaned changed the dust filter Clean the dust filter under warm running water Wait until the filter is completely dry or Dispose of the dust filter if defective 6 3 Removing the thermal accumulat...

Page 18: ...t you can reach both cables Ensure that the fan s side WITHOUT type plate is directed to the interior room side Place inVENTron on an even surface Remove the first guiding vane from the fan Step 1 Carefully bend the lateral strips on the guiding vane away from the fan one after the other Hold the first removed strip in the current position with one hand until the guiding vane is completely removed...

Page 19: ...tion class DIN EN 61140 III Type of protection DIN EN 60529 IP20 Filter class standard filter DIN EN 779 2012 G4 Air flow sensitivity at 20 Pa DIN EN 13141 8 S3 Frost protection Automatically due to push pull operation bis 20 C Weight g Max 3 850 Wall thickness incl plaster render mm 140 Wall opening mm Ø 180 Wall sleeve Ø 160 Conformity 7 2 Label according to EC Directive for energy related produ...

Page 20: ...de one direction devices only no s Internet www inventer de t Airflow sensitivity 29 3 u Indoor and outdoor air tightness m h n a v Annual electricity consumption kWh m a 0 76 w Annual heating saved kWh m a cold 83 39 average 42 63 warm 19 28 iV Compact manual control Product fiche iV Compact according to VO 1254 2014 EU dated 2014 07 11 Pt Description Data a Supplier s name inVENTer GmbH b Suppli...

Page 21: ... 223x223 white 1505 0036 inner cover Flair V 223x233 white incl sound insulation SDE 1505 0037 9 Accessories and spare parts Accessories Component Order number Dust filter G4 IC Flair V 233x233 2 x 1004 0175 Pollen filter IC Flair V 233x233 2 x 1004 0143 Carbon filter IC Flair V 233x233 2 x 1004 0158 Sound absorbing insert R D160 1004 0148 Sound protector SPR R D160 1004 0154 Wind protection inser...

Page 22: ...eeve as far as the joint tape Fan speed very high Set a lower output level on the controller Supply air is cold Installation error Make sure that the type plate on the Xenion fan is directed towards the heat accumulator Check the connector plug on the control ler The connector plug must be sitting firmly in the connector housing The controller is operating in continuous ventilation mode Select hea...

Page 23: ...her information about the warranty is available at www inventer eu warranty 12 Service Claims Check the delivery for completeness and transport damage upon receipt using the delivery note Report missing items immediately and at the latest within 14 days to your supplier distributor or factory representative Warranty and guarantee claims In the case of a warranty or guarantee claim contact your loc...

Page 24: ...pe Action A Inner cover Filter Inner cover Cleaning Filter Check clean or change if necessary depending on filter type Filter Check clean or change if necessary depending on filter type B Thermal accumulator Xenion reversible fan guiding vanes Wall sleeve Cleaning C Accessories Check clean or change if necessary COMPANY DETAILS PUBLISHER INVENTER GMBH ORTSSTRASSE 4A D 07751 LÖBERSCHÜTZ GERMANY TEL...

Page 25: ... inventer eu Version dated 04 2019 Subject to modifications Item number 5006 0005 inVENTer GmbH 2014 19 inVENTer GmbH Ortsstraße 4a D 07751 Löberschütz 49 0 36427 211 0 49 0 36427 211 113 info inventer de ...