background image

6   INSPECTION AND TROUBLESHOOTING

Part No. 1167457

35

Invacare

®

 TheraPure™ Side Entry Whirlpool Tubs

DATE

MAINTENANCE PERSON

TYPE OF MAINTENANCE PERFORMED

NOTES

Summary of Contents for TheraPure 3602GXL

Page 1: ...anual EN This manual MUST be given to the user of the product BEFORE using this product read this manual and save for future reference Invacare TheraPure Side Entry Whirlpool Tubs Model 3602GXL Model...

Page 2: ...y Information 6 3 OVERVIEW 8 Features 8 Product Labeling 10 Typical Product Parameters 11 Minimum Floor Space and Clearance Requirements 12 Dimensions 14 4 INSTALLATION 16 Preparing the Work Area 16 E...

Page 3: ...Cleaning and Disinfecting 23 Opening Closing the Tub Door 26 Shoulder and Waist Straps 27 Water Temperature Setting 28 Filling the Tub 29 Using the Shower Massage Wand 29 Using the Whirlpool Function...

Page 4: ...an imminently hazardous situation which if not avoided will result in death or serious injury WARNING Warning indicates a potentially hazardous situation which if not avoided could result in death or...

Page 5: ...r consent C O D shipments will be refused please prepay shipping charges LIMITATIONS AND EXCLUSIONS THE WARRANTY SHALL NOT APPLY TO PROBLEMS ARISING FROM NORMAL WEAR OR FAILURE TO ADHERE TO THE ENCLOS...

Page 6: ...ally designed and manufactured for use in conjunction with Invacare accessories Accessories designed by other manufacturers have not been tested by Invacare and are not recommended for use with Invaca...

Page 7: ...temperature of 98 6 F The symptoms of hyperthermia include an increase of the internal temperature of the body dizziness lethargy drowsiness and fainting The tub is specifically designed to be used w...

Page 8: ...de Entry Whirlpool Tubs 8 Part No 1167457 3 Overview 3 1 Features Whirlpool On Off Button Fill Button Push in once to auto fill push in and hold to add additional water to tub Water Temperature Thermo...

Page 9: ...RVIEW Part No 1167457 9 Invacare TheraPure Side Entry Whirlpool Tubs Whirlpool Jet Shower Massage Wand Overflow Fill Spout Adjustment for angle of wand in cradle Flow Control Valve Shower Spray Adjust...

Page 10: ...RVIEW Invacare TheraPure Side Entry Whirlpool Tubs 10 Part No 1167457 3 2 Product Labeling Model 3652G Models 3602GXL Labels located inside the Cabinet Door Cabinet Door Label located on interior hard...

Page 11: ...s 7 feet x 6 feet Exterior Length Interior Length 72 inches 56 inches 67 inches 56 inches Exterior Width Interior Seat Width 34 inches 23 inches 32 inches 26 inches Overall Height Rim Height 42 75 inc...

Page 12: ...art No 1167457 3 4 Minimum Floor Space and Clearance Requirements Model 3602GXL Tub is shown with Model 1900 Traverse lift 12 80 TO 98 6 to 24 40 MIN Allow for a 40 door swing 12 9 36 MIN MINIMUM TUB...

Page 13: ...raPure Side Entry Whirlpool Tubs Model 3652G Tub is shown with Model 1900 Traverse lift 12 6 to 24 38 5 12 8 5 36 MIN MINIMUM TUB CLEARANCE 76 5 to 94 5 36 A l l o w f o r a 3 8 5 d o o r s w i n g 9...

Page 14: ...ft side of tub 5 5 140 mm up from floor 3 4 Cold water stub with recommended shut off valve D 16 5 419 mm inside of the door 2 Drain floor drain recommended E 27 686 mm from left side of tub 14 355 mm...

Page 15: ...4 Cold water stub with recommended shut off valve D 4 102 mm from left inside wall 5 127 mm from front inside wall of tub 2 Drain floor drain recommended E 4 875 124 mm from centerline 9 229 mm up fro...

Page 16: ...ub Otherwise injury or damage may occur Access for servicing the tub MUST be provided Install the tub in a location that will permit access to the service panels plumbing and electrical hookups CAUTIO...

Page 17: ...ub For installation details refer to Refer to Electrical Installation on page 19 and Plumbing Installation on page 20 For dimensions refer to Dimensions on page 14 Electrical Line Routing Hole Cold Wa...

Page 18: ...ng the Tub 1 Level the tub by adjusting the telescopic legs either up or down using a wrench to arrive at the desired height 2 Check to make sure the tub is level by placing a level on the front and s...

Page 19: ...rcuit that is protected by a ground fault circuit interrupter GFCI Such a GFCI should be provided by the installer and should be tested on a routine basis To test the GFCI push the test button The GFC...

Page 20: ...tion of tub Refer to Operating Instructions on page 22 DANGER Be certain all plumbing work is performed by a qualified plumber and is in compliance with local codes WARNINGS Be certain all plumbing wo...

Page 21: ...r line is protected by a 15 AMP GFCI All water lines are checked for leaks ICCI skin care and cleaning products have been ordered To place your order call 800 668 2337 ICCI representative has been cal...

Page 22: ...ARE SUPERVISED AT ALL TIMES Recommended length of time spent in a bath is 5 to 10 minutes However if you or the person you are caring for becomes nauseated or dizzy or the person develops a headache...

Page 23: ...he seal This will prolong the life of the door seal 5 2 Cleaning and Disinfecting WARNINGS Clean and disinfect the tub after EACH use to avoid resident infection and contamination of the tub DO NOT cl...

Page 24: ...ut the straps into the bottom of the tub 4 Clean the pieces and spray all surfaces of the tub with Dispatch Cleaner and Disinfectant Take a long handled brush and thoroughly clean the interior surface...

Page 25: ...handled soft brush or similar product to wipe down all surfaces and allow the heavy duty cleaner to remain in contact with the exposed surfaces for approximately ten minutes Rinse off surfaces using t...

Page 26: ...pen the door Closing the Tub Door 1 Close the door 2 Push down on the door handle to lock the door into position 3 Lift the door handle to ensure the safety pin has engaged the door properly 4 If the...

Page 27: ...eft arm pit and around the resident Secure the ends together with the plastic clasp 2 Bring both ends of the waist strap around the resident Secure the ends together with the plastic clasp 3 Adjust th...

Page 28: ...the body reaches a level several degrees above the normal body temperature of 98 6 F The symptoms of hyperthermia include an increase in the internal temperature of the body dizziness lethargy drowsi...

Page 29: ...urning the flow control 4 Adjust the shower spray by rotating the shower wand head 5 Turn the shower massage off by pressing the ON OFF button again DANGER RISK OF SCALDING Check that the water temper...

Page 30: ...er use press the whirlpool button again to stop the whirlpool jets 4 Drain the tub completely 5 Transfer the resident from the tub 6 Clean and disinfect the tub including the door seal Refer to Cleani...

Page 31: ...safety pin properly engages the door Check that all labels are present and legible Replace if necessary Before Each Use Clean and Disinfect the tub Refer to Cleaning and Disinfecting on page 23 Ensur...

Page 32: ...Water deposits in whirlpool jets Disassemble and clean whirlpool jets System is noisy Whirlpool jets are turned on without water completely covering the jet assemblies Turn off the whirlpool jets Add...

Page 33: ...6 INSPECTION AND TROUBLESHOOTING Part No 1167457 33 Invacare TheraPure Side Entry Whirlpool Tubs 6 3 Maintenance Record DATE MAINTENANCE PERSON TYPE OF MAINTENANCE PERFORMED NOTES...

Page 34: ...6 INSPECTION AND TROUBLESHOOTING Invacare TheraPure Side Entry Whirlpool Tubs 34 Part No 1167457 DATE MAINTENANCE PERSON TYPE OF MAINTENANCE PERFORMED NOTES...

Page 35: ...6 INSPECTION AND TROUBLESHOOTING Part No 1167457 35 Invacare TheraPure Side Entry Whirlpool Tubs DATE MAINTENANCE PERSON TYPE OF MAINTENANCE PERFORMED NOTES...

Page 36: ...tenpermission fromInvacare Trademarks are identified by and All trademarks are owned by or licensed to Invacare Corporation or its subsidiaries unless otherwise noted Dispatch is a registered trademar...

Reviews: