Invacare Flo-tech Contour Visco User Manual Download Page 9

Invacare 

Flotech®

 

Contour Visco

Technical data

9

8  Technical data

8.1  General data

Product

Total 

Height 

[mm]

Total 

Width 

[mm]

Total 

Depth 

[mm]

Nominal 

density range 

[kg/m

3

]

Nominal 

hardness 

range [N]

Minimum / 

maximum user 

weight [kg]

Product-

weight 

[kg] 

1)

Flo-tech® Contour 

Visco medium

120

360 – 430 330 – 430

80 – 90

140 – 160

40 – 75

1.6

Flo-tech® Contour 

Visco firm

120

360 – 510 330 – 530

80 – 90

180 – 200

50 – 100

1.6

Flo-tech® Contour 

Visco very firm

120

360 – 510 330 – 530

80 – 90

240 – 260

80 – 125

1.6

1)

 Weights can vary depending on size of cushion ordered, average weights used as     

   an indication.
Local requirements / certification available upon request from Invacare.

8.2  Material

Viscoelastic foam

Polyurethane foam components

HR foam

Polyurethane foam components

Black cover

Knitted polyamide, coated with an anti-microbial poly-

urethan coating. Substrate treated with a flurocarbon 

to give water/stain resistance.

Platilon cover

Polyurethane Ether

All cushion components are Latex-Free.

8.3  Contour Visco Warranty

Warranty : 3 years

This warranty applies against manufacturing defects under normal use of the 

cushion.

 CAUTION : The warranty is only valid if the dealer has properly fulfilled 

this warranty certificate with date of sale, dealer stamp and cushion number.

Date of sale:

Vendor‘s stamp

N

o

Sticker

Summary of Contents for Flo-tech Contour Visco

Page 1: ...Invacare Flo tech Contour Visco This manual MUST be given to the user of the product BEFORE using the product read this manual and save it for future reference EN Cushion User Manual...

Page 2: ...ymbols on the product 5 3 Description 5 3 1 Product description 5 4 Usage 6 4 1 Safety information 6 4 2 Using the cushion 6 5 Transport 6 5 1 Safety information 6 6 Maintenance 6 6 1 Inspection 6 6 2...

Page 3: ...ded CAUTION Indicates a hazardous situation that could result in minor or slight injury if it is not avoided IMPORTANT Indicates a hazardous situation that could result in damage to property if it is...

Page 4: ...expectancy of three years for these products provided they are used in strict accordance with the intended use as set out in this document and all maintenance and service requirements are met The est...

Page 5: ...s Drip cables stents and other foreign objects must not become entrapped between the user and the pressure reducing surface of the cushion IMPORTANT The information contained in this document is subje...

Page 6: ...ntal cover damage please ensure that sharp objects are not placed on the cover When using patient transfer aids care should be taken not to damage the Flotech cover All transfer aids should be checked...

Page 7: ...umble dry for longer than 10 minutes Dry covers thoroughly before re fitting to the Flotech product Disinfecting black covers Reducing the number of microorganisms Please contact your hygiene speciali...

Page 8: ...a protective cover box Store cushions in a flat state on clean dry off flooring free from sharp edges to avoid any possible damage Never store other items on top of a cushion Do not store cushions nex...

Page 9: ...ights used as an indication Local requirements certification available upon request from Invacare 8 2 Material Viscoelastic foam Polyurethane foam components HR foam Polyurethane foam components Black...

Page 10: ...Invacare Flotech Contour Visco Technical data 10 8 4 Certificates of conformity...

Page 11: ...Invacare Flotech Contour Visco Technical data 11...

Page 12: ...Invacare Flotech Contour Visco Technical data 12...

Page 13: ...3 0 2 47 42 12 24 contactfr invacare com www invacare fr Invacare distributeur Invacare UK Operations Limited Pencoed Technology Park Pencoed Bridgend CF35 5AQ United Kingdom Tel 44 0 1656 776222 Fax...

Reviews: