PLEASE READ ALL WARNINGS/CAUTIONS BEFORE USE

 

·

 

DO NOT

or explosive gases.

 

·

 

equipment other then nasal or masked type.

 

·

  When using nasal or masked type administering equipment, 

oxygen or air tubing 

MUST

 be routed and secured properly to 

ensure that tubing does 

NOT

 become entangled and eventually 

severed during normal operation of  Electric bed

.

 

·

  Liquids can cause electrical hazards. In the event of a spill in or 

around the bed, immediately unplug the bed and allow the area 

to dry thoroughly before plugging in the bed. If a spill occurs, 

UNPLUG

 the bed immediately. Clean up spill and allow bed or 

area to dry thoroughly before using the electric controls again.

 

·

  This bed is designed for adults only. 

DO NOT

 use with or for 

children. Children must be closely supervised at all times when near 

the bed.

·

  Users who are unable to understand or follow these instructions 

and warnings or who have limited physical capabilities should be 

supervised or assisted while using the bed.

·

 

NEVER PERMIT ANY ONE UNDER THE BED AT ANYTIME

.

 

·

  When operating or moving the bed, 

ALWAYS

 ensure that the 

individual utilizing the bed is positioned properly within the 

 

·

 

ALWAYS

 keep clear of moving parts when adjusting the bed. 

Patient should be centered on the bed with extremities within the 

mattress area. 

DO NOT

 allow extremities to extend beyond the 

sides or between bed rails.

WARNINGS

.

 

·

 

DO NOT

 use this bed for patient transport. 

DO NOT

 move the bed 

while occupied, otherwise injury or damage may result.

·

  The maximum safe working load of this bed (patient, mattress, 

bedding, and accessories) is 450lbs/204kg. The maximum user weight is 

350lbs/158kg. 

ALWAYS

 observe the weight limits.

·

 

DO NOT

 stand or climb on bed.

·

  Bed is intended for a single occupant. 

NEVER

 allow more than one 

person to sit or lay on bed at the same time.

·

  To prevent patient injury due to falls, 

ALWAYS

 leave bed at lowest height 

when the patient is unattended.

·

  Inappropriate handling of the power cord can create an electrical hazard.

   

Regularly inspect cord and plug for damage such as kinking 

 

or fraying; 

DO NOT

 use if cord or plug is damaged, contact   

 

your dealer for repair or replacement.

   

DO NOT

 unplug by pulling on the cord, this may damage 

 

the plug connection. 

NEVER

 pull, jerk, twist, or severely 

 

bend the cord, especially near the plug connection.

   

DO NOT

 use this product with power strips or extension cords. 

 

DO NOT

 overload wall outlets. 

ALWAY

S connect this product to an  

 

appropriate voltage outlet; 

DO NOT

 use with a DC to AC converter.

·

 

ALWAYS

 take care when routing power cords for accessories or other 

equipment through the space under the bed. Cords should be secured 

such that they cannot become pinched or damaged by moving parts of 

the bed. Damaged cords should 

NOT

 be used.

·

  It is the responsibility of the patient’s physician and caregiver to assess 

the patient and determine which devices and accessories are needed 

to support and protect the patient, while limiting risk to the patient. 

Use of fall protection, pressure management, and transfer assistance 

mechanisms should be considered as appropriate.

·

 

DANGER!

 Entrapment may cause patient injury or death.

warnings continued on next page

Summary of Contents for 5410VC

Page 1: ...Full Electric Value Care Bed User Manual Entrapment Guide For use with Item s 5410VC 5410VCDECK 5410VCHFB...

Page 2: ...ant Operation 14 Head Footboard Optional Height Adjustment 15 Maintenance and Safety Checks 15 Electronics 15 Bed Frame and Sleeping Surface 15 Cleaning 15 Lubrication and Mechanical 15 Notice Indicat...

Page 3: ...may result The maximum safe working load of this bed patient mattress bedding and accessories is 450lbs 204kg The maximum user weight is 350lbs 158kg ALWAYS observe the weight limits DO NOT stand or c...

Page 4: ...2 away from any direct heat source Make sure head and foot springs sections are connected securely to the bed ends before use DO NOT use the bed to transport a person in or on the bed Otherwise injury...

Page 5: ...plug the power cord from the junction box Damage to cord will result Use caution when disconnecting the pendant DO NOT press pendant buttons When bed is not to be used for an extended period unplug el...

Page 6: ...ng B Head Spring C Head Board D Foot Board E Hi Low Shaft F Locking Pins 4 G Motor H Hand Crank attached to foot board for shipping I Casters 4 2 locking 2 non locking J Spring Clips 2 K Hand Pendant...

Page 7: ...e h t e d i l S catches the rivet on the foot section Position head wing as shown h c a e o t n i n i p k c o l e m a r f a l l a t s n i l e v e l s n o i t c e s o w t e h t h t i W Be sure to prop...

Page 8: ...ve shaft through hanger bracket Install Hi Low drive shaft to the Hi Low motor located on the foot section Insert the spring loaded side of the drive shaft into the lower receptacle as shown ASSEMBLY...

Page 9: ...h bed on side extend the drive shaft until it reaches the full length of bed The drive shaft adjustment holes are marked for either semi or full beds Choose the full bed hole ASSEMBLY INSTRUCTIONS Fig...

Page 10: ...ALWAYS install locking casters diagonally from each other Attach the head board and foot boards ALWAYS ensure that the 2 hooks on each side of the head and foot boards are fully engaged and seated sec...

Page 11: ...spring loaded drive shaft on the hi low motor and insert the drive shaft into the gear box located on the footboard Make sure the slot on the spring loaded drive shaft fully engages the roll pin on t...

Page 12: ...ow motor cables into motor as shown Connect a 9V battery not included to the battery clip located on the motor The battery clip is located in a recess under the motor cover With a charged battery inst...

Page 13: ...towards the bed and lock on the actuator rod Repeat for foot section After the motor is fully installed slide both locking covers back onto the motor Once fully assembled and checked plug the unit in...

Page 14: ...eration has been used to lower the bed Hand Crank The full electric bed is equipped with a removeable manual hand crank that may be used when either electric or battery power is unavailable WARNING AL...

Page 15: ...ection Main Frame Check joints between sleeping surface sections for loose fasteners Cleaning The metal parts of the bed are covered with a baked epoxy coating Clean all coated parts with mild deterge...

Page 16: ...ard panel frame a Headboard gear assembly b Footboard dear assembly 6 Sleep surface hook 7 Motor brackets 8 Hi Low motor gearbox 9 Caster set 2 locking 2 non locking 10 Caster receptacle 11 Frame link...

Page 17: ...ars All other parts 3 year This device was built to exacting standards and carefully inspected prior to shipment This Limited Warranty is an expression of our our assurance to the end user of years of...

Page 18: ...DL18 300UM A 2020 04 13 2020 Hangzhou Dunli Medical Instruments Co Ltd No 1 Dunli Road Renhe Street Yuhang Hangzhou Zhejiang 311107 China...

Reviews: