![INTORQ BFK458 Translation Of The Original Operating Instructions Download Page 43](http://html1.mh-extra.com/html/intorq/bfk458/bfk458_translation-of-the-original-operating-instructions_2081634043.webp)
Commissioning and operation
Kendrion INTORQ | BA 14.0225 | 05/2022
43
7.2.3
Testing the hand-release functionality
NOTICE
This operational test must also be carried out!
Fig. 27:
Turning direction of the lever
Size
Hand force [N]
Standard braking torque
Hand force [N]
Maximum braking torque
06
20
30
08
35
50
10
55
75
Tab. 15:
Actuating forces
1. Make sure that the motor and brake are de-energized.
2. Pull (with some force) on the lever until the force increases sharply.
– The rotor must now rotate freely. A small residual torque is permissible.
NOTICE
¾
Make sure that the brake it not subject to excessive force.
¾
Do not use auxiliary tools (e.g. extension pipes) to facilitate the air release. Auxiliary
tools are not permitted and are not considered as proper and intended usage.
3. Release the lever.
– A sufficient torque must build up immediately!