10. Use a torque key to retighten the supplied fixing screws (10) with the required
tightening torque,
16.
11. Switch off power.
4.5.3
Checking the air gap
BFK455-007.iso/dms
Fig. 17 Checking the air gap
12. Check the air gap by means of a feeler gauge and correct it if necessary
(s
LN
= 0.4 +0.05mm), according to Fig. 10 and Fig. 11.