background image

128

GS

SAVE THESE INSTRUCTIONS

Page 3

(128GS)  MODEL SF20220R SAND FILTER PUMP  ENGLISH  7.5” X 10.3”  PANTONE 295U  10/28/2011

English

SS

AA

FF

EE

TT

YY

 RR

UU

LL

EE

SS

WARNING

IMPORTANT SAFETY RULES

Read, Understand and Follow All Instructions Carefully Before Installing and Using this Product.

READ AND FOLLOW ALL INSTRUCTIONS

• To reduce the risk of injury, do not permit children to use this product. Always 

supervise children and those with disabilities.

• Children must stay away from this product and electrical cord(s).
• Children should be supervised to ensure that they do not play with the appliance.
•  This appliance is not intended for use by persons (including children) with reduced 

physical, sensory or mental capabilities, or lack of experience and knowledge. They 
must at all times be supervised by a knowledgeable and experienced adult 
responsible for their safety.

• Assembly and disassembly by adults only.
• Risk of electric shock. Connect this product only to a grounding type receptacle 

protected by a ground-fault circuit interrupter (GFCI) or residual current device 
(RCD). Contact a qualified electrician if you cannot verify that the receptacle is 
protected by a GFCI/RCD. Use a qualified electrician to install the GFCI/RCD, 
which has a maximum rate of 30mA. Do not use a portable residual current device 
(PRCD).

• Always unplug this product from the electrical outlet before removing, cleaning, 

servicing or making any adjustment to the product.

•  The plug must be accessible after produc   t is installed.
• Do not bury the electrical cord. Locate the cord where it will not be damaged by 

lawn mowers, hedge trimmers and other equipment.

• If the supply cord is damaged, it must be replaced by the manufacturer, its service 

agent or similarly qualified persons in order to avoid a hazard.

• To reduce the risk of electric shock, do not use extension cords, timers, plug 

adaptors or converter plugs to connect unit to electric supply; provide a properly 
located outlet.

• Do not attempt to plug in or unplug this product while standing in water or when 

your hands are wet.

• Keep this product more than 2m away from the pond.
• Keep the plug of this product more than 3.5m away from the pond. 
• Position this product away from the pond, so as to prevent children from climbing 

on it and accessing the pond.

• Do not operate this product when pond is occupied.
• To reduce the risk of entrapment hazard, never enter the pond if suction strainer 

component is loose, broken, cracked, damaged or missing. Replace loose, broken, 
damaged, cracked or missing suction strainer components immediately.

• Your body or hair may be trapped causing permanent injury or drowning.
• To prevent equipment damage and risk of injury, always turn pump off before 

changing the filter control valve position.

• Never operate this product above the maximum working pressure stated on the 

filter tank.

• Hazardous Pressure. Improper tank valve cover assembly could cause the valve 

cover to blow off and cause serious injury, property damage or death.

• This product is intended to be used only for the purposes described in the manual!

FAILURE TO FOLLOW THESE WARNINGS MAY RESULT IN
PROPERTY DAMAGE, ELECTRIC SHOCK, ENTANGLEMENT OR
OTHER SERIOUS INJURY OR DEATH.

These product warnings, instructions and safety rules provided with the product represent
some common risks of water recreation devices and do not cover all instances of risk and 
danger. Please use common sense and good judgement when enjoying any water activity.

Summary of Contents for SP20220

Page 1: ...roits réservés Todos los derechos reservados Alle Rechte vorbehalten Printed in China Imprimé en Chine Impreso en China Gedruckt in China Trademarks used in some countries of the world under license from Marques utilisées dans certains pays sous licence de Marcas registradas utilizadas en algunos países del mundo bajo licencia de Warenzeichen verwendet in einigen Ländern der Welt in Lizenz von Int...

Page 2: ...NTONE 295U 10 28 2011 English T T A A B B L L E E O O F F C C O O N N T T E E N N T T S S Warnings 3 Parts List References 4 6 Setup Instructions 7 11 Product Specifications 7 Operating Instructions 12 14 Maintenance 15 Troubleshooting Guide 16 Limited Warranty 17 Intex Service Center Locations 18 ...

Page 3: ...quipment If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard To reduce the risk of electric shock do not use extension cords timers plug adaptors or converter plugs to connect unit to electric supply provide a properly located outlet Do not attempt to plug in or unplug this product while standing in water...

Page 4: ...0220R SAND FILTER PUMP ENGLISH 7 5 X 10 3 PANTONE 295U 10 28 2011 English P P A A R R T T S S L L I I S S T T PARTS LIST NOTE Drawings for illustration purpose only Actual product may vary Not to scale 7 1 9 4 5 2 6 3 8 10 11 13 14 15 16 17 18 19 12 20 21 ...

Page 5: ...LTER PUMP ENGLISH 7 5 X 10 3 PANTONE 295U 10 28 2011 English PARTS LIST continued NOTE Drawings for illustration purpose only Actual product may vary Not to scale 23 25 22 24 26 27 28 29 30 31 32 33 34 Optional Optional Optional 35 P P A A R R T T S S L L I I S S T T ...

Page 6: ... P A A R R T T S S R R E E F F E E R R E E N N C C E E PARTS REFERENCE Before assembling your product please take a few minutes to check the contents and become familiar with all the parts NOTE Drawings for illustration purpose only Actual product may vary Not to scale 1 5 9 11 2 13 35 19 3 6 7 4 15 16 17 11 18 8 10 14 36 37 38 ...

Page 7: ... RING 4 11228 12 HOSE WITH NUTS 2 11010 13 SAND FILTER INTERCONNECTING HOSE 1 11535 14 LEAF TRAP NUT 1 11479 15 LEAF TRAP O RING 1 11232 16 BASKET 1 11260 17 FILTER HOUSING NUT 1 11261 18 L SHAPE O RING 1 11412 19 SEDIMENT RELEASE VALVE 1 10460 20 VALVE O RING 1 10264 21 PLUNGER VALVE HOSE O RING STEP WASHER INCLUDED 2 10747 22 HOSE O RING 2 10262 23 STEP WASHER 2 10745 24 STRAINER NUT 2 10256 25 ...

Page 8: ...s a specialized area and you should consult your local pond service specialist for details TOOLS REQUIRED One 1 Phillips screwdriver Pump location and mounting The system must be installed on a solid level and vibration free base Provide a location protected from the weather moisture flooding and freezing temperature Provide adequate access space and lighting for routine maintenance Pump motor req...

Page 9: ...ly unit to the tank support base See drawing 5 2 NOTE Ensure the pre filter housing water inlet hose connection is facing towards the pond IMPORTANT Some countries especially in the European community require the product to be secured to the ground or to a base in a permanent upright position Check your local authorities to determine if there is a regulation in your area regarding pond filter pump...

Page 10: ...e the sand shield 6 over the top of the center pipe Pour the sand into the tank at a slow rate see drawing 6 2 Fill the tank approximately half way remove the sand shield 6 from the top see drawing 7 3 Evenly distribute the sand inside the tank then fill the tank with some water to provide a cushioning effect when the remaining sand is poured in This prevents the center pipe hub 7 from excessive s...

Page 11: ...ith the motor outlet see drawing 11 S S E E T T U U P P I I N N S S T T R R U U C C T T I I O O N N S S SETUP INSTRUCTIONS continued WARNING Improper tank valve and clamp assembly could cause the valve and clamp to blow off and cause serious injury property damage or death 11 WATER INLET WATER OUTLET 2 Place an L shape o ring 11 on the 6 way valve inlet connection and on the pump motor outlet In a...

Page 12: ...r Ensure the hose nuts are securely tightened 2 Connect the second hose between the 6 way valve water outlet and the upper plunger valve with the inlet nozzle Ensure the hose nuts are securely tighten 3 The third hose connection port drain waste outlet on the 6 way valve shall be directed to a proper draining receptacle using a hose or pipe not provided Remove the drain cap before attaching the dr...

Page 13: ...ter Flow Direction FILTER see drawing 14 Normal filtration and regular vacuuming of pond From pump through filter media to pond BACKWASH see drawing 15 Reverses water flow to clean filter media From pump through filter media to valve waste drain outlet RINSE see drawing 16 For initial startup cleaning of the sand and leveling the sand bed after backwashing From pump through filter media to valve w...

Page 14: ... drawings 15 20 IMPORTANT To prevent damage to the 6 way valve always depress the valve handle before turning Always switch off pump before changing the 6 way valve position 4 Switch on the pump see drawing 21 Water is circulating backward through the sand media and to waste drain outlet Backwash until a clear flow of water is observed in the waste drain outlet or through the drain sediment window...

Page 15: ... flow to diminish If there is no vacuuming device attached to the system and the pressure gauge reading is in the yellow zone it is time to backwash the sand media see BACKWASH under initial startup and operation section Vacuuming device i e Intex auto pond cleaner attached to the system may also cause the flow to diminish and the pressure to rise Remove any vacuuming device from the system and ch...

Page 16: ... on the lower side of the pre filter housing see drawing 23 3 In a counter clockwise motion unscrew the leaf trap cover 14 then remove the basket 16 and leaf trap o ring 15 from the pre filter housing see drawing 24 4 Empty and flush the basket using a garden hose may use a plastic brush to remove deposits from the basket Do not use metal brush 5 Clean and rinse the inside of the pre filter housin...

Page 17: ...handle and rotate so as to set the pointer on the valve top N position This allows the water to drain from the valve Leave the 6 way valve in this inactive position 7 It is best to place all dry pieces and pump motor in the original packaging for storage To avoid condensation or corrosion problem do not cover or wrap pump motor with plastic bags 8 Store the pump motor and accessories in a dry plac...

Page 18: ...ions in the intake by unscrewing it from the 6 way valve Contact Intex service center Use only No 20 silica sand with particle size range 0 45 to 0 85 mm 0 018 to 0 033 inches and a Uniformity Coefficient less than 1 75 Change sand FILTER MOTOR FAILS TO START FILTER DOESN T CLEAN POND FILTER DOESN T PUMP WATER OR FLOW IS VERY SLOW PUMP DOESN T WORK 6 WAY VALVE COVER LEAKING HOSE LEAKING TIMER IS I...

Page 19: ... contact the appropriate Intex Service Center listed in this manual The Service Center will determine the validity of the claim IMPLIED WARRANTIES ARE LIMITED TO THE TERMS OF THIS WARRANTY AND IN NO EVENT SHALL INTEX THEIR AUTHORIZED AGENTS OR EMPLOYEES BE LIABLE TO THE BUYER OR ANY OTHER PARTY FOR DIRECT OR CONSEQUENTIAL DAMAGES OR LIABILITIES Some countries or jurisdictions do not allow the excl...

Page 20: ... ANTONIO SÃO PAULO SP BRASIL TEL 55 11 5181 4646 FAX 55 11 5181 4646 E mail sacintexbrasil uol com br ISRAEL ALFIT TOYS LTD MOSHAV NEHALIM MESHEK 32 49950 ISRAEL TEL 972 3 9076666 FAX 972 3 9076660 E mail michald chagim co il ASIA INTEX DEVELOPMENT CO LTD 9TH FLOOR DAH SING FINANCIAL CENTRE 108 GLOUCESTER ROAD WANCHAI HONG KONG TEL 852 28270000 FAX 852 23118200 E mail xmservicesupport intexcorp co...

Reviews: