OPERATING INSTRUCTIONS
Valve Position
Function
Water Flow Direction
FILTER
(see drawing 25)
Normal filtration and regular vacuuming
of pool
From pump through filter media to
pool
BACKWASH
(see drawing 26)
Reverses water flow to clean filter
media
From pump through filter media to
valve waste/drain outlet
RINSE
(see drawing 27)
For initial startup cleaning of the sand, and
leveling the sand bed after backwashing
From pump through filter media to
valve waste/drain outlet
WASTE
(see drawing 28)
For vacuuming directly to waste,
lowering pool level or to drain the pool
From pump to valve waste/drain
outlet bypassing the filter media
RECIRCULATE
(see drawing 29)
For circulating water back to pool
without going through the filter media
From pump through valve to pool
bypassing the filter media
CLOSED
(see drawing 30)
Shuts off all flow to filter and pool
“Do not use this setting with pump running”
6-way valve positions and function:
• Risk of electric shock. Connect this product only to a grounding type receptacle protected
by a ground-fault circuit interrupter (GFCI) or residual current device (RCD). Contact a
qualified electrician if you cannot verify that the receptacle is protected by a GFCI/RCD.
Use a qualified electrician to install the GFCI/RCD, which has a maximum rate of 30mA.
Do not use a portable residual current device (PRCD).
•
To reduce the risk of electric shock, do not use extension cords, timers, plug adaptors or
converter plugs to connect unit to electric supply; provide a properly located outlet.
•
Do not attempt to plug in or unplug this product while standing in water or when your
hands are wet.
• Never operate this product above the maximum working pressure stated on the filter tank.
• Always switch off pump before changing the 6-way valve position.
• Operating this product without water flowing through the system can cause a build up of
hazardous pressure which can result in an explosive situation, serious injury, property
damage or death.
• Never test this pump with compressed air. Never operate the system with water
temperature above 35°C (95°F).
WARNING
RESET
RESET
TEST
TEST
23
RESET
RESET
RESET
TEST
TEST
24
TEST
RCD OPERATING INSTRUCTIONS
• Plug RCD into power outlet. Press RESET button on the RCD plug. Indicator
should be "ON". See FIG. 23.
• Press TEST button on the RCD plug. Indicator should be "OFF". See FIG. 24.
• Press RESET button for use. Do not use if test fails. Contact a qualified
electrician to determine cause of failure.