Spa Control Unit Installation

1.

  Connect the spa control unit to the spa tub 

(see drawing 15)

. Hand-tighten the connectors securely.    

Do not use tools to tighten.

2.

  Reinstall the back cover

 (2)

 to the spa control base 

(see drawing 16)

.

 

Back cover must be installed 

 

before using the SPA.

 CAUTION: 

Do not sit, lean, cover or place any objects over the spa control unit.

3.

 In

fl

 ate the spa tub 

fi

 rst before installing 

fi

 lter pump 

fi

 ttings. Attach  

the 

fi

 lter cartridge housing assembly to the lower outlet grid on the 

inside of the spa “A” side. Attach remaining 

fi

 lter cartridge housing 

assembly to the lower outlet grid on the inside of the “B” side 

(see 

drawing 17)

.

4.

 Before 

fi

 lling with water make sure the bottom drain valve caps are 

securely closed on the inside and outside on both sides of the tub.

5.

  Fill the spa tub with freshwater to a level between MIN and MAX    

marked on the inside of the spa wall. Do not over 

fi

 ll the spa. Never 

 

move the spa tub with water inside and/or with the control base 

 

attached to the spa as the spa or control base may be damaged. 

 

WARNING: 

Never pour water with a temperature higher than 

  40°C (104°F) into the spa directly. It is recommended to 

fi

 ll the spa tub with lukewarm water 

for quick heating and energy saving. Both sides of the tub must be 

fi

 lled with water to the 

recommended level.

6.

  Place the spa cover and spa air bladder (pre-installed in spa cover) over the spa tub, and make sure the  

spa cover buckles are locked using the key provided after pulling the buckled straps tight.

 

IMPORTANT:

 Inspect the spa cover regularly for leak, premature wear and tear or deterioration. Never 

 

use a damaged spa cover. 

7.

  Ensure the spa is plugged into a grounded electrical socket and press the 

 button to turn on the 

 

control unit panel buttons 

fi

 rst. Press the 

 button on the control panel to activate the heater, see “Spa 

 

Control Unit Panel” operation section.

17

16

2

15

Summary of Contents for PureSpa PS-BH-20

Page 1: ...echte vorbehalten Printed in China Imprim en Chine Impreso en China Gedruckt in China Trademarks used in some countries of the world under license from Marques utilis es dans certains pays sous licenc...

Page 2: ...TH POOL ENGLISH 7 5 X 10 3 PANTONE 295U 07 15 2016 English Page 2 Warning 3 5 Parts 6 7 Product specifications 8 Set up 8 12 Operation 13 14 LED Code Chart 15 Maintenance and Chemicals 16 22 Storage 2...

Page 3: ...ust contact the local service center for assistance and or repair of the product Parts containing live parts except parts supplied with safety extra low voltage not exceeding 12 V must be inaccessible...

Page 4: ...37 C 98 6 F The symptoms of hyperthermia include an increase in the internal temperature of the body dizziness lethargy drowsiness and fainting The effects of hyperthermia include failure to perceive...

Page 5: ...of SPA must be directly connected only to a earthed socket outlet from a fixed electrical installation To reduce the risk of electric shock do not use extension cords timers plug adaptors or converte...

Page 6: ...age 6 PARTS Before assembling your product please take a few minutes to check the contents and become familiar with all the parts NOTE Drawings for illustration purpose only Actual product may vary No...

Page 7: ...11696B 11 SPA DRAIN VALVE ADAPTOR 1 11718 11718 12 FILTER CARTRIDGE HOUSING 2 11798 11798 13 FILTER CARTRIDGE 4 11692 11692 14 FILTER CARTRIDGE HOUSING LID 2 11797 11797 15 INLET OUTLET PLUG 6 11739 1...

Page 8: ...moisture condensation Spa owners may need to comply with local or states laws relating to childproof fencing safety barriers lighting and other safety requirements Contact your local building code enf...

Page 9: ...ly 1 Connect the control panel 3 cable plug into the receptacle on top of the spa control base and screw in the plug cover firmly by hand see drawing 1 2 Screw the control panel bolts 4 with the provi...

Page 10: ...t to lock it see drawing 7 3 Unscrew the air valve cap to reveal the stem in the up position for inflation Insert the other end of the inflation hose 7 into the valve and turn to the right to lock it...

Page 11: ...rm to the touch but not hard see drawing 13 2 Disconnect the inflation hose 7 from the air blower inflation outlet and the valve 3 Replace the control base inflation cap 5 back close and recess the in...

Page 12: ...des of the tub 5 Fill the spa tub with freshwater to a level between MIN and MAX marked on the inside of the spa wall Do not over fill the spa Never move the spa tub with water inside and or with the...

Page 13: ...A is illuminated the following options are available During the heating process press the filter button for 3 seconds to switch the filtration function to the B side the heater will stop and the flame...

Page 14: ...he filtration system will automatically start The filtration system can be activated together with the bubble function When the indicator light B is illuminated and the heater is off press the filter...

Page 15: ...he button to heat up the water to the desired temperature If problem persists contact Intex Service center E95 Water temperature too high Turn off and unplug the control unit When the water has cooled...

Page 16: ...housing and replace the cartridge housing assembly back onto the spa tub wall 2 Change the spa water every 3 days See Spa Tub Drainage and Spa Tub Cleaning sections for details 3 Use spa chemicals to...

Page 17: ...ye skin irritation and destruction of total alkalinity Result if too high Scale formation cloudy water shorter filter heater runs eye skin irritation poor chlorine efficiency Total Alkalinity TA indic...

Page 18: ...ppm you can add sodium bisulfate or muriatic acid to the water drop by drop until the test strip indicates a 240 ppm reading then add 0 528 Lb 238 g of sodium bisulfate or 0 202 qt 192 ml of muriatic...

Page 19: ...ppm 350 ppm 250 ppm Desired level 100 ppm Water Volume Ratio Vhard water Vsoft water 1 9 1 4 2 5 2 3 Lowering Calcium Hardness Using Soft Water Raising pH Raising pH Using Sodium Bicarbonate Lowering...

Page 20: ...6 When the water stops draining disconnect the spa control unit from the spa tub wall Lift the spa tub wall from the side opposite the drain leading any remaining water to the drain and emptying the s...

Page 21: ...air valve base from the inside of the spa tub wall and turn the wrench 22 clockwise IMPORTANT Never adjust the air valve base when the spa is in use or filled with water Only use the air valve wrench...

Page 22: ...n is activated to avoid damage to the blower motor 4 Make sure all the spa components and accessories are thoroughly clean and dry before storage Air dry the spa tub in the sun for an hour before fold...

Page 23: ...cated circuit breaker feeding the spa electrical outlet only Contact a qualify electrician to correct the electrical fault Increase the temperature and attach the spa cover Clean or replace the filter...

Page 24: ...red by the provisions of the warranty the item will be repaired or replaced with the same or comparable item at Intex s choice at no charge to you Other than this warranty and other legal rights in yo...

Reviews: