WARNING

•  To reduce the risk of injury, do not permit children to use this product. Always supervise children 

  and those with disabilities.

•  Children must stay away from this product and all electrical cords.

•  Only for outdoor use.

•  Assembly and disassembly by adults only.

•  Not to energize or operate the unit if the appliance is damaged or improperly assembled.

•  Risk of electric shock. Connect only to a grounding type receptacle, this product is provided with a 

  ground-fault circuit interrupter. If replacement of the plug or cord is needed, use only identical 

  replacement parts.

•  Always unplug this product from the electrical outlet before removing, cleaning, servicing or making 

  any adjustment to the product.

•  The unit is provided with a ground-fault circuit interrupter (GFCI). To test the GFCI, push the test 

  button. The GFCI should interrupt power. Push the reset button, power should be restored. If the 

  GFCI fails to operate in this manner. The GFCI is defective. If the GFCI interrupts power to the pump 

  without the test button being pushed, a ground current is flowing, indicating the possibility of an 

  electric shock. Do not use this pump. Disconnect the pump and have the problem corrected by a 

  qualified service representative before using.

•  Do not bury the electrical cord. Locate the cord where it will not be damaged by lawn mowers, 

  hedge trimmers and other equipment.

•  To reduce the risk of electric shock, the supply cord cannot be replaced. If the cord is damaged, the 

  appliance should be replaced immediately.

•  To reduce the risk of electric shock, do not use extension cords, timers, plug adaptors or converter 

  plugs to connect unit to electric supply; provide a properly located outlet.

•  Do not attempt to plug in or unplug this product while standing in water or when your hands are wet.

•  Do not use an appliance leakage current interrupter (ALCI) in place of a GFCI since the ALCI will 

  not protect people.

•  Position this product away from the pool, so as to prevent children from climbing on it and accessing 

  the pool.

•  Make sure the electrical parameters indicated on the product correspond to the local mains voltage

  before you connect the unit.

•  This product is intended to be used only for the purposes described in the manual!

FAILURE TO FOLLOW THESE WARNINGS MAY RESULT IN PROPERTY 

DAMAGE, ELECTRIC SHOCK, ENTANGLEMENT OR OTHER SERIOUS 

INJURY OR DEATH.

IMPORTANT SAFETY RULES

Read, Understand and Follow All Instructions Carefully Before Installing and Using this Product.

READ AND FOLLOW ALL INSTRUCTIONS

For portable Above-Ground-Pools only

To ensure continued protection against shock hazard, use only identical replacement parts when 
servicing. This product is for use with storable pools only. Do not use with permanently-installed 
pools. A storable pool is constructed so that it is capable of being readily disassembled for storage 
and reassembled to its original integrity. A permanently-installed pool is constructed in or on the 
ground or in a building such that it cannot be readily disassembled for storage.
To reduce the risk of electric shock the pool must be installed no closer than 6 feet (1.8 m) from 
any electrical outlet. Do not place portable appliances closer than 5 feet (1.5 m) from the pool.

These product warnings, instructions and safety rules provided with the product represent some common 
risks of water recreation devices and do not cover all instances of risk and danger. Please use common 
sense and good judgement when enjoying any water activity.

CAUTION

Summary of Contents for Krystal Clear ZS6110

Page 1: ... Toys Airbeds and Boats available at fine retailers or visit our website Due to a policy of continuous product improvement Intex reserves the right to change specifications and appearance which may result in updates to the instruction manual without notice For illustrative purposes only IMPORTANT DO NOT RETURN PRODUCT TO STORE To purchase parts and accessories or to obtain non technical assistance...

Page 2: ...s Salt Table 9 Intex Pools Cyanuric Acid Table 10 Intex Pools Operating Time Table 11 Non Intex Pools Salt Table 12 Non Intex Pools Cyanuric Acid Table 12 Non Intex Pools Operating Time Table 12 Operating Instructions 13 14 LED Code Chart 15 Maintenance 16 18 Long Term Storage 18 Pool Maintenance and Chemical Definitions 19 Troubleshooting Guide 20 21 Control Station Replacement 22 General Aquatic...

Page 3: ...imers plug adaptors or converter plugs to connect unit to electric supply provide a properly located outlet Do not attempt to plug in or unplug this product while standing in water or when your hands are wet Do not use an appliance leakage current interrupter ALCI in place of a GFCI since the ALCI will not protect people Position this product away from the pool so as to prevent children from climb...

Page 4: ...duct may vary Not to scale When ordering parts be sure to quote the model number and part numbers REF NO DESCRIPTION QTY SPARE PART NO 1 ADAPTOR A WITH THREADED COLLAR 1 10849 2 L SHAPE O RING 2 11228 3 SCREW 2 11519 4 TITANIUM ELECTRODE NUT 1 11432 5 TITANIUM ELECTRODE 1 11374 6 O RING ON TITANIUM PLATES 1 11515 7 FLOW SENSOR 1 11460 8 CONNECTOR HOSE WITH THREADED FITTINGS 1 10720 9 ELECTROLYTIC ...

Page 5: ...110 120 Volt AC Amperage 1 1A Ideal Salt Level 3000 ppm parts per million Maximum sodium hypochlorite output hour 11 grams hour Ozone Output 150 mg hour Filter pump minimum flow rate 1600 4000 gallons hour 6056 15140 liters hour Limited Warranty see Limited Warranty Flow Sensor Electrolytic Cell Control Station Hose from Filter Pump Hose Returning Water to Pool ...

Page 6: ...te filter pump 1600 4000 gph 6056 15140 lph to drive the water and function properly The Ozone Saltwater System must be installed as the last piece of pool equipment in the water return line to the pool as displayed in Drawing 1 This location extends the life of the titanium plates 1 Go directly to step 2 if your pool is empty If your above ground pool is filled with water close the plunger valves...

Page 7: ...arge hose clamp Tighten securely Connecting the system to other types of pool After you have connected the Ozone Saltwater System to the pump connect it to the pool This is depicted in Drawings 1 Following are the common connection types Connection to 1 1 2 38mm connectors without thread 1 Connect the adaptor A 1 to the Ozone Saltwater System outlet Tighten securely 2 With the adaptor A 1 fixed to...

Page 8: ...ded The salt in the pool is constantly recycled Adding Salt 1 Switch the filter pump on to start the water circulation 2 Keep the Ozone Saltwater System turned off 3 Determine the amount of salt to be added see Salt Table 4 Evenly spread the proper amount of salt around the inside perimeter of the pool 5 Avoid clogging the filter Do not add salt through the skimmer 6 Brush the pool bottom to speed...

Page 9: ... 45 25 10 15 x 48 457cm x 122cm 4440 16805 110 50 30 15 16 x 48 488cm x 122cm 5061 19156 125 55 35 15 18 x 48 549cm x 122cm 6423 24311 160 75 40 20 21 x 52 640cm x 132cm 9533 36082 240 110 60 30 24 x 52 732cm x 132cm 12481 47241 310 140 80 35 ULTRA FRAME POOL 16 x 48 488cm x 122cm 5061 19156 125 55 35 15 18 x 48 549cm x 122cm 6423 24311 160 75 40 20 18 x 52 549cm x 132cm 6981 26423 175 80 45 20 20...

Page 10: ... 122cm 7947 30079 2 0 0 9 22 x 52 671cm x 132cm 10472 39637 2 6 1 2 24 x 52 732cm x 132cm 12481 47241 3 1 1 4 26 x 52 792cm x 132cm 14667 55515 3 7 1 7 GRAPHITE GRAY PANEL POOL SET 15 8 x 49 478cm x 124cm 4440 16805 1 1 0 5 16 8 x 49 508cm x 124cm 5061 19156 1 3 0 6 18 8 x 53 569cm x 135cm 6981 26423 1 7 0 8 OVAL FRAME POOL 18 x 10 x 42 549cm x 305cm x 107cm 2885 10920 0 7 0 3 20 x 12 x 48 610cm x...

Page 11: ... 2 2 3 4 16 x 48 488cm x 122cm 5061 19156 2 3 4 6 18 x 48 549cm x 122cm 6423 24311 3 3 4 6 21 x 52 640cm x 132cm 9533 36082 4 5 6 8 24 x 52 732cm x 132cm 12481 47241 5 6 7 8 ULTRA FRAME POOL 16 x 48 488cm x 122cm 5061 19156 2 3 4 6 18 x 48 549cm x 122cm 6423 24311 3 3 4 6 18 x 52 549cm x 132cm 6981 26423 3 4 5 6 20 x 48 610cm x 122cm 7947 30079 4 4 5 6 22 x 52 671cm x 132cm 10472 39637 5 5 6 8 24 ...

Page 12: ...tup Kgs Salt Needed when Low Salt Detected Lbs Salt Needed when Low Salt Detected Kgs Water Capacity Gals x 0 025 Water Capacity Liters x 0 003 Water Capacity Gals x 0 0067 Water Capacity Liters x 0 0008 Water Capacity Operating Time hours at different ambient air temperatures Gals Liters 10 19 C 50 66 F 20 28 C 68 82 F 29 36 C 84 97 F 2000 4000 6000 8000 10000 12000 14000 7500 15000 22500 30000 3...

Page 13: ...will now activate your Ozone Saltwater System at the same time each day for the number of hours you have set NOTE The Ozone Saltwater System will not operate if the filter pump is not operating Make sure to program your filter pump or start it manually for operation beginning 5 minutes before the Ozone Saltwater System and finishing 15 minutes after the Ozone Saltwater System 4 Lock keypad control...

Page 14: ...n the control panel lights up and the LED display flashes 93 The system is now in Stand By mode After a while it shuts down and sets itself in a Power Saving mode The system will automatically turn itself back on in 24 hours starting its daily cycle of sodium hypochlorite production The SLEEP indicator stays on while the system is in the Power Saving mode The LED display however goes blank after 5...

Page 15: ...ning 08 Operating Hours 8 hours remaining 09 Operating Hours 9 hours remaining 10 Operating Hours 10 hours remaining 11 Operating Hours 11 hours remaining 12 Maximum Operating Hours 12 hours remaining 90 Alarm Code Low Pump Flow No Pump Flow 91 Alarm Code Low Salt Level 92 Alarm Code High Salt Level 93 Stand By Mode Operating Process finished BLANK No Power or Power Saving Mode waiting to start ne...

Page 16: ...its position Do not overtighten Electrolytic Cell Cleaning The electrolytic cell has a self cleaning function incorporated into the electronic control s programming In most cases this self cleaning action will keep the cell working at optimum efficiency If the pool water is hard high mineral content the cell may require periodic manual cleaning To maintain maximum performance we recommend that you...

Page 17: ...he flow sensor from the electrolytic cell 9 housing 5 Pour kitchen grade vinegar into the electrolytic cell 9 to immerse the titanium electrodes Soak for 1 hour 6 Open one side of the cell cover 11 drain and properly dispose of the vinegar Connect the hose which goes from the pool to the cell Flush the electrolytic cell housing with the pool water 7 Reverse steps 3 4 5 and 6 to reconnect the elect...

Page 18: ...st the chemical level in the pool water It is very important to use the proper technique when testing the water s chemical level Read and follow the written strip instructions carefully 1 Disconnect the power cord from the electrical outlet 2 After the pool is completely empty disconnect the Ozone Saltwater System from the hoses by reversing the installation instructions 3 Air dry the unit before ...

Page 19: ...ed to the water will have an affect on pH Result if too high Scale formation cloudy water eye skin irritation poor chlorine efficiency Calcium Hardness Refers to the amount of calcium and magnesium dissolved in the water Result if too high Scale will form and will cause the water to become cloudy Stabilizer Stabilizers extend the life of chlorine in swimming pools Cyanuric Acid Do not add pool che...

Page 20: ... turn on Reset the RCD GFCI Contact Intex Service Center PROBLEM CAUSE SOLUTION IMPORTANT If you continue to experience difficulty please contact our Consumer Service Department for assistance See separate Authorized Service Centers sheet This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 th...

Page 21: ...the filter pump manual Check the direction of the inlet and the outlet hose Reverse the hoses if necessary See Set Up Instructions Clean the flow sensor paying special attention to the hinge See Maintenance Plug the flow sensor firmly into the flow sensor receptacle Reset both timers on the filter pump and Ozone Saltwater System Contact Intex Service Center Remove the electrolytic cell for inspect...

Page 22: ... is supervising pool users about potential pool hazards and about the use of protective devices such as locked doors barriers etc Instruct all pool users including children what to do in case of an emergency Always use common sense and good judgement when enjoying any water activity Supervise supervise supervise For additional information on safety please visit The Association of Pool and Spa Prof...

Page 23: ... be repaired or replaced at no charge Any and all disputes regarding the provisions of this Limited Warranty shall be brought before an informal dispute settlement board and unless and until the provisions of these paragraphs are carried forth no civil action may be instituted The methods and procedures of this settlement board shall be subject to the rules and regulations set forth by the Federal...

Reviews: