OPERATION INSTRUCTIONS
IMPORTANT:
To maximize the ozone output of the system, select a daily start time, usually
after 10:00am, when humidity is the lowest.
1. Turn on the filter pump.
2.
Start up the unit:
Plug the power cord into the electrical outlet and test the GFCI/RCD
(circuit breaker). Press
button. Flashing code “00” appears on the
electronic control station’s LED, indicating that the unit is ready to be
programmed.
3. Set operating hours for Ozone & Saltwater system:
With code “00” flashing, press
button to set
the desired operating hours. See the “Operating
Time Table” for the required operating hours
related to each pool size. Pressing
will
increase the time from 01 to 12 hours maximum.
If you have selected too many hours keep
pressing
to repeat the cycle. The built-in timer
will now activate your Ozone & Saltwater System,
at the same time each day, for the number of hours you have set.
NOTE:
The Ozone & Saltwater System will not operate if the filter pump is not operating.
Make sure to program your filter pump (or start it manually) for operation beginning
5 minutes before the Ozone & Saltwater System and finishing 15 minutes after the Ozone
& Saltwater System.
4. Lock keypad controls:
With the desired hour value showing, press
button until you
hear a “beep”. A green “WORKING” indicator on the control
panel will light up within a few seconds to indicate that the
Ozone & Saltwater system has started sodium hypochlorite-ozone
production. Locking the control buttons into this setting prevents
unauthorized changing of the operating cycle.
NOTE:
If you forget to lock the keypad controls, the system will
automatically lock it and start working 1 minute later.
5. Readjust operating time if necessary:
The operating hours can be re-adjusted if necessary.
Press
button until you hear a “beep” to unlock the
keypad and the current programmed time will flash.
Repeat steps 3 to 4.
(1 to 12 hours max per cycle)