background image

106

GS

SAVE THESE INSTRUCTIONS

(106GS)  MODEL 638G FILTER PUMP  ENGLISH  7.5” X 10.3”  PANTONE 295U  06/28/2014

English

Page 5

SETUP

 INSTRUCTIONS

Be sure you have access to water to fill the pool and chemicals for the water. A small coin can be 
used to tighten the hose clamps 

(7)

.

IMPORTANT: This filter pump is shipped with the air release valve (1) open (open the air 
release valve if necessary). DO NOT replace the air release valve until you reach STEP #8. 
Failure to follow these instructions will result in air trapped inside filter housing; the motor 
will run dry, be noisy and malfunction.
1. 

Assemble above-ground-pool first. Carefully follow the pool’s installation instructions.

2. 

Place the filter pump the length of the hose away from the pool wall where the lower black 

 

protruding hose connection is "sticking-out".

3.

  Insert the nozzle union 

(9 & 10)

 into the upper protruding hose connections. Then insert the 

 strainer 

union 

(9 & 11)

 into the lower protruding hose connections. The hoses 

(8)

 fit over the 

 

strainers inserted into the connections.

4.

  There are two hoses to be connected to the filter pump hose connections. With hose clamps 

 

(7)

, fasten one of the hoses 

(8)

 to the lower protruding hose connection (marked "+" on the 

 

pool liner) and to the upper pump connection (marked "+").

5.

  Connect the second hose to the remaining upper protruding hose connection and to the 

 

lower pump connection. Make sure all the hose clamps 

(7)

 are tight.

6.

  In a counter-clockwise motion unscrew the threaded filter housing collar

 (13)

 from the filter    

 

housing. Grasp and remove the threaded cover 

(3)

. Check to see if a cartridge is inside the 

 

housing. If yes, replace the cover, finger tighten the housing collar 

(13)

 back onto the filter 

 housing. 

7.

  Fill the pool to a level of at least 1-2 inches above the top connection. The water will 

 

automatically flow down into the pump.

8.

  When water starts flowing out of the air release valve hole, screw in the air release valve 

 

back into the filter housing cover. Do not over tighten the valve.    

 

NOTE: Venting the system is necessary for air to escape as the filter housing fills with 

 water.
9.

  Connect the filter pump power cord end to the transformer output receptacle and screw in 

 

the cover. Plug the transformer power cord into a properly installed electrical socket.

10.

  Operate the filter pump until the desired water clarity is obtained.

 

 NOTE: 

Never put pool chemicals directly into the filter pump. This may damage the pump  

and void the warranty.

WARNING

Risk of electric shock. Connect transformer only to a grounding type receptacle 
protected by a ground-fault circuit interrupter (GFCI) or residual current device 
(RCD). Contact a qualified electrician if you cannot verify that the receptacle is 
protected by a GFCI/RCD. Use a qualified electrician to install the GFCI/RCD, 
which has a maximum rate of 30mA. Do not use a portable residual current 
device (PRCD).

Summary of Contents for Krystal Clear 638G

Page 1: ...los derechos reservados Alle Rechte vorbehalten Printed in China Imprim en Chine Impreso en China Gedruckt in China Trademarks used in some countries of the world under license from Marques utilis es...

Page 2: ...X 10 3 PANTONE 295U 06 28 2014 English Page 2 TABLE OF CONTENTS Warnings 3 Parts Reference 4 Setup Instructions 5 7 Maintenance 8 9 Pool Care and Chemicals 8 Long Term Storage 9 Troubleshooting Guide...

Page 3: ...verify that the receptacle is protected by a GFCI RCD Use a qualified electrician to install the GFCI RCD which has a maximum rate of 30mA Do not use a portable residual current device PRCD Always unp...

Page 4: ...er and part numbers NOTE Drawings for illustration purpose only Actual product may vary Not to scale 1 2 3 4 5 6 7 8 9 10 11 12 13 REF NO DESCRIPTION QTY SPARE PART NO 1 1 1 1 1 2 4 2 2 1 1 1 1 10460...

Page 5: ...onnection and to the lower pump connection Make sure all the hose clamps 7 are tight 6 In a counter clockwise motion unscrew the threaded filter housing collar 13 from the filter housing Grasp and rem...

Page 6: ...the air release valve remove the plugs allow any air to escape through the valve before tightening the valve again and replace the pool inlet nozzle 10 and strainer grid 11 The pump is now primed with...

Page 7: ...ee holes form a triangle pattern and are 145mm from each other The holes are slotted with a 7mm width The filter pump can be mounted on a cement base or onto a wooden structure to prevent accidental f...

Page 8: ...when filling the pool as well as during the season Consult your local swimming pool supply store for instructions The season s first filling of the pool may have brackish water requiring extra water a...

Page 9: ...a dry place The storage s temperature should be controlled between 32 degrees Fahrenheit 0 degrees Celsius and 104 degrees Fahrenheit 40 degrees Celsius storage location 11 The original packing can be...

Page 10: ...ken There s air trapped in the pump housing and inlet hose TROUBLE CAUSE SOLUTION Filter cord must be plugged into a 3 wire outlet that is protected by a Class A Ground Fault Circuit Interrupter or RC...

Page 11: ...pool liner Pool liner is slippery and or has a bad odor Water turns blue brown or black when first treated with chlorine Water is cloudy or milky Level is lower than on previous day Dirt or sand on p...

Page 12: ...Service Center will determine the validity of the claim IMPLIED WARRANTIES ARE LIMITED TO THE TERMS OF THIS WARRANTY AND IN NO EVENT SHALL INTEX THEIR AUTHORIZED AGENTS OR EMPLOYEES BE LIABLE TO THE B...

Reviews: