IMPORTANT SAFETY RULES

Read, Understand and Follow All Instructions Carefully Before Installing and Using this Product.

READ AND FOLLOW ALL INSTRUCTIONS

WARNING

These product warnings, instructions and safety rules provided with the product 

represent some common risks of water recreation devices and do not cover all 

instances of risk and danger. Please use common sense and good judgement 

when enjoying any water activity.

•  

To reduce the risk of injury, do not permit children to use this product. Always 

   supervise children and those with disabilities.

•  

Children must stay away from this product and electrical cord(s).

•  Children shall not play with the appliance. Cleaning and user maintenance shall not   

   be made by children without supervision.

•  This appliance can be used by children aged from 8 years and above and persons    

   with reduced physical, sensory or mental capabilities or lack of experience and 

   knowledge if they have been given supervision or instruction concerning use of the    

   appliance in a safe way and understand the hazards involved.

•  

Assembly and disassembly by adults only.

•  

Risk of electric shock. Connect transformer only to a grounding type receptacle 

   protected by a ground-fault circuit interrupter (GFCI) or residual current device     

 

   (RCD). Contact a qualified electrician if you cannot verify that the receptacle is 

   protected by a GFCI/RCD. Use a qualified electrician to install the GFCI/RCD, which    

   has a maximum rate of 30mA. Do not use a portable residual current device (PRCD).

•  

Always unplug the transformer from the electrical outlet before removing, cleaning,     

   servicing or making any adjustment to the product.

•  The plug must be accessible after produc   t is installed.

•  Do not bury the electrical cord. Locate the cord where it will not be damaged by lawn   

   mowers, hedge trimmers and other equipment.

•  The supply cord cannot be replaced. If the cord is damaged the appliance or 

   transformer should be scrapped.

•  

To reduce the risk of electric shock, do not use extension cords, timers, plug adaptors   

   or converter plugs to connect unit to electric supply; provide a properly located outlet.

•  

Do not attempt to plug in or unplug this product while standing in water or when your    

   hands are wet.

•  

Keep the transformer more than 3.5m away from the product.

•  Keep the plug of the transformer more than 4.0m away from the product.

•  Position this product away from the pool, so as to prevent children from climbing on it  

   and accessing the pool.

•  

Do not operate this product when the pool is occupied.

•  

This product is for use with storable pools only. Do not use with permanently

   installed pools. A storable pool is constructed so that it may be readily disassembled  

   for storage and reassembled to its original configuration.

•  This product is intended to be used only for the purposes described in the manual!

FAILURE TO FOLLOW THESE WARNINGS MAY RESULT IN PROPERTY DAMAGE, 

ELECTRIC SHOCK, ENTANGLEMENT OR OTHER SERIOUS INJURY OR DEATH.

Summary of Contents for Krystal Clear 638G

Page 1: ...los derechos reservados Alle Rechte vorbehalten Printed in China Imprim en Chine Impreso en China Gedruckt in China Trademarks used in some countries of the world under license from Marques utilis es...

Page 2: ...X 10 3 PANTONE 295U 06 28 2014 English Page 2 TABLE OF CONTENTS Warnings 3 Parts Reference 4 Setup Instructions 5 7 Maintenance 8 9 Pool Care and Chemicals 8 Long Term Storage 9 Troubleshooting Guide...

Page 3: ...verify that the receptacle is protected by a GFCI RCD Use a qualified electrician to install the GFCI RCD which has a maximum rate of 30mA Do not use a portable residual current device PRCD Always unp...

Page 4: ...er and part numbers NOTE Drawings for illustration purpose only Actual product may vary Not to scale 1 2 3 4 5 6 7 8 9 10 11 12 13 REF NO DESCRIPTION QTY SPARE PART NO 1 1 1 1 1 2 4 2 2 1 1 1 1 10460...

Page 5: ...onnection and to the lower pump connection Make sure all the hose clamps 7 are tight 6 In a counter clockwise motion unscrew the threaded filter housing collar 13 from the filter housing Grasp and rem...

Page 6: ...the air release valve remove the plugs allow any air to escape through the valve before tightening the valve again and replace the pool inlet nozzle 10 and strainer grid 11 The pump is now primed with...

Page 7: ...ee holes form a triangle pattern and are 145mm from each other The holes are slotted with a 7mm width The filter pump can be mounted on a cement base or onto a wooden structure to prevent accidental f...

Page 8: ...when filling the pool as well as during the season Consult your local swimming pool supply store for instructions The season s first filling of the pool may have brackish water requiring extra water a...

Page 9: ...a dry place The storage s temperature should be controlled between 32 degrees Fahrenheit 0 degrees Celsius and 104 degrees Fahrenheit 40 degrees Celsius storage location 11 The original packing can be...

Page 10: ...ken There s air trapped in the pump housing and inlet hose TROUBLE CAUSE SOLUTION Filter cord must be plugged into a 3 wire outlet that is protected by a Class A Ground Fault Circuit Interrupter or RC...

Page 11: ...pool liner Pool liner is slippery and or has a bad odor Water turns blue brown or black when first treated with chlorine Water is cloudy or milky Level is lower than on previous day Dirt or sand on p...

Page 12: ...Service Center will determine the validity of the claim IMPLIED WARRANTIES ARE LIMITED TO THE TERMS OF THIS WARRANTY AND IN NO EVENT SHALL INTEX THEIR AUTHORIZED AGENTS OR EMPLOYEES BE LIABLE TO THE B...