1  Introduction and scope of application 

 

Congratulations on purchasing your 

SEPAMAT F

The 

SMT F

 is designed as a separation unit, for use in single-family homes, apartment buildings, offices 

and industry.  

The DVGW certified, fully automatic and ready-to-connect separation unit fulfills the separation of 
drinking water from category 5 liquids according to DIN EN 1717.  

The integrated pump supplies water on-demand from the separation chamber to the users. The water 
level in the separation chamber is controlled by a floating valve. The drinking water supply and 
emergency overflow are connected to the separation chamber.  

The highest consumer connection point can be a maximum of 20 m above the 

SMT F

 
 

2 Safety 

instructions 

 

 

 

 

The live components have to be installed only by a qualified electrician. In case of 
failure of the electronic device, the product has to be repaired by a qualified 
electrician before being operated again. There is a risk of electric shock!  

The outlet circuit used for the device has to be secured through a circuit breaker 
protected (16 A in several countries). If unavailable, an FI switch with maximum 
operating current of 30 mA has to be connected. 

 

 

These installation and operating guidelines  have  to  be  read  carefully  before 
installing the product. The instructions mentioned have to be followed strictly. 
Modifications to the product are not permitted, otherwise the warranty becomes 
void. 

 

The following points have to be strictly observed during the installation and operation:  

 

Check the product before installation for any visible defects. If defects are present, then the 

product must not be installed. Damaged products can be dangerous.  

 

Installations at the mains water pipeline system have to be only performed by a qualified 

installation company.  

 

A floor drain has to be provided near the installation site, which can collect inadvertent water 

discharges (i.e. pump defects, pipe breakages, etc.) and prevent water damage inside the building.  

 

The mason work behind the water-handling unit must be protected from water damage (i.e. with 

water-resistant coating).  

 

Make sure that the existing emergency overflows are connected and adequately sized.  

 

Remove the mains electrical plug if you will be away for more than 24 hours. 

 

Close the mains water line at the inlet of the device if you will be away for more than 24 hours.  

 

All products must be regularly inspected to maintain proper condition. The minimum inspection 

interval is mentioned in the maintenance section.  

 

Electrical devices may be hazardous for children. Therefore children always have to be kept away 

from the product. Do not let children play with the product.  

Summary of Contents for SEPAMAT F 20

Page 1: ...WATER WE RE IN OUR ELEMENT www intewa com SEPAMAT F Installation and user manual...

Page 2: ...nents of the basic controller 8 5 3 Components of the centrifugal pump 10 5 4 Components of the separation chamber 11 6 Installation instructions 12 6 1 Wall mounting 12 6 2 Connection to the mains wa...

Page 3: ...guidelines have to be read carefully before installing the product The instructions mentioned have to be followed strictly Modifications to the product are not permitted otherwise the warranty become...

Page 4: ...o not install any electrical products in flood prone areas The operator is responsible for adherence of the safety and installation guidelines 3 Scope of delivery Separation unit SEPAMAT F Wall mounti...

Page 5: ...rrent 4 A 5 8A Motor capacitor 12 5 F 20 F Max discharge pressure 4 5 bar 5 5 bar Max flow rate 80 l min 110 l min Noise level ca 60 dBA ca 65 dBA Pump start up pressure 1 0 2 2 bar adjustable factory...

Page 6: ...ump SEPAMAT F20 40 2 Pump terminal box with basic controller 3 Vent cock 4 Pressure line shut off valve 3 4 female 5 Pump controller 6 Separation chamber 7 Stopcock for mains water 3 4 female 8 Mains...

Page 7: ...cally fulfils the requirements of the following EU directives EG Directives for machines 89 392 EWG in accordance with 91 368 EWG EG Low voltage directives 73 23 EWG EG Directives for electromagnetic...

Page 8: ...mmended that only experienced professionals use the pressure setting option The pump start up pressure is set to 1 5 bar by default That means the pump switches on when the system pressure falls below...

Page 9: ...e basic controller The basic controller will be found in the terminal box of the pump 1 where all the electrical components of the SEPAMAT F are connected as well as the motor capacitor required for s...

Page 10: ...controller blue Pump controller black N Pump blue L1 Pump brown 12 13 14 15 16 17 18 19 20 21 22 SS PE PU PE LP PE NE br SS brn SS bl KH schw KH gr n KH rt LP bl LP brn free Protective pump controlle...

Page 11: ...pcs 380 CAPACITOR KIT 47 CAPACITOR ZBR 1 ZBR 1 16 16 O RING NOZZLE 1 pc 1 pcs 84 84 PLUG FRONT 1 pc 1 pcs 88 88 SHUTTER 1 pc 1 pcs 490 490 RUBBER SPACER 1 pc 1 pcs 89 89 SPRING SHUTTER 1 pc 1 pcs 370...

Page 12: ...6 should be approx 2 cm below the overflow rim 4 when the floating valve is closed backside of the container The water level can be adjusted by twisting the black floating body 5 The floating valve i...

Page 13: ...s mounted on a wall with the supplied wall bracket The lid and lateral distances indicated should be adhered to when mounting to provide clear maintenance access The SEPAMAT F is wall mounted in such...

Page 14: ...e and stopcock Screw the gland screw into the container connection and carefully tighten with a fixed wench Note The flexible hose must not be overtightened as this may interfere with the internal flo...

Page 15: ...ne set is connected to the pump controller The flexible hose and the shut off valve then connect to the pressure line set and the pressure line 6 5 Connecting the emergency overflow The SEPAMAT F has...

Page 16: ...tering the SEPAMAT F The position of the backwater level determines the type of line a Backwater level above the emergency overflow drainage height of the supplemental supply container Connection of t...

Page 17: ...e the pump primed with water automatically over the mains water tank In this case the pump cannot be manually filled with water 3 Close the pressure line shut off valve 4 Open the air vent hold a buck...

Page 18: ...lecting switch 8 Trouble shooting Malfunction Cause Solution Pump does not start and the red LED is on Pump shuts off after a brief hum and the RESET Replace the capacitor No water in the priming tank...

Page 19: ...Bestellbezeichnung Multistage centrifugal pump SEPAMAT F 20 1 RMF P20 Multistage centrifugal pump SEPAMAT F 40 1 RMF P40 Basic controller 2 RMF BPL Pump controller BRIO 5 RMF PST BRIO Separation cham...

Page 20: ...ls at INTEWA GmbH J licher Stra e 336 52070 Aachen Tel 0049 241 96605 0 Fax 0049 241 96605 10 Email info intewa de Internet www intewa de For customers in other countries For any queries ordering of s...

Reviews: