Doc. Rev. 0
Installation Manual
URL
tel
http://www.intesis.com
[email protected]
+34 938047134
1 / 4
This information is subject to change without notice.
IntesisBox
®
KNX – Mitsubishi Heavy Industries AC
IntesisBox must be installed by accredited electrician or similar technical personnel, following all the safety instructions
given here, and in accordance always with the country legislation for installation of electric equipment.
IntesisBox can not be installed outdoors or exposed to direct solar radiation, water, high relative humidity or dust.
IntesisBox must only be installed in a restricted access location
In wall mount, fix firmly IntesisBox on a not vibrating surface following the instructions below.
Mounting inside a metallic cabinet properly connected to earth is recommended.
Disconnect always power of any wires before manipulating and connecting them to IntesisBox.
Respect always the expected polarity of power and communication cables when connecting them to IntesisBox.
Supply always a correct voltage to power IntesisBox, see details of voltage range admitted by the device in the technical
characteristics below.
This device was designed for installation in an enclosure. To avoid electrostatic discharge to the unit in environments with
static levels above 4 kV precautions should be taken when the device is mounted outside an enclosure. When working in
an enclosure (ex. making adjustments, setting switches, etc.) typical anti-static precautions should be observed before
touching the unit.
Safety Instructions
WARNING
Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your
health and also may damage seriously the IntesisBox and/or any other equipment connected to it.
Use the software LinkBoxEIB to configure IntesisBox, follow the instructions of the user's manual for more
details.
See instructions to download and install the latest version of LinkBoxEIB and
the user's manual at
http://www.intesis.com/down/eib/linkboxeib.html
Configuration and setup
Disconnect the mains power and power of any bus or communication cable before connecting it to
IntesisBox.
Mount IntesisBox following the instructions given below, respecting the safety instructions given above.
Connect the mains power cable to the supply voltage terminal block of IntesisBox.
Circuit-breaker must be used before the mains power cable. Rating 250V-6A
Connect the communication cables to IntesisBox, see details on the user's manual.
Power IntesisBox and the rest of devices connected to it.
Installation instructions