background image

 

           

       

 

 

 

                         
 
                                      

 

 

 

 

IntesisBox

®

 ASCII Server - BACnet/IP client 

 

Doc. Rev.2 

Installation Manual 

 

 

URL 

email 

tel 

 

http://www.intesis.com                                          
[email protected] 
+34 938047134 
 

    2 / 5 

This information is subject to change without notice.

 

 

 
 
 

1.  Separate the fixing clips in the bottom of the box, pushing  them to the outside until hear the "click" which 

indicates that now the clips are in position for wall mount, see in the figure below. 

 

 

 
 
 
 
 
 

 

 
 
 
 
 

 

2.  Use the holes of the clips to fix the box in the wall using screws. Use the template below for the wall holes. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
With the clips of the box in their original position, insert first the box in the upper edge of the DIN rail and later insert 
the box in the down part of the rail using a small screwdriver and following the steps n the figure below. 

 
 
 
 
 
 
 
 
 

Wall mount 

 

Clips in their original position, for DIN rail 
mount 

Clips in position for wall mount 

DIN

 Rail 

Top view of the box 

IntesisBox

® 

www.intesis.com

 

61 mm 

100 mm 

Ø  3 mm 

DIN rail mount 

 

Side view of the box 

Botton view of the box 

Summary of Contents for IBOX-ASCII-KNX

Page 1: ...c discharge to the unit in environments with static levels above 4 kV precautions should be taken when the device is mounted outside an enclosure When working in an enclosure ex making adjustments setting switches etc typical anti static precautions should be observed before touching the unit Safety Instructions WARNING Follow carefully this safety and installation instructions Improper work may l...

Page 2: ...low 2 Use the holes of the clips to fix the box in the wall using screws Use the template below for the wall holes With the clips of the box in their original position insert first the box in the upper edge of the DIN rail and later insert the box in the down part of the rail using a small screwdriver and following the steps n the figure below Wall mount Clips in their original position for DIN ra...

Page 3: ...et CAT5 cable connected to a hub or switch of the LAN of the building If communicating through the LAN of the building contact the network administrator and make sure UDP traffic and the port used 47808 by default are allowed through all the LAN path If only BACnet IP communication is used and the BACnet device is close to the IntesisBox you can use a crossover ethernet CAT5 cable to connect direc...

Page 4: ...Base T RJ45 ASCII port 1 x EIA232 DB9 male connector DTE SELV LED indicators 1 x Power 2 x ASCII port activity Tx Rx 2 x Ethernet port link and activity LNK ACT Console port EIA232 DB9 female connector DCE SELV Configuration Via console port 1 Firmware Allows upgrades via console port Operational temperature 0 C to 70 C Operational humidity 5 to 95 non condensing Protection IP20 IEC60529 RoHS conf...

Page 5: ...com info intesis com 34 938047134 5 5 This information is subject to change without notice Dimensions External dimensions Free space recommended to install the device with spacing enough for external connections 115 mm 130 mm 100 mm Power Ethernet port 107 mm 105 mm 58 mm ASCII EIA232 port Console port ...