6.4  Lamp Intensity Control 

The PTZ-550

A HD

 head uses 2 35-watt halogen lamp modules, one spot and one flood,

 

which are installed on the top of the camera head. To adjust the intensity of the Flood 
Lamp, turn the Main Lamp Intensity knob (Figure 7) clockwise to brighten, and turn 
counter-clockwise to dim. 

To adjust the intensity of the Spot Lamp, turn the Aux. Lamp Intensity knob (Figure 7) 
clockwise to brighten, and turn counter-clockwise to dim. 

FIGURE 7

 

Summary of Contents for Shot PTZ-550A HD

Page 1: ...ystem Operation Service Manual EM19952 To avoid injury read and understand documentation for each system component prior to operation Direct any questions about operation to InterTest at 908 496 8008...

Page 2: ...Support 4 Warranty Information 5 Unpacking Inspection 6 Assembly 7 Operation 8 Care Maintenance 17 Safety 19 Service Records 20 Replacing Camera Module 21 4 page appendix 2013 iShot and Intertest are...

Page 3: ...ions include Pan Tilt and Pan Tilt speed control Camera Controls Options include Auto Focus Auto Shutter Iris Gain Zoom and Focus control Illumination Control To attain a thorough remote visual examin...

Page 4: ...com Refer to page 5 for InterTest s one year limited warranty on parts and materials Be sure to read all warranty information register your product on line at www intertest com and save this manual f...

Page 5: ...ction with the sale of InterTest Inc equipment This warranty shall not apply to any equipment that has been subject to accident negligence alteration abuse unauthorized repair improper storage or othe...

Page 6: ...ches for proper operation If any portion of the system has suffered damage during shipment please notify InterTest at once Retain all packing material for use in the event that the system or system co...

Page 7: ...onnect the PTZ 550A HD Camera Cable s large Mil Spec bayonet style connector to the Camera port M on the back of the control unit The PTZ 550A HD Camera Cable s Mil Spec connector is keyed and must be...

Page 8: ...et E Pan Tilt Speed Control F Pan Tilt Control G Gain Control H Iris Control I Flood Lamp Intensity J Spot Lamp Intensity K Zoom and Focus Control A B C G D H E I J F K L N O P Q L AC Power Inlet and...

Page 9: ...egrees from origin Figure 4 3 DOWN tilts the camera head down to 50 degrees from origin Figure 4 3 RIGHT pans the entire motor and camera head assembly continuously 360 degrees to the right LEFT pans...

Page 10: ...a to Auto Focus push UP on the Auto Focus Auto Exposure rocker switch Figure 5 2 1 2 FIGURE 5 6 3 Automatic Exposure Control It is recommended that the PTZ 550A HD Camera System be operated in Auto Ex...

Page 11: ...flood which are installed on the top of the camera head To adjust the intensity of the Flood Lamp turn the Main Lamp Intensity knob Figure 7 clockwise to brighten and turn counter clockwise to dim To...

Page 12: ...perate this switch Holding down the switch will NOT continuously make adjustments FIGURE 8 6 6 Camera Shutter Control The shutter speed electronically controls exposure time and frame rate of the came...

Page 13: ...se or graininess of the image Some application conditions might require the camera to operate with more or less gain To increase the gain press UP on the Gain Control rocker switch G and to decrease t...

Page 14: ...to decrease Digital Zoom Enable ON OFF Press Focus Near Far joystick K RIGHT or LEFT to toggle Focus Speed 0 7 Press Focus Near Far joystick K RIGHT to increase LEFT to decrease Near Focus Limit 1cm...

Page 15: ...ll Press Focus Near Far joystick K RIGHT or LEFT to toggle Proceed N to Y Focus Near Far joystick K RIGHT to proceed Reset Reset camera to factory settings Please allow 15 seconds Save Save current me...

Page 16: ...joystick K RIGHT or LEFT to toggle Time ON OFF ON OFF Focus Near Far joystick K RIGHT or LEFT to toggle Hours Minutes Seconds Month Day and Year Press Focus Near Far joystick K RIGHT or LEFT to toggle...

Page 17: ...tem clean and free of corrosive materials With the exception of lamp fuse replacements and camera module refer all service to InterTest technicians 7 2 AC Fuse Replacements 1 Turn the power to the sys...

Page 18: ...ng it directly outward 4 Replace the lamp with a new one purchased through InterTest Inc EM142540 for the Flood Lamp EM63004 for the Spot Lamp 5 Inspect the O ring for damage Replace the O ring if the...

Page 19: ...page 5 is void if the PTZ 550A HD is used in a radiated environment The unit cannot be sent to Intertest Inc s facility for repair MovingComponents The PTZ 550A HD Camera Inspection System contains mo...

Page 20: ...REV 1 V 2 5 20 16 20 9 0 Service Records Product PTZ 550A HD Camera System EM Number EM19952 Serial Number Date of Purchase Date Service Performed...

Page 21: ...ound AS568A 041 2 25 EM66699 O Ring Round 1mm x 14mm 1 30 EM66606 O Ring Round AS568A 016 1 31 EM142536 Purge Cap 1 InterTest Inc 303 Route 94 Columbia NJ 07832 Office 908 496 8008 Fax 908 496 8004 se...

Page 22: ...the related mounting components replacement hardware and replacement O rings required to perform the change Reference Figure 1 for item numbers Tools Required Strap wrench 1 Phillips screw driver 3 32...

Page 23: ...moved aside These are not connected to the camera board they loop around through the top to the lamps These wires are routed through two grooves in the Camera Mounting Bar item 10 and need to be seate...

Page 24: ...a Cap item 4 on securely Avoid pinching O ring 14 If use in wet application perform a pressure test Remove Purge Cap Discard old O ring item 23 from the back cap install new O ring using grease 15 Pre...