Locating The Water Heater continued- 

 
Some models are not equipped with a drain valve. For those models, install 
a drain tee in the cold water inlet as close as practical to the water heater. 

 

Water heater corrosion and component failure can be caused by the heating 
and breakdown of airborne chemical vapors.  Examples of some typical 
compounds that are potentially corrosive are: spray can propellants, cleaning 
solvents, refrigerator and air conditioning refrigerants, swimming pool 
chemicals, calcium or sodium chloride, waxes and process chemicals.  
These materials are corrosive at very low concentration levels with little or no 
odor to reveal their presence. 

NOTE: DAMAGE TO THE WATER HEATER 

CAUSED BY EXPOSURE TO CORROSIVE VAPORS IS NOT COVERED 
BY THE WARRANTY.  DO NOT OPERATE THE WATER HEATER IF 
EXPOSURE HAS OR WILL OCCUR.  DO NOT STORE ANY 
POTENTIALLY CORROSIVE COMPOUNDS IN THE VICINITY OF THE 
WATER HEATER. 
 

This water heater must be located in an area where leakage of the tank or 
water line connections and the combination temperature and pressure relief 
valve will not result in damage to the area adjacent to the water heater or to 
lower floors of the structure.  When such locations cannot be avoided, a 
suitable drain pan must be installed under the water heater.  The drain pan 
must have a minimum length and width of at least 4 in. (10.2 cm) greater 
than the diameter of the water heater. The drain pan, as described above, 
can be purchased from your plumbing professional.  The drain pan must be 
piped to an adequate drain.  The piping must be pitched for proper drainage. 

 

This water heater MUST be installed indoors out of the wind and 
weather.

 

 
To comply with NSF requirements this water heater is to be: 

a)  Sealed to the floor with sealant, in a smooth and easily cleanable 

way, or 

b)  Installed with an optional leg kit that includes legs and/or extensions 

that provide a minimum clearance of 6” beneath the water heater. 

 

Note: For California installation this water heater must be braced, 
anchored, or strapped to avoid falling or moving during an earthquake.  
See instructions for correct installation procedures.  Instructions may 
be obtained from the DSA Headquarters Office, 1102 Q Street, Suite 
5100, Sacramento, CA 95811.

 

Summary of Contents for TWO GALLON ELECTRIC WATER HEATER

Page 1: ...WITH THESE INSTRUCTIONS READ THESE INSTRUCTIONS THOROUGHLY BEFORE STARTING For your family s comfort safety and convenience we recommend this water heater be installed and serviced by a plumbing prof...

Page 2: ...enclosed warranty and refer to it when questions arise If you have any specific questions concerning your warranty please consult the plumbing professional from whom your water heater was purchased F...

Page 3: ...or the purpose of heating potable water The installation and use of this water heater for any purpose other than the heating of potable water may cause damage to the water heater and create a hazardou...

Page 4: ...these instructions After reading these installation and operating instructions select a location for the water heater where the floor is level and is easily accessible to a power supply and water conn...

Page 5: ...and the combination temperature and pressure relief valve will not result in damage to the area adjacent to the water heater or to lower floors of the structure When such locations cannot be avoided a...

Page 6: ...xpansion DO NOT operate this water heater in a closed system without provisions for controlling thermal expansion Your water supplier or local plumbing inspector should be contacted on how to control...

Page 7: ...the opening provided and marked for this purpose on the water heater Note Some models may already be equipped or supplied with a combination temperature and pressure relief valve Verify that the comb...

Page 8: ...e available from your local plumbing supplier Please consult with a plumbing professional APPROXIMATE TIME TEMPERATURE RELATIONSHIPS IN SCALDS 120 F 49 C More than 5 minutes 125 F 52 C 1 to 2 minutes...

Page 9: ...free type and has been factory installed to interrupt all ungrounded power supply conductors in the event of thermostat failure Thermostats are factory set and wired in accordance with the wiring diag...

Page 10: ...liances require high temperature hot water such as dishwashers and automatic clothes washers TO FILL THE WATER HEATER 1 Open the cold water supply shut off valve 2 Open several hot water faucets to al...

Page 11: ...plastic terminal shield has not been displaced replace the access panel The water heater is now ready for operation and the main switch can be closed Figure 1 MAINTENANCE CAUTION Before adjusting the...

Page 12: ...the power supply to the water heater and contact the plumbing professional that installed this water heater or a qualified service technician 3 At least once a year check the combination temperature...

Page 13: ...e time interval for inspection and replacement of the anode rod Contact the plumbing professional who installed the water heater or the manufacturer listed on the rating plate for anode replacement in...

Page 14: ..._____ Supplier ______________________________________________________ Supplier Phone No ______________________________________________ Manufactured under one or more of the following U S Patents RE 34...

Page 15: ...15 NOTES...

Page 16: ...16 NOTES...

Reviews: