20
START UP INSTRUCTIONS
1.
Make sure service switch to boiler is off.
2.
Make sure boiler has been filled with water until entire system has been purged
and desired pressure is obtained.
3.
Check all fittings for leaks.
4.
The PB150 boiler is supplied with a plug in the metering cup. If burning wood
pellet only, this plug can be removed to increase firing rate.
5.
Add fuel to the hopper. If burning corn add oyster shell to the pot.
6.
Set shutter on draft fan at 50% (1/2 way open).
7.
On the aqua stat set the high limit control on the left side at 200
°
F., low limit
control on the right side at 160
°
F. and the differential setting at 130
°
F. This is
the factory-preset level.
8.
Set primary control (OII350S) cycle time switch at 8 minutes and pilot draft
switch at Medium. Turn on service switch.
9.
Place two (4) cups of pellets in the bottom of the fire pot. Apply a non-volatile
lighting material on top of pellets and light with a match.
WARNING
DO NOT USE CHEMICALS OR FLUIDS TO START THE FIRE.
DO NOT BURN GARBAGE, GASOLINE, NAPHTHA, ENGINE OIL OR OTHER
INAPPROPRIATE MATERIALS.
10.Close door and let fire establish. Set on/off switch on primary control to Feed
System
11.Combustion fan should come on to high speed. The fire in the pot will increase.
When the safety disc on the smoke collector box reaches 49°C (120°F)
temperature, it will close, and then the cup and auger motor will start adding
more fuel to the fire pot. The unit will run until it reaches 160°F at which time
the burner will cycle into pilot mode and the circulation pump will come on to
supply hot water throughout the system.
Summary of Contents for Pinnacle PB150
Page 4: ...3 SPECIFICATIONS Figure 1...
Page 14: ...13 Figure 3...
Page 16: ...15 Figure 5...
Page 17: ...16 Figure 6...
Page 30: ...29 NOTES...