www.intertec.info
Operating Instructions Temperature Controller TC D
HOM107626379Ien-7
Page 5 / 6
INTERTEC-Hess GmbH · Raffineriestr. 8 · 93333 Neustadt/Donau · Germany ·
+49 9445 9532-0 · [email protected]
1
2
3
4
5
6
7
8
9
10
11
12
13
L
N
PE
NTC
RS 485
F1
TC DIGITAL
CP...THERM...HI
external sensor
br=brown bl=blue ye/gn=yellow/green bk=black gr=grey
bl br gn/ye
gr bk
+
A
B
Ground
Illustration 2:
Temperature controller TC digital circuit diagram
8
Test software and setup software
If you have ordered the "SMART HEATER software" as
well, then please read the "TC SMART Modbus
Software" operating instructions for individually setting
the parameters and recording the data.
9
Maintenance
The design of the device does not require any
maintenance.
Functional and safety test intervals can be freely
selected by the operator in accordance with the
applicable regulations.
Repairs may only be carried out by the manufacturer in
the factory.
All components have to be kept clean and free of dust
and harmful substances that could lead to excessive
temperature rise.
In the dust Ex area, the applicable requirements of EN
60079-17 and EN 60079-19 must be complied with.
10
Troubleshooting
In the case of failure of the temperature controller or
performance fluctuations, please check the operating
conditions. See also:
.
If the device is defective, it must be removed and sent
back to the manufacturer for repair.
11
Deinstallation
Disassembly may only be carried out by a trained
person.
DANGER
Risk of fatal injury from electric current!
If contact is made with live components, there is the risk
of fatal injury.
For this reason, switch off the voltage supply, secure
against being switched on again and check that no more
voltage is present.
Disconnect connection line from the clamps and from the
connection socket, disconnect device from bracket and
remove it.
12
Disposal
Disassemble the components of the product, taking the
applicable local labour protection and environmental
regulations into consideration and make sure that the
components are recycled:
• Scrap metal
• Send plastic elements to recycling
• Sort other components according to their material
properties and dispose of them.
NOTICE
Environmental damage may be caused if
disposed of incorrectly!
Electrical scrap and electronics components are subject
to hazardous waste treatment and must only be
disposed of by certified specialists!
The local community authorities or specialist waste
disposal companies can provide information on
environmentally friendly disposal.
13
EU declaration of conformity