background image

www.intertec.info

Operating Instructions SL VARITHERM DPA

Page 8 / 8

HOM500327947Ien-7

INTERTEC-Hess GmbH · Raffineriestr. 8 · 93333 Neustadt/Donau · Germany · 

 +49 9445 9532-0 ·   [email protected]

NOTICE

Environmental damage may be caused if
disposed of incorrectly!

Electrical scrap and electronics components are subject
to hazardous waste treatment and must only be
disposed of by certified specialists!

The  local  community  authorities  or  specialist  waste
disposal  companies  can  provide  information  on
environmentally friendly disposal.

14

EU declaration of conformity

The 

manufacturer, 

INTERTEC-Hess 

GmbH,

Raffineriestrasse  8,  93333  Neustadt/Donau,  Germany,
hereby declares in sole responsibility that the product

Product / Type designation:

SL VARITHERM

complies  with  the  provisions  of  the  following  directives
2014/34/EU  (ATEX),  2014/30/EU  (EMC),  2011/65/EU
(RoHS), 2012/19/EU (WEEE) complies with the following
standards,  harmonized  standards,  where  appropriate
and/or standardized documents:

EN IEC 60529:1991+A1:2000+A2:2013

EN IEC 60079-0:2018

EN IEC 60079-1:2014

EN IEC 60079-31:2014

EN IEC 61000-6-4:2007+A1:2011

Harmonized Standard (RoHS):

DIN EN IEC 63000:2019

Designation:

0102

II 2 G Ex db IIC T6, T5, T4, T3 Gb

II 2 D Ex tb IIIC T85°C, T100°C, T135°C, T200°C Db

PTB 02 ATEX 1116 X

Neustadt, January 28th, 2020

Dipl.-Ing. Martin Hess, Managing Director

15

Further information and service

If  the  information  contained  in  this  instruction  manual
should  not  be  sufficient  in  any  way,  then  INTERTEC
would  be  glad  to  be  at  your  disposal  to  provide  further
information and service.

Please  contact  your  INTERTEC  contact  person  or
directly contact

INTERTEC-Hess GmbH

Raffineriestr. 8

93333 Neustadt/Donau

Germany

Phone: +49 9445 9532-0

e-mail: [email protected]

Website: www.intertec.info

Warranty

The  legally  defined  warranties  and  warranty  periods  of
24  months  are  applicable  to  our  scope  of  supply  and
services.

You  will  find  more  detailed  information  in  the
manufacturer  warranty  from  INTERTEC  for  heating
systems and accessories.

These instructions do not claim to take all

designs, options or changes into

consideration, even in association with

installation, operation or maintenance.

INTERTEC does not accept responsibility

for providing information about changes

made retrospectively.

Summary of Contents for SL VARITHERM DPA

Page 1: ...Operating Instructions SL VARITHERM DPA HOM500327947Ien 7 17 12 2020 ...

Page 2: ...f contents 1 General 3 2 Use 3 3 Explanation of symbols for warnings and signal words 3 4 Safety information 3 5 Installation accessories 4 6 Technical Data 4 7 Installation 4 8 Connection 5 9 Commissioning 7 10 Maintenance 7 11 Troubleshooting 7 12 Deinstallation 7 13 Disposal 7 14 EU declaration of conformity 8 15 Further information and service 8 ...

Page 3: ...connecting cable If a TAE is used the respective operating instructions must be complied with EC type examination certificates PTB 02 ATEX 1116 X with appendices and supplements in German and English as well as IEC Scheme Certificate IECEX PTB 07 0055X See http www intertec info 3 Explanation of symbols for warnings and signal words The safety information warns the user about risks and provide inf...

Page 4: ...V AC Rated current in compliance with VDE 0298 max 10 A Ambient temperature 60 to 60 C Max permitted operating temperature 60 to 180 C Switching capacity of fault alarm AM 10 A 275 V AC Connecting cable Silicone hose cable notch and oil resistant 3 x 1 5 mm Connecting cable AM Silicone hose cable notch and oil resistant 5 x 1 0 mm Ø8 5 mm Material Seawater proof aluminium black anodized Mean Time ...

Page 5: ...earance Illustration 3 Installation example vertical VARITHERM with TAE or TS with clearance Additional installation material such as rails or panels and also junction boxes are not included in the standard scope of delivery see Installation accessories Page 4 and must be ordered additionally 8 Connection INFO The device may only be connected up and secured by a trained person taking into account ...

Page 6: ...efer also to DIN EN 60079 14 section 7 4 ATTENTION Never remove the adapter cable gland Illustration 4 Example heater with KLE connection CAUTION NOTICE Do not remove adapter cable connection to connect up the heater This would cause irreversible damage to the heater and this would mean that the explosion protection can no longer be warranted The illustration may deviate from the heater 1 2 L N PE...

Page 7: ...ied out by the manufacturer in the factory All components have to be kept clean and free of dust and harmful substances that could lead to excessive temperature rise In the dust Ex area the applicable requirements of EN 60079 17 and EN 60079 19 must be complied with 11 Troubleshooting If the heater fails check the installation Carry out a continuity test on the heating circuit Pay attention to the...

Page 8: ...N IEC 60079 1 2014 EN IEC 60079 31 2014 EN IEC 61000 6 4 2007 A1 2011 Harmonized Standard RoHS DIN EN IEC 63000 2019 Designation 0102 II 2 G Ex db IIC T6 T5 T4 T3 Gb II 2 D Ex tb IIIC T85 C T100 C T135 C T200 C Db PTB 02 ATEX 1116 X Neustadt January 28th 2020 Dipl Ing Martin Hess Managing Director 15 Further information and service If the information contained in this instruction manual should not...

Reviews: