Operating Instructions SL VARITHERM DPA

HOM500327947Ien-7

Page 7 / 8

INTERTEC-Hess GmbH · Raffineriestr. 8 · 93333 Neustadt/Donau · Germany · 

 +49 9445 9532-0 ·   [email protected]

1

2

J

L
N
PE

J

Junction box

Heater

TS

Option AM

bn

bu

ye/gn

bk

gy

bn=brown bu=blue ye/gn=yellow/green bk=black gy=grey

Illustration 6: 

SL...THERM with TS

9

Commissioning

If the heater is installed in accordance with the notes in
the 

Installation  [

}

Page  4]

  section  and 

Connection  [

}

Page  5]

 

sections, 

then 

the 

radiator 

may 

be

commissioned.

 CAUTION

Sufficient heat dissipation must be ensured.

Unauthorized covers must be removed as otherwise
there is the risk of the heater overheating.

The heating circuit is permanently disconnected by a
temperature melt fuse which can't be reset if these
installation instructions are not adhered to.

10

Maintenance

The  design  of  the  device  does  not  require  any
maintenance.

Functional  and  safety  test  intervals  can  be  freely
selected  by  the  operator  in  accordance  with  the
applicable regulations.

Repairs  may  only  be  carried  out  by  the  manufacturer  in
the factory.

All  components  have  to  be  kept  clean  and  free  of  dust
and  harmful  substances  that  could  lead  to  excessive
temperature rise.

In  the  dust  Ex  area,  the  applicable  requirements  of  EN
60079-17 and EN 60079-19 must be complied with.

11

Troubleshooting

If  the  heater  fails,  check  the  installation.  Carry  out  a
continuity test on the heating circuit. Pay attention to the
connection  diagram  and  switching  point  of  the
thermostat!

12

Deinstallation

Disassembly  may  only  be  carried  out  by  a  trained
person.

 DANGER

Risk of fatal injury from electric current!

If contact is made with live components, there is the risk
of fatal injury.

For this reason, switch off the voltage supply, secure
against being switched on again and check that no more
voltage is present.

Disconnect connection line from the clamps and from the
connection  socket,  disconnect  device  from  bracket  and
remove it.

13

Disposal

Disassemble  the  components  of  the  product,  taking  the
applicable  local  labour  protection  and  environmental
regulations  into  consideration  and  make  sure  that  the
components are recycled:

• Scrap metal

• Send plastic elements to recycling

• Sort other components according to their material

properties and dispose of them.

Summary of Contents for SL VARITHERM DPA

Page 1: ...Operating Instructions SL VARITHERM DPA HOM500327947Ien 7 17 12 2020 ...

Page 2: ...f contents 1 General 3 2 Use 3 3 Explanation of symbols for warnings and signal words 3 4 Safety information 3 5 Installation accessories 4 6 Technical Data 4 7 Installation 4 8 Connection 5 9 Commissioning 7 10 Maintenance 7 11 Troubleshooting 7 12 Deinstallation 7 13 Disposal 7 14 EU declaration of conformity 8 15 Further information and service 8 ...

Page 3: ...connecting cable If a TAE is used the respective operating instructions must be complied with EC type examination certificates PTB 02 ATEX 1116 X with appendices and supplements in German and English as well as IEC Scheme Certificate IECEX PTB 07 0055X See http www intertec info 3 Explanation of symbols for warnings and signal words The safety information warns the user about risks and provide inf...

Page 4: ...V AC Rated current in compliance with VDE 0298 max 10 A Ambient temperature 60 to 60 C Max permitted operating temperature 60 to 180 C Switching capacity of fault alarm AM 10 A 275 V AC Connecting cable Silicone hose cable notch and oil resistant 3 x 1 5 mm Connecting cable AM Silicone hose cable notch and oil resistant 5 x 1 0 mm Ø8 5 mm Material Seawater proof aluminium black anodized Mean Time ...

Page 5: ...earance Illustration 3 Installation example vertical VARITHERM with TAE or TS with clearance Additional installation material such as rails or panels and also junction boxes are not included in the standard scope of delivery see Installation accessories Page 4 and must be ordered additionally 8 Connection INFO The device may only be connected up and secured by a trained person taking into account ...

Page 6: ...efer also to DIN EN 60079 14 section 7 4 ATTENTION Never remove the adapter cable gland Illustration 4 Example heater with KLE connection CAUTION NOTICE Do not remove adapter cable connection to connect up the heater This would cause irreversible damage to the heater and this would mean that the explosion protection can no longer be warranted The illustration may deviate from the heater 1 2 L N PE...

Page 7: ...ied out by the manufacturer in the factory All components have to be kept clean and free of dust and harmful substances that could lead to excessive temperature rise In the dust Ex area the applicable requirements of EN 60079 17 and EN 60079 19 must be complied with 11 Troubleshooting If the heater fails check the installation Carry out a continuity test on the heating circuit Pay attention to the...

Page 8: ...N IEC 60079 1 2014 EN IEC 60079 31 2014 EN IEC 61000 6 4 2007 A1 2011 Harmonized Standard RoHS DIN EN IEC 63000 2019 Designation 0102 II 2 G Ex db IIC T6 T5 T4 T3 Gb II 2 D Ex tb IIIC T85 C T100 C T135 C T200 C Db PTB 02 ATEX 1116 X Neustadt January 28th 2020 Dipl Ing Martin Hess Managing Director 15 Further information and service If the information contained in this instruction manual should not...

Reviews: