 DANGER

Risk of fatal injury from electric current!

If contact is made with live components, there is the risk
of fatal injury.

For this reason, switch off the voltage supply, secure
against being switched on again and check that no more
voltage is present.

 INFO

Repairs may only be carried out by the manufacturer
(INTERTEC-Hess) in all cases.

Do not disassemble the device! Opening the units will
render the warranty invalid.

Fault:

Remedial action:

Connection

Connection line not

connected properly

Check connection

Mains voltage has a

different frequency than

230-250 V AC 50 Hz

Check mains voltage and

frequency

Fan used for cooling:

Power supply is

interrupted by external

thermostat

Room air is cooler than the

temperature set on the

thermostat

Connecting cable is

damaged

The connecting cable must be

protected mechanically

Fan blade

Foreign bodies in the fan

blade

Remove foreign bodies –

make sure that the fan can

move freely

Blocked fan blade

overheats the motor –

thermal safety fuse is

triggered

Device must be replaced

Auxiliary fan blocked

Use spacers to create space

Temperature

Temperature of suction

medium is greater than
+60°C – thermal safety

fuse is triggered

The temperature of the

pumped medium must always

be less than +60°C

Device must be replaced

Fault alarm is triggered

Cause: Motor blocked

Device must be replaced

9

Maintenance

The  filter  must  be  changed  at  regular  intervals
depending  on  the  degree  of  contamination  of  the  intake
air.

NOTICE

Only change the filter from the outside through the
filter cover!

Illustration 5: 

Open the filter with the aid of the top slat

Illustration 6: 

Replace filter mat – make sure that the filter is

positioned correctly

Only  the  original  spare  parts  must  be  used,  since
otherwise  the  warranty  and  approval  will  be  rendered
invalid.  Furthermore,  if  the  original  spare  parts  are  not
used,  protection  classes  and  performance  data  can  no
longer be guaranteed.

10

Directions for use

To  preserve  the  operational  capability  and  to  prevent
unplanned downtimes of the device, please observe the
following measures:

Bearing/drive shaft: 

Both must be kept free of contamination, visual
inspection at 3-month intervals, or at even shorter
intervals if necessary

Filter mat: 

When used as a filter fan, carry out regular
inspections for contamination, replace if necessary

Corrosion: 

Highly aggressive media must be avoided

Summary of Contents for FL-ExVENT

Page 1: ...Operating Instructions Filter ventilator FL ExVENT COM155769227Ien 4 24 08 2021...

Page 2: ...o Table of contents 1 Use 3 2 Explanation of symbols for warnings and signal words 3 3 Safety information 3 4 Technical Data 3 5 Installation 4 6 Connection 5 7 Commissioning 5 8 Troubleshooting 5 9 M...

Page 3: ...must be adhered to are highlighted as follows DANGER DANGER This sign is warning about an extremely hazardous situation which if not heeded will lead to death or serious irreversible injury WARNING W...

Page 4: ...2 x 252 44 Smooth the edges of the mounting cut out The FL ExVENT is inserted from the outside through the opening The clamping lugs can be perceptibly and audibly clicked into place in all four corne...

Page 5: ...ent The fuse must be housed in the associated power supply unit or separately upstream The fuse rated current must be the same as or greater than the specified maximum working voltage of the electric...

Page 6: ...ty fuse is triggered Device must be replaced Auxiliary fan blocked Use spacers to create space Temperature Temperature of suction medium is greater than 60 C thermal safety fuse is triggered The tempe...

Page 7: ...OTICE Environmental damage may be caused if disposed of incorrectly Electrical scrap and electronics components are subject to hazardous waste treatment and must only be disposed of by certified speci...

Page 8: ...e legally defined warranties and warranty periods of 24 months are applicable to our scope of supply and services You will find more detailed information in the manufacturer warranty from INTERTEC for...

Reviews: