Installer’s Guide

MODES OF OPERATION

The whole house air cleaner can be connected in one 

of two modes of operation; either a 24 V mode or a 

communicating mode.  To know how the whole house 

air cleaner is set up, reference Figure 21 to find the 

amber light.
A steady amber light indicates that the unit is wired in 

the 24 V mode. 

A blinking amber light indicates that the unit is wired in 

the communicating mode. 

No light present means that the unit is not connected.

Figure 21 - Amber Light showing 

Mode of Operation

BLUE

GREEN

BROWN

BLACK

RED

WHITE

Air Handler may not have a Low Voltage Terminal board.  Connect Electronic Air Cleaner wires to 
the Air Handler Low Voltage Color coded wires.
Install Transformer, one is supplied with the Electronic Air Cleaner, in the Furnace or Air Handler.

Figure 20A - Wiring Diagram 

for 24 V Mode

NOTE:  The Black wire must be con

-

nected to chassis ground to  ensure 

proper operation.

The 

 represents an alpha character.

BAYTRANS12024

◆ 

 Transformer 

BLUE

GREEN

Furnace / Air Handler

BROWN /

Dataline

Indoor Unit       

24 V Terminal Strip

WHITE

RED

BLUE

GREEN

WHITE

24 V

Common

Fan Signal

Furnace

Heating Signal

R

B

W

G

BLUE

GREEN

BROWN

BLACK

RED

WHITE

•  Transformer must have a grounded 120 VAC 

power source.  Do not defeat ground plug on 

the transformer. 

 

•  Mount transformer to building structure with 

the four provided wood screws.

Transformer not applicable to 50 Hz units.

NOTE:  BAYTRANS12024C 

complies with the 

Cali

-

fornia Code of Regulation,Title 20, Sections 1601 

through 1608

 dated December 2006. 

  BAYTRAN

-

S12024A 

with vendor’s manufacturing date codes 

after 0625 (YYWW) 

cannot be installed

 in California 

because the transformer does not satisfy the require-

ments set forth by 

California Code of Regulations, 

Title 20, Sections 1601 through 1608

 dated Decem-

ber 2006.  

Power Button

Amber Light

Plug 24 Volt Power / Control 
Cable in here.

Summary of Contents for EFD145DLFR000 Series

Page 1: ...t comply with NATIONAL STATE AND LOCAL CODES IMPORTANT This Document is customer property and is to remain with this unit Please return to service information pack upon completion of work Installation...

Page 2: ...heck carefully for any shipping damage This must be reported to and claims made against the trans portation company immediately Check to be sure all major components are in the unit Any missing parts...

Page 3: ...air cleaner to air handler furnace or ductwork please keep screws out of the circled areas The door attaches to the slots in the location Figure 7 Avoiding Screw Interference Supply Plenum Furnace or...

Page 4: ...ions are preferred for greatest efficiency Four inches per linear foot approximately 20 angle should be allowed space permitting 9 Seal all joints in the return air system to prevent dust from enterin...

Page 5: ...R FIELD CHARGER and both COLLECTION CELLS Set the components aside until the cabinet is installed and the indoor unit is in place 2 Install the self adhesive gasket material on the side of the air cle...

Page 6: ...n the side of the air cleaner cabinet flange that will mate with the indoor unit This flange has a double set of holes See Figure 14 UPFLOW AIR HANDLER APPLICATIONS ONLY 9 Position the baffle onto the...

Page 7: ...the indoor unit is in place 2 Install the self adhesive gasket material on the side of the air cleaner cabinet flange that will mate with the indoor unit This flange has a double set of holes See Fig...

Page 8: ...E Wiring penetration must be sealed NOTE For non Trane American Standard Heating Air Conditioning systems order a 120 VAC to 24 VAC transformer KIT BAYTRANS12024 to provide 24 volt power only to the a...

Page 9: ...ndler Figure 20A Wiring Diagram for 24 V Mode NOTE The Black wire must be con nected to chassis ground to ensure proper operation The represents an alpha character BAYTRANS12024 Transformer BLUE GREEN...

Page 10: ...power going into the air handler 2 On the communicating systems air handler remove the blower access panel 3 Remove the communicating control box cover 4 Locate the red jumper wire which is attached f...

Page 11: ...ISCONNECT POWER BEFORE SERVICING COULD RESULT IN DEATH OR SERIOUS INJURY ELECTRICAL CONNECTIONS TO A STANDARD 24 VOLT AIR HANDLER Field wiring O R B YI W1 YO Y2 BK G W2 W3 In Out O R B YI W1 YO G W2 W...

Page 12: ...wire from the air cleaner wire harness to earth ground by attaching the wire to a grounded screw that is connected to the metal air handler chassis or control plate assembly 7 The Green and White wir...

Page 13: ...quick connect terminal to the blue wire and the green wire 9 Attach the blue wire from the air cleaner wiring harness to the open tab on the piggyback terminal supplied in the BAYACCECOMM101 Attach pi...

Page 14: ...with the air cleaner onto the IFC platform where the 35VA transformer was previously located Use the sheet metal screws supplied with the air cleaner to mount the 50VA transformer Reconnect the 115V...

Page 15: ...and RH together Oil burner primary TT contacts must be isolated using field supplied relay RLY00925 or equivalent NOTE 3 The black wire Bk from ACCE unit must be connected to chassis ground to ensure...

Page 16: ...e the wiring diagrams for information on how to attach the wires in a two whole house air cleaner system The figure on the top of page 16 shows the wiring hookup for two whole house air cleaners attac...

Page 17: ...ems 17 Installer s Guide FIELD SUPPLIED 50 VA TRANSFORMER FIELD SUPPLIED 75 VA TRANSFORMER ELECTRICAL CONNECTIONS FOR DUAL WHOLE HOUSE AIR CLEANERS AND FURNACE IN CONVENTIONAL 24V MODE ELECTRICAL CONN...

Page 18: ...IELD CHARGER in the SET UP mode NOTE There is a 10 12 minute delay after the indoor fan operates before the air cleaner starts to operate each time the power to the air cleaner is turned off on This c...

Page 19: ...ER is to capture large particles before they enter the COLLECTION CELLS which allows the collection cells to work more efficiently 1 Turn the air conditioning system off at the Comfort Control thermos...

Page 20: ...a vacuum hose vacuum in even strokes across the length of the PRE FILTER After vacuuming the entire PRE FILTER using even strokes going in one direction repeat the process using even strokes going in...

Page 21: ...R CLEANER 1 Replace the PRE FILTER into the air cleaner Ensure that the AIRFLOW indicator arrow on the PREFILTER is pointing in the same direction as the AIRFLOW indicator arrow on the air cleaner cab...

Page 22: ...ell Identification Alternate Cleaning option for homeowners with 200 or 200 1 COLLECTION CELLS ONLY Vacuuming the PRE FILTER and COLLECTION CELLS restores them to a high efficiency However some enviro...

Page 23: ...and hold the RESET key until the COLLECTION CELL LED turns off 1 to 2 seconds If two air cleaners are connected on the same system reset all timers on both air cleaners at the same time to the same se...

Page 24: ...de View AIRFLOW 27 DEPTH CABINET ADD DOOR DEPTH FOR TOTAL OUTLINE DRAWING FOR UPFLOW FURNACES Dimensions all dimensions in inches I OUTLINE DRAWINGS UPFLOW FURNACE MODEL NUMBERS ifD Air Cleaner A B mu...

Page 25: ...D DOOR DEPTH FOR TOTAL Dimensions all dimensions in inches OUTLINE DRAWING FOR DOWNFLOW FURNACES DOWNFLOW FURNACE MODEL NUMBERS ifD Air Cleaner A B multiple piece cabinet B one piece cabinet EFD17DCLF...

Page 26: ...EPTH CABINET ADD DOOR DEPTH FOR TOTAL OUTLINE DRAWING FOR AIR HANDLERS AIR HANDLER MODEL NUMBERS ifD Air Cleaner A B multiple piece cabinet B one piece cabinet EFD175CLAH000E 17 5 14 9 15 EFD215CLAH00...

Page 27: ...FD175DLFR000 0 05 0 08 0 12 0 17 0 22 0 28 0 34 EFD210DLFR000 0 04 0 06 0 09 0 12 0 15 0 20 0 24 0 29 0 34 EFD245DLFR000 0 03 0 04 0 06 0 09 0 12 0 15 0 19 0 22 0 26 EFD17DDLFR000 0 07 0 11 0 18 0 25...

Page 28: ...idential applications For more information please visit www trane com or www americanstandardair com The manufacturer has a policy of continuous data improvement and it reserves the right to change de...

Reviews: