C. DOOR OPERATION

 

The air cleaner comes with the Power Door installed on 

the unit.  The Power Door and the internal components 

will need to be removed before installation.  Follow 

these guidelines for removing and reinstalling the door:

REMOVING THE POWER DOOR:

Step 1:

 Remove the Door Assembly from Whole Home 

Air Cleaner by pulling away from the unit assembly.  

Place on the flat and clean working surface with interior 

components facing up. See Figure 10.

Figure 9  Turning Vanes

4.   Install the air cleaner such that the airflow direc

-

tion arrow on the cabinet always points towards the 

furnace/ air handler. See Figure 8.

5.   The PRE-FILTER must be on the entering airstream 

side of the air cleaner cabinet. The mounting flange 

on this side of the cabinet has the single row of 

holes for attaching ductwork. 

6.   On side return furnace applications, the air cleaner 

may be installed on either side of the cabinet or both 

sides of the furnace if two air cleaners are required 

to reduce system static.

    Position the PRE-FILTER on the side away from 

the furnace. The COLLECTION CELL guide key, 

installed in the cabinet will only allow the cells to 

be installed in the proper direction. Airflow direction 

must agree with airflow arrows on the cabinet.

7.   It is recommended that sheet metal turning vanes 

be installed inside an elbow on ductwork attached 

to the entering airstream side of the air cleaner. This 

improves the air distribution over the COLLECTION 

CELLS. See Figure 9.

8.   Use transition fittings where return air duct dimen

-

sions do not match the air cleaners opening dimen-

sions. Gradual transitions are preferred for greatest 

efficiency. Four inches per linear foot (approximately 

20°

 angle) should be allowed, space permitting.

9.   Seal all joints in the return air system to prevent 

dust from entering the air stream.

NOTE:  Do NOT use a silicon based sealant. This 

causes a coating on the FIELD CHARGER pins that 

ill decrease the efficiency of the air cleaner.

Figure 8  Airflow Direction

Airflow 

Direction 

Arrow

Select a location that meets the following:

1.   The face of the cell must be at a right angle to the 

air stream.

2.   Allow a minimum of 28 inches clearance in front 

of the air cleaner to permit removal of cells and 

Pre-Filter.

3.  

Flow-through Bypass Humidifiers

 

Excessive bypass air may cause water blow-off, 

which will adversely affect system operation and air 

cleaner performance. To verify bypass airflow, follow 

the Bypass Humidifier Pre-Installation Checkout and 

Set-Up Procedures available through your local dis-

tributor. Ask for publication number 18-CH37D1-*. 

 

Steam and Flow-through Fan Power Duct-mounted 

Humidifiers

 

Follow the Humidifier installation instructions. These 

should only be installed on the supply air side of the 

system. 

 

Other Duct Mounted Humidifiers

 

Not recommended for installation with the air cleaner.

Hazardous Voltage!

Disconnect all electric power, including remote 

disconnects before servicing. Follow proper lockout/

tagout procedures to ensure the power can not be 

inadvertently energized. Failure to disconnect power 

before servicing could result in death or serious injury. 

s

s

WARNING

!

Airflow

Turning
Vanes

 

Air Cleaner
 Cabinet

s

s

CAUTION

!

Handle the door only by using the handles on the front of 

the door.  Grasp the door by the handles as depicted in 

Figure 10 to remove and replace the door.  Do not handle 

the door on the edges.  Metal edges may be sharp and 

could result in injury if the door is not handled properly.

Figure 10 Removing Door Assembly 

Summary of Contents for EFD145DLFR000 Series

Page 1: ...t comply with NATIONAL STATE AND LOCAL CODES IMPORTANT This Document is customer property and is to remain with this unit Please return to service information pack upon completion of work Installation...

Page 2: ...heck carefully for any shipping damage This must be reported to and claims made against the trans portation company immediately Check to be sure all major components are in the unit Any missing parts...

Page 3: ...air cleaner to air handler furnace or ductwork please keep screws out of the circled areas The door attaches to the slots in the location Figure 7 Avoiding Screw Interference Supply Plenum Furnace or...

Page 4: ...ions are preferred for greatest efficiency Four inches per linear foot approximately 20 angle should be allowed space permitting 9 Seal all joints in the return air system to prevent dust from enterin...

Page 5: ...R FIELD CHARGER and both COLLECTION CELLS Set the components aside until the cabinet is installed and the indoor unit is in place 2 Install the self adhesive gasket material on the side of the air cle...

Page 6: ...n the side of the air cleaner cabinet flange that will mate with the indoor unit This flange has a double set of holes See Figure 14 UPFLOW AIR HANDLER APPLICATIONS ONLY 9 Position the baffle onto the...

Page 7: ...the indoor unit is in place 2 Install the self adhesive gasket material on the side of the air cleaner cabinet flange that will mate with the indoor unit This flange has a double set of holes See Fig...

Page 8: ...E Wiring penetration must be sealed NOTE For non Trane American Standard Heating Air Conditioning systems order a 120 VAC to 24 VAC transformer KIT BAYTRANS12024 to provide 24 volt power only to the a...

Page 9: ...ndler Figure 20A Wiring Diagram for 24 V Mode NOTE The Black wire must be con nected to chassis ground to ensure proper operation The represents an alpha character BAYTRANS12024 Transformer BLUE GREEN...

Page 10: ...power going into the air handler 2 On the communicating systems air handler remove the blower access panel 3 Remove the communicating control box cover 4 Locate the red jumper wire which is attached f...

Page 11: ...ISCONNECT POWER BEFORE SERVICING COULD RESULT IN DEATH OR SERIOUS INJURY ELECTRICAL CONNECTIONS TO A STANDARD 24 VOLT AIR HANDLER Field wiring O R B YI W1 YO Y2 BK G W2 W3 In Out O R B YI W1 YO G W2 W...

Page 12: ...wire from the air cleaner wire harness to earth ground by attaching the wire to a grounded screw that is connected to the metal air handler chassis or control plate assembly 7 The Green and White wir...

Page 13: ...quick connect terminal to the blue wire and the green wire 9 Attach the blue wire from the air cleaner wiring harness to the open tab on the piggyback terminal supplied in the BAYACCECOMM101 Attach pi...

Page 14: ...with the air cleaner onto the IFC platform where the 35VA transformer was previously located Use the sheet metal screws supplied with the air cleaner to mount the 50VA transformer Reconnect the 115V...

Page 15: ...and RH together Oil burner primary TT contacts must be isolated using field supplied relay RLY00925 or equivalent NOTE 3 The black wire Bk from ACCE unit must be connected to chassis ground to ensure...

Page 16: ...e the wiring diagrams for information on how to attach the wires in a two whole house air cleaner system The figure on the top of page 16 shows the wiring hookup for two whole house air cleaners attac...

Page 17: ...ems 17 Installer s Guide FIELD SUPPLIED 50 VA TRANSFORMER FIELD SUPPLIED 75 VA TRANSFORMER ELECTRICAL CONNECTIONS FOR DUAL WHOLE HOUSE AIR CLEANERS AND FURNACE IN CONVENTIONAL 24V MODE ELECTRICAL CONN...

Page 18: ...IELD CHARGER in the SET UP mode NOTE There is a 10 12 minute delay after the indoor fan operates before the air cleaner starts to operate each time the power to the air cleaner is turned off on This c...

Page 19: ...ER is to capture large particles before they enter the COLLECTION CELLS which allows the collection cells to work more efficiently 1 Turn the air conditioning system off at the Comfort Control thermos...

Page 20: ...a vacuum hose vacuum in even strokes across the length of the PRE FILTER After vacuuming the entire PRE FILTER using even strokes going in one direction repeat the process using even strokes going in...

Page 21: ...R CLEANER 1 Replace the PRE FILTER into the air cleaner Ensure that the AIRFLOW indicator arrow on the PREFILTER is pointing in the same direction as the AIRFLOW indicator arrow on the air cleaner cab...

Page 22: ...ell Identification Alternate Cleaning option for homeowners with 200 or 200 1 COLLECTION CELLS ONLY Vacuuming the PRE FILTER and COLLECTION CELLS restores them to a high efficiency However some enviro...

Page 23: ...and hold the RESET key until the COLLECTION CELL LED turns off 1 to 2 seconds If two air cleaners are connected on the same system reset all timers on both air cleaners at the same time to the same se...

Page 24: ...de View AIRFLOW 27 DEPTH CABINET ADD DOOR DEPTH FOR TOTAL OUTLINE DRAWING FOR UPFLOW FURNACES Dimensions all dimensions in inches I OUTLINE DRAWINGS UPFLOW FURNACE MODEL NUMBERS ifD Air Cleaner A B mu...

Page 25: ...D DOOR DEPTH FOR TOTAL Dimensions all dimensions in inches OUTLINE DRAWING FOR DOWNFLOW FURNACES DOWNFLOW FURNACE MODEL NUMBERS ifD Air Cleaner A B multiple piece cabinet B one piece cabinet EFD17DCLF...

Page 26: ...EPTH CABINET ADD DOOR DEPTH FOR TOTAL OUTLINE DRAWING FOR AIR HANDLERS AIR HANDLER MODEL NUMBERS ifD Air Cleaner A B multiple piece cabinet B one piece cabinet EFD175CLAH000E 17 5 14 9 15 EFD215CLAH00...

Page 27: ...FD175DLFR000 0 05 0 08 0 12 0 17 0 22 0 28 0 34 EFD210DLFR000 0 04 0 06 0 09 0 12 0 15 0 20 0 24 0 29 0 34 EFD245DLFR000 0 03 0 04 0 06 0 09 0 12 0 15 0 19 0 22 0 26 EFD17DDLFR000 0 07 0 11 0 18 0 25...

Page 28: ...idential applications For more information please visit www trane com or www americanstandardair com The manufacturer has a policy of continuous data improvement and it reserves the right to change de...

Reviews: