Operating Instructions CP MEGATHERM DN.A HI

Page 4 / 7

HOM177695627Ien-6

INTERTEC-Hess GmbH · Raffineriestr. 8 · 93333 Neustadt/Donau · Germany · 

 +49 9445 9532-0 ·   [email protected]

Piece

Name

4

M 6x45 cheese-head screws with hex socket

If  one  of  the  components  listed  here  is  not  included  in
the  scope  of  delivery,  then  please  contact  the
manufacturer.

6

Technical Data

Protection class

IP66/IP68 1bar/30min

Rated voltage

max. 250 V AC

Permitted operating voltage

max. 275 V AC

Rated current (in

compliance with VDE 0298)

max. 10 A

Ambient temperature

- 60 to + 60°C

Max. permitted operating

temperature

- 60 to + 180°C

Switching capacity of fault

alarm (AM)

10 A / 275 V AC

Connecting cable

Silicone hose cable,

notch- and oil resistant, 3

x 1,5 mm² Ø8,8 mm

Connecting cable AM

Silicone hose cable,

notch- and oil resistant, 5

x 1,0 mm² Ø8,5 mm

Material

Seawater-proof

aluminium, black

anodized

Mean Time Before Failure

50.000 h

Storage temperature

- 60 to + 80°C

Connecting cable HI

Silicone hose cable,

notch- and oil resistant, 2

x 0,62 mm² and 3 x 1,35

mm², Ø10,2 mm

Special  voltages  with  corresponding  power  adjustment
and component selection are possible.

Profile type "P" Height x

Width x Depth

225 x 229 x 60

mm

Profile type "T" Height x

Width x Depth

325 x 229 x 60

mm

 INFO

You will find the precise technical data for your
instrument on the label.

Rated voltage/Operating voltage

High temperature version

Rated output

Illustration 1: 

Example: CP MEGATHERM DNPA 200 HI label

7

Installation

 WARNING

The heater is only designed for non hazardous
areas.

INTERTEC-Hess GmbH accepts no liability for improper
use.

NOTICE

Carefully remove

When removing from the packaging and during
transport, the connection line must not be stressed or
bent.

For free convection, the heater needs to be installed with
ribs  standing  vertically.  The  minimum  distances  to  the
floor and to devices above it must be complied with. The
label needs to remain legible.

For  the  operation  of  the  device,  it  is  absolutely
necessary  to  connect  an  external  digital  temperature
controller  TC…  in  series  with  the  heater.  The  controller
housing may only be mounted at a place where 80°C is
not  exceeded.  See  separate  operating  instructions  for
series digital temperature controller TC.

To  ensure  operational  safety,  the  heater  must  operate
under temperature conditions which will NOT exceed the
trigger temperature of the limiter.

The operating temperatures must be adhered to.

The  connection  cable  must  be  permanently  installed  up
to  the  inlet  into  the  on-site  junction  box,  taking  the
permissible  bending  radius  =  5  x  outer  diameter  into
consideration.