Default Configuration Text
The following text is loaded into the ZL6100 devices on the EV2 as default settings. Each PMBus command is loaded
via the PowerNavigator software. The # symbol is used for a comment line.
# Configuration file for ZL6100EVAL2Z-Ch1A
#Erase default and user stores
RESTORE_FACTORY
STORE_USER_ALL
STORE_DEFAULT_ALL
RESTORE_DEFAULT_ALL
MFR_ID
Zilker_Labs
MFR_MODEL
ZL6100EVAL2ZR2
MFR_REVISION
Cfg Rev 1.1
MFR_LOCATION
Austin_TX
MFR_DATE
08_27_09
MFR_SERIAL
ch1A
VOUT_COMMAND
1.80
VOUT_DROOP
0.5
VOUT_UV_FauLT_LIMIT
1.53
VOUT_UV_FAULT_RESPONSE
0x80
VOUT_OV_FauLT_LIMIT
2.07
VOUT_OV_FAULT_RESPONSE
0x80
OVUV_CONFIG
0x80
IOUT_SCALE
1.13
IOUT_CAL_OFFSET
1.00
IOUT_OC_FAULT_LIMIT
45.0
IOUT_AVG_OC_FAULT_LIMIT
40.0
IOUT_UC_FAULT_LIMIT
-40.0
IOUT_AVG_UC_FAULT_LIMIT
-40.0
MFR_IOUT_OC_FAULT_RESPONSE
0xBF
MFR_IOUT_UC_FAULT_RESPONSE
0xBF
VIN_OV_FAULT_LIMIT 14.0
VIN_OV_WARN_LIMIT 13.5
VIN_OV_FAULT_RESPONSE 0x80
VIN_UV_WARN_LIMIT 4.641
VIN_UV_FAULT_LIMIT 4.50
VIN_UV_FAULT_RESPONSE 0x80
OT_FAULT_RESPONSE
0xBF
UT_FAULT_RESPONSE
0xBF
POWER_GOOD_ON
1.35
POWER_GOOD_DELAY
10.0
TON_DELAY
15
TON_RISE
5
TOFF_DELAY
15
TOFF_FALL
5
Application Note 1507