Intersan sanispray Repair Manual Download Page 2

IMPORTANT

Sanispray - Individual Sensor Operated

Repair Guide

INTERSAN MANUFACTURING COMPANY

1748 W. Fillmore St. - Phoenix, Arizona 85007 - Tel 602.254.3101 - Fax 602.254.1776 - www.IntersanUS.com

NOTE: THIS INFORMATION IS SUBJECT TO CHANGE WITHOUT FORMAL NOTICE          REV1.2

- 1 -

Always reset the microprocessor(s)
after each intervention (reset button
mounted on the lid of the
microprocessor). After 35 seconds the
unit should be operational.

PROBLEM 1: UNIT CONTINUOUSLY BEEPS WHEN ACTIVATED

 Check and Replace Battery-Pack

Step 1

Open the water-distribution head by using
the supplied key and turning the two locks
counterclockwise. Gently lift and remove the
cover

Step 2

Disconnect the battery by depressing the
battery terminal lock and gently pulling the
two halves apart.

Step 3

a. Test the battery for the proper 10.8       
    voltage.

b. Look for possible loose leads or          
    connections to cause low voltage.

c. Replace the battery. Reverse steps 1 
   & 2. Push the reset button and wait     35
seconds.

Summary of Contents for sanispray

Page 1: ...SANISPRAY Individual Sensor Operated Repair Guide INTERSAN MANUFACTURING COMPANY 1748 W Fillmore St Phoenix Arizona 85007 Tel 602 254 3101 Fax 602 254 1776...

Page 2: ...35 seconds the unit should be operational PROBLEM 1 UNIT CONTINUOUSLY BEEPS WHEN ACTIVATED Check and Replace Battery Pack Step 1 Open the water distribution head by using the supplied key and turning...

Page 3: ...free 3 Supply lines are clean and pressure requirements are within the parameters 4 Thermostatic mixing valve has the correct supply connected to the hot and cold inlets 5 The check valves on the elbo...

Page 4: ...ssor and separate lid from the base The problem should travel with the nonworking sensor and the adjacent sensor should activate the solenoid valve Replace the defective sensor with a new one If not c...

Page 5: ...rt on the water part of the valve Insert 4 round head solenoid screws and tighten firmly 4 Check Solenoid Valve Step 3 Remove the solenoid valve leads from the solenoid valve by gently pulling straigh...

Page 6: ...ssor Step 1 Follow steps 1 2 3 4 from the sensor checking Step 2 Check that all the connections are secure Step 3 Disconnect the battery by depressing the battery terminal lock and gently pulling the...

Page 7: ...AGNOSTICS HAVE DETERMINED THE NECESSITY TO REPLACE THE MICROPROCESSOR PROBLEM 4 CONTINUOUS WATER FLOW Check Solenoid Valve In some cases the filters may not be enough to eliminate the debris from jamm...

Page 8: ...f battery connector Date of installation Environment where unit is installed How the unit is used 3 To order replacement parts or to receive parts prices please contact your local rep 4 Use only Inter...