IMPORTANT
Sanispray - Individual Sensor Operated
Repair Guide
INTERSAN MANUFACTURING COMPANY
1748 W. Fillmore St. - Phoenix, Arizona 85007 - Tel 602.254.3101 - Fax 602.254.1776 - www.IntersanUS.com
NOTE: THIS INFORMATION IS SUBJECT TO CHANGE WITHOUT FORMAL NOTICE REV1.2
- 1 -
Always reset the microprocessor(s)
after each intervention (reset button
mounted on the lid of the
microprocessor). After 35 seconds the
unit should be operational.
PROBLEM 1: UNIT CONTINUOUSLY BEEPS WHEN ACTIVATED
Check and Replace Battery-Pack
Step 1
Open the water-distribution head by using
the supplied key and turning the two locks
counterclockwise. Gently lift and remove the
cover
Step 2
Disconnect the battery by depressing the
battery terminal lock and gently pulling the
two halves apart.
Step 3
a. Test the battery for the proper 10.8
voltage.
b. Look for possible loose leads or
connections to cause low voltage.
c. Replace the battery. Reverse steps 1
& 2. Push the reset button and wait 35