17
Set-Up
The
SE-200’s SET-UP menu allows you to make several
important initial settings. Typically, most of these
settings are only made once and don’t have to be changed.
The keel offset adjustment is a good example.
The
SET-
UP menu is shown at right and the following paragraphs
describe each choice in detail.
Language/Units
The
SE-200 allows the choice of several operating
languages and conversions for distance, speed and
temperature. To select the operating language or choose
the unit conversion to use, press the button labeled
LANGUAGE/UNITS. A display window as shown at
left will pop up on the screen showing the available
languages and unit conversions and the ones which are
currently selected.
Use the softkeys to highlight your desired choice for
language, units for range, temp and speed. When finished
press the
EXIT softkey to save your selection and exit this
menu.
More - Max Gain, Choose Boat Icon
Press the softkey below the
MORE choice to bring up a
menu to set the
MAXIMUM GAIN/range, and boat icon,
or press
MORE to adjust the STC to minimize the effect
of surface clutter and select the
System Software.
To adjust the
MAX VERT GAIN*, use the softkey to
highlight the desired range - then use the
NAV
(UP/
DOWN) buttons to adjust the Max Gain.
When finished with all settings, press the
EXIT symbol to
save your selections and exit the menu.
STC Adjustment
The
STC Adjustment can be used to help minimize
surface clutter problems. Typically, most depthsounders
show a band of noise near the surface caused by ringing in
the transducer, surface turbulence in the water and other
factors. Where there is severe surface clutter, the digital
depth display can get confused between showing the true
bottom or the surface clutter. In addition, severe surface
clutter can cause the alarms to sound.
English
French
Spanish
German
Chinese
Korean
Greek
Danish
Ft.
Fa.
M
o
F
o
C
MPH
Km/Hr
Knots
RANGE
SUGGESTED
MAX GAIN
SETTING
0 - 50 Ft
14
0 - 100 Ft
16
0 - 200 Ft
18
0 - 400 Ft
22
0 - 800 Ft
24
0 - 1,200 Ft
31
The SE-200 allows you to customize the maximum possible vertical scan gain
for each range. The table below shows a suggested range of Max Gain settings
that you can set. Too much gain on the shallow ranges will cause excess noise
and false forward targets.
EXIT LANGUAGE TRANSDUCER DEMO MORE
UNITS
FORWARD LOOOKING SONAR ENGINE
90 Horiz Scan &
90 Vertical Scan
Version 1.0
200khz
FT
M
VERT
MAX GAIN
50
12
14
100
32
16
200
70
14
FA
10
20
40
MORE
Summary of Contents for Sonar Engine SE-200