Table 2 – Altitude Derate Multiplier for U.S.A.
ALTITUDE
PERCENT
OF
DERATE
DERATE
MULTIPLIER
FACTOR*
FT.
M
0–2000
0
−
610
0
1.00
2001–3000
610
−
914
4
−
6
0.95
3001–4000
914
−
1219
6
−
8
0.93
4001–5000
1219
−
1524
8
−
10
0.91
5001–6000
1524
−
1829
10
−
12
0.89
6001–7000
1829
−
2134
12
−
14
0.87
7001–8000
2134
−
2438
14
−
16
0.85
8001–9000
2438
−
2743
16
−
18
0.83
9001–10,000
2743
−
3048
18
−
20
0.81
*Derate multiplier factors are based on midpoint altitude for altitude range.
ON/OFF Switch
Regulator Seal Cap
Regulator Adjustment
Regulator Seal Cap under Cap
1/2” NPT Outlet
1/8” NPT Manifold
Pressure Tap
1/8” NPT Inlet
Pressure Tap
1/2” NPT Inlet
SINGLE-STAGE
A11153
Figure 3
−
Gas Valve
R Y W G
10 TURNS
THERMOSTAT SUBBASE
TERMINALS WITH
THERMOSTAT REMOVED
(ANITICIPATOR, CLOCK, ETC.,
MUST BE OUT OF CIRCUIT.)
HOOK-AROUND
AMMETER
EXAMPLE: 5.0 AMPS ON AMMETER
10 TURNS AROUND JAWS
= 0.5 AMPS FOR THERMOSTAT
ANTICIPATOR SETTING
FROM UNIT 24-V
CONTROL TERMINALS
A96316
Figure 4
−
Amp. Draw Check with Ammeter