Maintenance and Care for the Equipment Owner

Before performing equipment maintenance

yourself, please

carefully consider the following:

FIRE, EXPLOSION, ELECTRICAL SHOCK AND

CUT HAZARD

Failure to follow this warning could result in personal

injury, death or property damage.

1. Turn off gas supply first, then all electrical power to your

unit and install lock--out tag before servicing or per-

forming maintenance.

2. When

removing

access

panels

or

performing

maintenance functions inside your unit, be aware of

sharp sheet metal parts and screws. Although special care
is taken to reduce sharp edges to a minimum, be

extremely careful when handling parts or reaching into
the unit. Wear safety glasses, gloves, and appropriate
protective clothing.

!

WARNING

Air Filters

The air filter(s) should be checked every 3 or 4 weeks and

changed or cleaned whenever it becomes dirty. Dirty filters
produce excessive stress on the blower motor and can cause the

motor to overheat and shut down.
This unit must have air filters in place before it can be operated.

These filters can be located in one of at least two places. In many
applications, the installer will provide return air filter grilles

mounted on the wall or ceiling of the conditioned structure. In the

instance of filter grilles, the filters can simply be removed from the
grille and replaced.
The other typical application is an accessory filter rack installed
inside the unit itself. The following information is given to assist in

changing filters used in these internal filter racks.
Filter kits are available as a purchased accessory or a factory
installed option. The same filter kit is included with the accessory

economizers and factory installed economizers.

Table 1 – Replacement Filter Sizes

Unit Size

Filter Size

30-040/060

2 each 20 x 12 x 1

(508 x 305 x 25 mm)

36-060/090

2 each 20 x 12 x 1

(508 x 305 x 25 mm)

42-060/090

1 each 24 x 14 x 1 (610 x 356 x 25 mm),

24 x 16 x 1 (610 x 406 x 25 mm)

48-090/115/130

1 each 24 x 14 x 1 (610 x 356 x 25 mm),

24 x 16 x 1 (610 x 406 x 25 mm)

60-090/115/130*

1 each 24 x 16 x 1 (610 x 406 x 25 mm),

24 x 18 x 1 (610 x 457 x 25 mm)

*Units with bent indoor coil.

To replace or inspect filters in accessory filter rack (See Fig. 2):

1. Remove the filter access panel using a 5/16--in. nut driver.
2. Remove the filter(s) by pulling it out of the unit. If the

filter(s) is dirty, clean or replace with a new one.

When installing the new filter(s), note the direction of the airflow
arrows on the filter frame which should be pointing at the indoor

coil.

3. Reinstall filter access panel ensuring opening is air and

water tight.

If you have difficulty locating your air filter(s) or have questions

concerning proper filter maintenance, contact your dealer for
instructions. When replacing filters, always use the same size and

type of filter that was supplied originally by the installer. See Table
1 for filter sizes supplied with accessory filter rack.

Replacing or inspecting filters in units with econom-

izers

Small Chassis (See Fig. 8)

1. Remove return air duct cover at rear of unit using a 5/16--in.

nut driver.

2. Remove the filter(s) by pulling it out and through the unit

duct opening. If filter is dirty, replace both filters with new
ones.

When installing the new filters, note the direction of the airflow
arrows on the filter frame, which should be pointing at the indoor

coil.

3. Reinstall duct cover ensuring opening is air and watertight.

Large Chassis (See Fig. 9)

1. Remove filter access door using a 5/16--in. nut driver.
2. Remove the filter(s) by pulling it out and through the unit

filter access door. If filter is dirty, replace both filters with

new ones.

Units with bent indoor coils, install 24 x 18 x 1 (610 x 457 x 25

mm) filter first and then install 24 x 16 x 1 (610 x 406 x 25) filter.
When installing the new filters, note the direction of the airflow

arrows on the filter frame, which should be pointing at the indoor
coil.

3. Reinstall filter access door ensuring opening is air and water

tight.

UNIT OPERATION HAZARD

Failure to follow this caution may result in

property

damage.
Never operate your unit without filters in place. An

accumulation of dust and lint on internal parts of your unit

can cause loss of efficiency and blower motor and/or

compressor damage.

!

CAUTION

Summary of Contents for PGD3 Series

Page 1: ...f model _____________________________________________ _____________________________________________ _____________________________________________ INSTALLATION INFORMATION Date Installed_______________...

Page 2: ...Only trained and qualified personnel should install repair or service this equipment WARNING FIRE EXPLOSION HAZARD Failure to follow this warning could result in personal injury death and or property...

Page 3: ...rs do not light within 15 minutes of the initial call for heat there is a lockout 11 Set the temperature selector on room thermostat to desired setting FIRE AND EXPLOSION HAZARD Failure to follow this...

Page 4: ...e With the SYSTEM control set to COOL your unit will run in cooling mode until the indoor temperature is lowered to the level you have selected On extremely hot days your unit will run for longer peri...

Page 5: ...301 Specifications are subject to change without notice 55 STEP 1 STEP 2 CL O S E STEP 3 OFF ON MAIN STEP 4 STEP 7 OFF ON MAIN STEP 8 STEP 5 72 STEP 10 STEP 6 STEP 9 O P E N A07662 Fig 4 To Start Unit...

Page 6: ...ject to change without notice 55 STEP 1 STEP 2 CL O S E STEP 3 OFF ON MAIN STEP 4 STEP 6 STEP 5 A07663 Fig 5 To Shut off Unit Gas Heat 90 STEP 1 STEP 2 CL O S E 72 STEP 4 5 OFF ON MAIN STEP 3 A09194 F...

Page 7: ...5 mm 48 090 115 130 1 each 24 x 14 x 1 610 x 356 x 25 mm 24 x 16 x 1 610 x 406 x 25 mm 60 090 115 130 1 each 24 x 16 x 1 610 x 406 x 25 mm 24 x 18 x 1 610 x 457 x 25 mm Units with bent indoor coil To...

Page 8: ...for any required service Electrical Controls and Wiring Electrical controls are difficult to check without proper instrumentation If there are any discrepancies in the operating cycle contact your lo...

Page 9: ...r connection 11 Inspection for leaks in the refrigerant circuit Pressure check to determine appropriate refrigerant charge 12 Operational check of the unit to determine working conditions Repair or ad...

Page 10: ...10 50902340301 Specifications are subject to change without notice Copyright 2016 International Comfort Products Lewisburg TN 37091 USA Replaces 50902340300...

Reviews: