32801000401
9
Specifications subject to change without notice.
INDOOR INSTALLATION CONSOLE SIZES 18−58
1. Install Ø10 hanging screw bolts (4) (refer to Figures 12 and 13
for the correct hanging screw bolt distance).
Fig. 12
-
Install the hanging screw bolts
Fig. 13
-
Blade shape and slide insertion
2. Evaluate the ceiling construction and install Ø10 hanging screw
bolts (4).
!
CAUTION
Consult with on−site construction personnel for the
specific ceiling construction. The installation location
must be flat.
Cut of the roof beam. Strengthen the location that has
been cut off and consolidate the roof beam to avoid any
vibration.
DRILL A HOLE IN THE WALL FOR THE
INTERCONNECTING PIPING, DRAIN AND WIRING
1. For maximum serviceability, it is recommended that you have
the refrigerant line, flare connection and the drain connection on
the outside of the wall so the fan coil can be mounted.
a. Determine the pipe hole position.
b. Drill the pipe hole. The outside pipe hole is 1/2 in. (13 mm)
lower than the inside pipe hole, therefore it slants slightly
downward (see Fig. 14).
Fig. 14
-
Drill holes
2. Remove the side boards and the grille (see Fig. 15).
Fig. 15
-
Remove the side boards and the grille
3. Locate the hanging arm on the hanging screw bolt (see Fig. 16).
Fig. 16
-
Locate the hanging arm
4. Install the unit (see Figures 18 and 19).
Fig. 17
-
Install the unit
Fig. 18
-
Ceiling installation