background image

6-Pin PRPC Connector Pin-Out Definition 

Connector J18 contains 6 of the PRPC’s 11 fused output pins.  These 6 fused output pins are 
connected to 4 configurable relay outputs.  Each relay output is capable of 15 Amps maxi-
mum. Configurable relay output 4 is shared by fuses 4A, 4B, and 4C.  When added together 
the sum of these three fuses must not exceed 20 Amps. Note that the placement of fuse 3 
will determine whether the output is active high or active low.  The use of fused outputs 4A, 
4B, or 4C is recommended for higher current loads.  

The PRPC module has an absolute 

maximum current rating of 65 Amps. 
 
 

 
 
 
 
 
 
 
 
The 6 fused output pins on connector J18 are defined as follows: 

• 

Pin #1 (White wire) Configurable Relay Output 4, Fuse 4C, Active High

 

• 

Pin #2 (White wire) Configurable Relay Output 4, Fuse 4B, Active High 

• 

Pin #3 (White wire) Configurable Relay Output 4, Fuse 4A, Active High 

• 

Pin #4 (White wire) Configurable Relay Output 3, Fuse 3,  

     Fuse Selectable Active High/Low  

• 

Pin #5 (White wire) Configurable Relay Output 2, Fuse 2, Active High  

• 

Pin #6 (White wire) Configurable Relay Output 1, Fuse 1, Active High 

 

 

Connect the desired outputs to vehicle equipment as needed.  Tape up unused leads.   

6 Pin Output  

Back of Connector

 

InterMotive Inc. 
13395 New Airport Rd.  
Auburn, CA 95602 

Phone: (530)-823-1048 

Fax: (530)-823-1516 

Page 6 of 13

 

www.intermotive.net 

 [email protected] 

PRPC501-A-090314-INS  

The default configuration for the relay outputs on J18 are as follows: 

 

• 

Pin #1 (White wire),   

• 

Pin #2 (White wire),         

• 

Pin #3 (White wire),  

 

• 

Pin #4 (White wire),  Left Turn Signal On

 

• 

Pin #5 (White wire),  Key On

 

• 

Pin #6 (White wire),  Low Beams or High Beams 

2-Pin PRPC Connector 

Connector J20 contains the two black ground wires for relay output fuse sensing, 
motor reversing, and low true relay outputs. This is not an optional connection. The 
wires in this connector must be attached to a good chassis ground for the system to 
function properly. 

Right Turn Signal On 

Summary of Contents for PRPC501-A

Page 1: ...be used This could drive a high temperature dash indicator Another output could be programmed to drive a warning buzzer lamp when the vehicle speed exceeds some limit such as 70mph Electric doors can...

Page 2: ...in stalled in 2 Click the Create Configuration button 3 This screen will come up 4 Configure as desired See the following page for more infor mation Press the Enter button after each entry Note CTO ca...

Page 3: ...using a momentary button as the only input condition and setting the Delays to zero Thus a load could be turned on by pushing a momentary button and turned back off by pushing the button a second time...

Page 4: ...ab and click on Device Manager In the De vice Manager window expand the Ports menu and the download cable will display as USB Serial Port Click the Open File button 1 Open the PRPC ims or configuratio...

Page 5: ...s to mount the module InterMotive Inc 13395 New Airport Rd Auburn CA 95602 Phone 530 823 1048 Fax 530 823 1516 Page 5 of 13 www intermotive net products intermotive net PRPC501 A 090314 INS PRPC Power...

Page 6: ...ctive High Pin 4 White wire Configurable Relay Output 3 Fuse 3 Fuse Selectable Active High Low Pin 5 White wire Configurable Relay Output 2 Fuse 2 Active High Pin 6 White wire Configurable Relay Outpu...

Page 7: ...added together the sum of these fuses must not exceed 20 Amps Note that the placement of fuse 6 will determine whether the output is active high or active low The use of fused outputs 5A or 5B is rec...

Page 8: ...onfigurable Output Active Low Connect the desired outputs to vehicle equipment as needed Tape up unused leads When connecting to relays use relays with appropriate kick back suppression such as Digike...

Page 9: ...lue White stripe Input 7 Active low Pin 8 Pink Black stripe Input 8 Active low Pin 9 Black White stripe Input 9 Active low Pin 10 Orange Black stripe Input 10 Active low Pin 11 Tan Black stripe Input...

Page 10: ...nk harness 6 pin connector is NOT connected to the PRPC501 module 2 Turn the vehicle key on engine off 3 Insert the Data Link harness 6 pin connector into the PRPC501 module 4 The PRPC s red fuse LEDs...

Page 11: ...tput the associated on board red LED will illuminate No fuse sensing is done on outputs that are not configured to turn on Low Current Outputs To enter LCO diagnostic mode momentarily press the red te...

Page 12: ...e on board red fuse LED s will light when a corresponding Input is active Fuse LED 1 2 3 4A 4B 4C 5A 5B Input 1 2 3 4 5 6 7 8 J3 Pin 1 2 3 4 5 6 7 8 6 9 9 7 10 10 8 12 12 Scrolling LED s This may indi...

Page 13: ...the PRPC fails any step in the Post Installation Test review the installation instructions and the loaded configuration by running the Graphical User Interface application If necessary call InterMotiv...