SECTION 3
Scanner Specifications
3-12 SE 1223 Scanner User’s Guide
SE 1223 Long Range (LR) Scanner
Decode Zone
The SE 1223 LR scanner decodes the symbols as described
in Table 3-8. The numbers shown are typical values as well
as guaranteed values. The minimum element width (or
symbol density) is the width in mils of the narrowest ele-
ment (bar or space) in the symbol.
Table 3-8
SE 1223 Standard Scanner Decode Distances
Typical
Guaranteed
Symbol Density
Minimum
Maximum
Minimum
Maximum
In.
mm
In.
cm
In.
cm
In.
cm
In.
cm
0.010
0.254 9
22.86
22
55.88
12
30.48
18
45.72
0.015
0.381 7.5
19.05
39
99.06
9
22.86
34
86.36
0.020
0.508 7
17.78
44
111.76
9
22.86
39
99.06
0.040
1.01
10
25.4
90
228.6
10
25.4
80
203.2
0.055
1.04
10
25.4
100
254.0
10
25.4
90
228.6
0.070*
1.79
60
152.4
180
457.2
70
177.8
162
411.48
0.100*
2.54
66
167.64
240
609.6
84
213.36
210
533.4
* Reflective symbol.
The decode zone is a function of various symbol characteris-
tics including density, print contrast, wide-to-narrow ratio,
and edge acuity. Width of decode zone at any given distance
must be considered when designing a system.
Usable scan length is calculated as follows:
L = 1.8 x (D + d) x Tan (A/2)