background image

5 Setup

MaxiScan 1000 - Integration Guide

   25

Basic setup

You can set up your M1000 in a test configuration by scanning configuration bar
codes. Follow the instructions in this section.

Basic setup does not include all the configuration possibilities of the M1000. For a
complete setup, use the EasySet System configuration software (see the 

Online setup

with EasySet 

section).

Plug in power supply

System power ON

Reset factory defaults (optional)

\46\42\60

Summary of Contents for MaxiScan 1000

Page 1: ...Integration Guide Manual MaxiScan1000 CCDScanEngine P N 3 380049 01...

Page 2: ...Technologies Corporation does not assume any product liability in connection with integrating this component within any sub assembly system or application The information contained in this document i...

Page 3: ...tallation 9 Fixing in position Dimensions Mounting a window 3 Connections 12 Connector and pinouts Optional adaptor cable PC connection example External buzzer connection External LED connection Input...

Page 4: ...4 MaxiScan 1000 Integration Guide...

Page 5: ...s suitable for a wide range of retail and industrial applications This Integration Guide explains how to install and set up your M1000 You can use the EasySet setup software to set up the M1000 See th...

Page 6: ...e the Reading distance section Setup Test the setup before you install the M1000 permanently Symbologies Use standard symbologies best suited to your application some symbologies Interleaved 2 of 5 fo...

Page 7: ...or fixed device in any orientation Tilt Prevents reading of a bar code if all the bars are not inside the reading beam no read read OK tilt good read Pitch Reduces bar width and is much more critical...

Page 8: ...Scan 1000 Integration Guide Skew Reduces bar height Reading may be possible with a skew angle up to 65 Reduce skew to increase reading efficiency A small skew angle 2 3 minimum is good as it prevents...

Page 9: ...MaxiScan 1000 Integration Guide 9 2 Installation Fixing in position 1 1 plastic M2 2 mm...

Page 10: ...2 Installation 10 MaxiScan 1000 Integration Guide Dimensions 4 2 cm 1 65 4 8 cm 1 89 0 35 cm 0 14 0 35 cm 0 14 0 25 cm 0 1 4 7 cm 1 85 5 65 cm 2 22 2 73 cm 1 07 1 66 cm 0 65 4 7 cm 1 85...

Page 11: ...or the performance of your M1000 Recommended window angle 30 from vertical in either direction An anti reflection coating increases performance and permits a lower window angle Recommended maximum wav...

Page 12: ...3 384034 00 pin 1 reserved reserved ground TX reserved good read LED external buzzer external sync in sync out removed 5V RTS RX CTS reserved for download reserved for download reserved version RS 23...

Page 13: ...zzer P N 3 384034 00 M1000 14 pin connector Stewart 10 pin socket PC DB9 connector PC DB25 connector 1 removed 2 ground 10 ground 5 ground 7 ground 3 5V 1 5V 4 TX 4 TX 2 RXD PC input 3 RXD PC input 5...

Page 14: ...read buzzer parameters can be set from EasySet The buzzer must not have an integrated oscillator buzzer with external drive circuitry 30 mA max 5V MaxiScan 51 pin 10 470 nF External LED connection Th...

Page 15: ...til it receives a stop character or timeout according to setup The start and stop characters are user programmable This software trigger can be combined with any of the above See EasySet for more deta...

Page 16: ...Integration Guide Examples Input synchronization triggering by an opto coupled cell M1000 pin 12 10 k pin 2 Photelectric sensor 5 V 5 V 4 7 k Vcc Output synchronization 30 mA max M1000 pin 14 4 7 k pi...

Page 17: ...ce section below Pitch 70 Skew 65 Scan performance Print contrast ratio 25 minimum Light source 4 LEDs at 640 nm Optical characteristics Image sensor High resolution CCD Power requirements 5 VDC 5 Ele...

Page 18: ...3 3 9 3 5 3 1 2 8 2 4 2 0 1 6 1 2 0 8 0 4 0 cm 0 1 mm 4 mil 0 3 mm 12 mil 0 2 mm 8 mil 1 0 mm 40 mil 0 5 mm 20 mil 2 8 2 4 2 0 1 6 1 2 0 8 0 4 0 0 4 0 8 1 2 1 6 2 0 2 4 2 8 This chart shows the horiz...

Page 19: ...to make a custom cable 3 380029 00 RS 232 TTL adaptor cable with Stewart 10 pin socket compatible with RS 232 C cable This cable includes a buzzer 3 384034 00 Cables RS 232 C cable compatible with RS...

Page 20: ...st way to set up your M1000 You can download your custom settings directly to the M1000 or print out and scan the corresponding configuration bar codes If you want to configure your M1000 dynamically...

Page 21: ...command System power ON Plug in power supply Set the COM port parameters to 19200 baud 8 data bits no parity Start EasySet EasySet Refer to the EasySet online help for a detailed explanation of how to...

Page 22: ...checksum section below display data string 46 4E 60 This mode remains active until you switch off the M1000 Example command Code 39 active 41 4C 60 5E 5E checksum 2 Remove the backslash separator char...

Page 23: ...0x60 weight 1 1 2 3 weight value 1 0x68 1 0x41 2 0x4C 3 0x60 0x261 3 Calculate the modulo 103 value modulo 67 hex of the sum 0x261 modulo 0x67 0x5E checksum 0x261 0x67 0x5 with remainder 0x5E 4 Add t...

Page 24: ...0x03 0x6A hex format debug slave mode 4 5 5 0 6 0 ASCII format Optional beep command for use with your application This command sends one or more beeps to the M1000 to indicate successful or unsuccess...

Page 25: ...uration bar codes Follow the instructions in this section Basic setup does not include all the configuration possibilities of the M1000 For a complete setup use the EasySet System configuration softwa...

Page 26: ...5 Setup 26 MaxiScan 1000 Integration Guide Select baud rate default value 1200 41 04 60 2400 41 05 60 4800 41 06 60 9600 41 07 60 19200 41 08 60 38400 41 09 60 Select data bits 7 42 60 8 43 60...

Page 27: ...MaxiScan 1000 Integration Guide 27 Select parity even 46 01 60 odd 46 02 60 none 46 00 60 Select stop bits 1 44 60 2 45 60 Select postamble none 45 54 3E 00 60 Carriage Return Line Feed 45 54 3E 0D 3...

Page 28: ...11 Select symbologies Codabar minimum length 6 41 52 60 Code 39 41 4C 60 Code 128 EAN 128 41 5A 60 Interleaved 2 of 5 minimum length 6 41 4E 60 Standard 2 of 5 minimum length 6 41 50 60 UPC A UPC E E...

Page 29: ...Guide 29 12 Test symbologies Code 39 CODE 39 Code 128 CODE 128 Interleaved 2 of 5 12345678901234 Standard 2 of 5 123456 EAN 13 1234567890128 UPC A 0 0 1 2 3 4 5 0 0 0 0 7 Codabar 123456 PDF417 Interme...

Reviews: