3 Connections
14
MaxiScan 1000 - Integration Guide
External buzzer connection
The good read buzzer parameters can be set from EasySet. The buzzer must not
have an integrated oscillator.
buzzer with external
drive circuitry
(30 mA max)
+ 5V
MaxiScan
51
Ω
pin 10
470 nF
External LED connection
The good read LED can be deactivated from EasySet.
+ 5V
LED (20 mA max)
MaxiScan
220
Ω
pin 8