Intermec EasyCoder 601 XP – Installation & Operation Ed. 3
105
Appendix 3
Communication Cables
Serial Interface
The EasyCoder 601 XP has – as standard – one serial communica-
tion interface: RS 232C on "uart1:".
Protocol
Default setup:
Baudrate:
9600
Char. length
8 bits
Parity:
None
Stop bits:
1
RTS/CTS
Disabled
ENQ/ACK:
Disabled
XON/XOFF: Disabled (both ways)
New Line:
CR/LF
To change the serial interface settings, see chapter 7 “Setting Up
the Printer”.
Interface Cable
Computer end:
DB9 or DB 25 female connector (PC)
Printer end:
DB25 female connector
Host
EasyCoder 601 XP
Host
Signal
DB-9 DB-25
Signal
DB-25 DB-25
Signal
1
1
1
1
shield
RXD
2
2
TXD
2
3
RXD
TXD
3
3
RXD
3
2
TXD
CTS
8
4
RTS
4
5
CTS
RTS
7
5
CTS
5
4
RTS
6
DSR
6
20
DTR
GND
5
7
Signal GND
7
7
GND
16
+ 5V
1
16
DSR
6
20
DTR
20
6
DSR
22
RI
22
1
/. The ex5V is limited to 200 mA and is automatically turned
off at overload. It is intended to drive e.g. an external alphanumeric