background image

Testing the Interface Card

5

Testing the Interface Card

Note: For the following test to work properly, you must first complete the procedure
under “Installing the Coax/Twinax Card.”

1. Turn off the printer, set the interface card rotary switch to position 7 (perform

self-test), and then turn on the printer. The printer prints the interface card self-test
label.

2. Turn off the printer, set the interface card rotary switch to position 0 (set twinax

cable address), and then turn on the printer.

3. Turn off the printer, set the interface card rotary switch to position A (normal

operation), and then turn on the printer. The interface card and the printer are now
ready to communicate with the host system.

Jumper and DIP Switch Settings

This section provides the definitions for the jumper and DIP switch settings on the
coax/twinax interface card.

Jumper Settings

By opening or closing jumper 1, you can select the label format.

Jumper 1: Output Label Format

Setting

Format

Open

With DIP switch 2, selects either Roman 8 (DIP switch 2 off) or Code Page 850
(DIP switch 2 on). Open is the default setting for the 501XP and 601XP printers.

Closed

With DIP switch 2, selects either Intermec-compatible Latin 1 (DIP switch 2 off)
or IBM Latin 1 (DIP switch 2 on). Closed is the default setting for the 3XXX and
44XX printers.

Note: Use Intermec-compatible Latin 1 only when replacing the Intermec twinax card,
Part No. 057029-004, or the Intermec coax card, Part No. 057026-004, with the
coax/twinax interface card.

DIP Switch Settings

The printer reads the DIP switches when you turn on the printer and set the output port
and factory default settings. The factory default settings are listed in the following
table:

Card

Default settings

Coax

Intermec-compatible Latin 1 with multinational character set or Roman 8 with
U.S.A./Canada character set and Coax Buffer 1920

Twinax

Intermec-compatible Latin 1 with multinational character set or Roman 8 with
U.S.A./Canada character set and 5256M1 Printer ID

Summary of Contents for 67879

Page 1: ...and host Jumper and DIP Switch Settings This section describes the different jumper and DIP switch settings Making the Coax Twinax Interface Card Backward Compatible This section explains how to set t...

Page 2: ...cover upward to release it from the printer frame and lift the media cover away from the top of the printer 3 Take out the three screws securing the PCB cover to the main deck and the three screws sec...

Page 3: ...he printer COAXTWINI 003 PCB cover Media cover Installing the Coax Twinax Interface Card 1 Remove the plate covering the coax twinax interface card expansion slot on the back panel of the printer 2 Se...

Page 4: ...a 3XXX or 44XX Printer J23 Cutter Coax twinax interface card Plate Screw 2 places Coax twinax connector J3 COAXTWINI 002 Back panel Installing the Coax Twinax Interface Card in a 501XP or 601XP Printe...

Page 5: ...ou can select the label format Jumper 1 Output Label Format Setting Format Open With DIP switch 2 selects either Roman 8 DIP switch 2 off or Code Page 850 DIP switch 2 on Open is the default setting f...

Page 6: ...character set coax command 08 and twinax command 05 To use these commands to set the country character set you must set DIP switch 2 to the on position DIP Switch 1 Active Output Port Selection Settin...

Page 7: ...Off Off 5 Canada France 276 5 Brazil 275 Off On Off On 6 Denmark Norway 277 6 Canada France 276 Off On On Off 7 Finland Sweden 278 7 Denmark Norway 277 Off On On On 8 France 297 8 Denmark Norway alt...

Page 8: ...No 057029 004 1 Set the DIP switches and jumpers to the following settings Switch Jumper Position Comment DIP switch 1 On Intermec custom port DIP switch 2 Off Intermec compatible Latin 1 DIP switche...

Page 9: ...ecs Control Code Parse Yes Character Set INTERMEC ROM OK RAM OK 3 Keep the configuration label and turn off the printer 4 Turn off the printer set the rotary switch to position A and turn on the print...

Page 10: ...6001 36th Avenue West P O Box 4280 Everett WA 98203 9280 1998 Intermec All Rights Reserved P N 067871 001...