background image

Coax/Twinax Interface Card Service Technician Instructions

2

Preparing a 3XXX or 44XX Printer

1. Turn off the printer and remove the AC power cord from the printer.

2. Pull the bottom of the media cover away from the base of the printer, lift the front

of the media cover upward to release it from the printer frame, and lift the media
cover away from the top of the printer.

3. Take out the three screws securing the PCB cover to the main deck and the three

screws securing the PCB cover to the base of the printer.

4. Pull the bottom of the PCB cover away from the base of the printer, slide the top of

the PCB cover away from the main deck, and lift the PCB cover away from the
printer.

COAXTWINI .004

J23

Cutter

PCB
cover

Media
cover

Summary of Contents for 67879

Page 1: ...and host Jumper and DIP Switch Settings This section describes the different jumper and DIP switch settings Making the Coax Twinax Interface Card Backward Compatible This section explains how to set t...

Page 2: ...cover upward to release it from the printer frame and lift the media cover away from the top of the printer 3 Take out the three screws securing the PCB cover to the main deck and the three screws sec...

Page 3: ...he printer COAXTWINI 003 PCB cover Media cover Installing the Coax Twinax Interface Card 1 Remove the plate covering the coax twinax interface card expansion slot on the back panel of the printer 2 Se...

Page 4: ...a 3XXX or 44XX Printer J23 Cutter Coax twinax interface card Plate Screw 2 places Coax twinax connector J3 COAXTWINI 002 Back panel Installing the Coax Twinax Interface Card in a 501XP or 601XP Printe...

Page 5: ...ou can select the label format Jumper 1 Output Label Format Setting Format Open With DIP switch 2 selects either Roman 8 DIP switch 2 off or Code Page 850 DIP switch 2 on Open is the default setting f...

Page 6: ...character set coax command 08 and twinax command 05 To use these commands to set the country character set you must set DIP switch 2 to the on position DIP Switch 1 Active Output Port Selection Settin...

Page 7: ...Off Off 5 Canada France 276 5 Brazil 275 Off On Off On 6 Denmark Norway 277 6 Canada France 276 Off On On Off 7 Finland Sweden 278 7 Denmark Norway 277 Off On On On 8 France 297 8 Denmark Norway alt...

Page 8: ...No 057029 004 1 Set the DIP switches and jumpers to the following settings Switch Jumper Position Comment DIP switch 1 On Intermec custom port DIP switch 2 Off Intermec compatible Latin 1 DIP switche...

Page 9: ...ecs Control Code Parse Yes Character Set INTERMEC ROM OK RAM OK 3 Keep the configuration label and turn off the printer 4 Turn off the printer set the rotary switch to position A and turn on the print...

Page 10: ...6001 36th Avenue West P O Box 4280 Everett WA 98203 9280 1998 Intermec All Rights Reserved P N 067871 001...

Reviews: