background image

INTERNAL WIRING - MODEL RC2123PT

PULSE

SWITCH

RELAY

GRAY

BLUE

BROWN

WHITE

BLACK

         N  L

      INPUT

LO HI  FRZ

2 SPEED

PUMP

TROUBLESHOOTING

 

 

SYMPTOM 

CAUSE(S) 

CORRECTIVE ACTION

1. Pump will not operate or operates 

1a. Air hose disconnected 

Check hose connections.

  on low speed only. 

1b. Defective air button 

Replace air button - see note 1.

   

1c. Water in air hose 

Blow-out air hose - see note 2.

   

1d. Defective pulse switch 

Replace pulse switch - see note 2.

   

1e. Defective relay 

Replace relay - see note 3.

   

1f.  Air button is too far 

Install larger air button.

2. Pump will not turn off or operates 

2a. Air hose disconnected 

Check hose connections.

  on high speed only. 

2b. Defective air button 

Replace air button - see note 1.

   

2c. Defective relay 

Replace relay - see note 3.

3. Pump turns on/off by itself. 

3a. Defective pulse switch 

Replace pulse switch.

   

3b. Water in air hose 

Blow-out air hose - see note 2.

   

3c. Changing air pressure in air hose 

Reroute air hose.

4. Blank Timer Display during power 

4a. Dead battery 

Replace battery.

  failure

NOTES

A Pneumatic Remote Control (Air Switch) consists of an air button (air pump, transmitter), a pulse switch (air 

Sensor, receiver) and a relay (either alternate action or stepper). The air button is connected to the pulse 

switch by the air hose. By pressing on the air button at one end of the air hose, the increased pressure will 

momentarily close the contacts of the pulse switch at the other end of the air hose, thus energizing the coil of 

the relay. The relay turns ON or OFF the connected equipment.
1. An  air  button  with  ruptured  seal  or  bellows  inside,  will  not  produce  sufficient  air  pressure  to  operate  the 

  momentary air switch and could lead to total break down.
2. Water in air hose will damage the pulse switch and it is caused by a faulty air button (see note 1 above) or 

  condensation. In either case, it must be drained and the cause found and corrected. To reduce condensa-

  tion,  protect  the  air  hose  from  exposure  to  direct  sun,  ice  or  frequent  temperature  fluctuations.
3. A  defective  relay  is  either  due  to  contact  or  coil  failure.  Contact  failure  is  caused  by  over-load  or  cross-

  wiring and coil failure is caused by 240 volt connected across the 120 volt coil or permanently applied 120 

  volt. (The relay is designed for intermittent duty only). Permanently applied 120 volt could be the result of 

  water in the air hose (see note 2 above) or a spa cover placed over (and depressing) the air button. In any 

  case, the cause must be found, corrected and the relay replaced.

 

 

3

TIMER

TIME

CLOCK

MOTOR