Power Failure Path Lighting

Remove existing receptacle from the wall box (if necessary).
Strip building wires to 7/16”.
Connect the BLACK wire to the line building wire, us-
ing a twist connector (provided).
Connect the WHITE wire to the neutral building wire, 
using a twist connector (provided).
NOTE: Insert wires straight into twist connector, then 
twist clockwise. Make sure all twist connectors are tight. 
Secure each twist connector with electrical tape. Make 
sure no bare wire shows below the twist connector.
Connect the ground wire from the box to the GREEN 
screw on the EL200 unit. If there is no ground wire, 
ground the EL200 unit to the box. If using a plastic box, 
connect to ground as supplied.
Tuck wires into wall box leaving room for the EL200 
unit.
Using screws provided, mount the EL200 unit to the wall box, 
then install wall plate. 
Turn power back on at the service panel.

1.
2.
3.

4.

5.

6.

7.

8.

Voltage — 120 Volts, 60 Hz
Colors — White, Ivory, Light Almond
Consumption — 17.0 watts max.
Receptacle Amperage — 15 Amps General Purpose
Battery — Single rechargeable 2/3A NiMH provides 1.5 hours life 
in use.
Light Source — 3 high-output white LEDs
Temperature Operating Range — 32°F to 104°F / 0°C to 40°C
Storage Range — -31°F to 158°F / -35°C to 70°C
Environmental — 10% to 95% non-condensing relative humidity
For Indoor Use Only









Installation and User Instructions

MODEL EL200 Series

Turn off power at the service panel by REMOVING FUSE or 
TURNING THE CIRCUIT BREAKER OFF.
Test to VERIFY that the power is off.

1.

2.

Before You Begin

Installation Instructions

Specifications

The EL200 Series unit can be operated in five different modes. 
NOTE: After installation, the battery reaches maximum charge in 
about one week.

Night Light ON — Press the lens once when the night light is 
OFF and the night light will come ON at 25% of full brightness. 
In this mode the night light is powered by the building current.
Night Light OFF — Press the lens once when the night light is 
ON and the night light will power OFF. 
Power Failure Light ON — When building current is discon-
nected (e.g., during a power failure), the power failure light will 
automatically come ON at 100% of full brightness and remain lit 
until the battery is discharged (1.5 hours at a full charge). NOTE: 
As the battery runs out of power, the unit will begin to flash and 
will continue to do so until all power is drained from the battery 
or power is restored.
Power Failure Light OFF — When the power failure light is ON 
(and the unit is operating on battery power), press and hold the 
lens for 5 or more seconds to manually turn it OFF. NOTE: You 
can press and hold the lens again for 5 or more seconds to turn 
the light back ON.
Battery Test — After battery has had a minimum of 1 week to 
charge, press and hold the lens for 5 seconds to switch the unit 
from building current to battery power which turns ON the light 
at the 100% brightness level. If the light doesn’t come on, the 
battery is dead or damaged. Releasing the lens will switch the 
unit back into normal operation.

How To Operate the EL200 Series

Electrical shock hazard. To avoid fire, shock, or death, turn off power 
at circuit breaker and test that power is off before wiring.
Follow local electrical codes during installation.
Connect to copper conductors only.
Connect to Class 1 wiring only.



     WARNING

No user-serviceable parts.

NOTICE