background image

2 / 3 

 

P/N 1053528-EN 

• REV 

• ISS 

16JUL18 

Figure 3: Marking the mounting holes 

 

1. 

Middle holes are for 

extra support.

 

 

 

2. 

Following all local codes, drill and prepare the mounting 

holes.  

3. 

Orient the mounting plate such that the socket is up and 

the junction box is down (Figure

 1 on page 1

).

 

4. 

Securely fasten the mounting plate to the mounting 

surface with the appropriate fasteners. Before installing 

anchors into the middle holes, place the 

safety U bracket 

on top of the mounting socket, aligning the holes in the 

safety U bracket with the middle holes on the mounting 

plate. 

5. 

If needed, seal all mounting holes so that no moisture can 

leak into the mounting surface.

 

Installing the swing arm 

See Figure

 4 

below

 

and do the following:

 

1. 

Slide the swing arm down into the mounting socket of the 

mounting plate.

 

2. 

Position the arm such

 

that the collar is accessible from the 

rooftop for mounting the housing.

 

3. 

Temporarily tighten the pivot locking screws on the arm, 

while you continue installing the mount.

 

Figure 4: Installing the swing arm 

 

1. 

Pivot locking screws

 

 

 

Installing the interconnect cables and 

junction box 

1.  Feed the interconnect 

cables through the junction box, the 

chase nipple of the junction box, and up through the swing 

arm (

Figure

 5 on page 3

).

 

 

Pull enough extra cable to make connections. You 

can always cut off unneeded length later.

 

 

Do not terminate the cables yet. Otherwise, they will 

not fit through the dust seal of the housing.

 

2. 

Ensure that the parallel sides of the chase nipple are 

aligned with the front and back of the top of the junction 

box (Figure

 5 on page 3

). Otherwise, the chase nipple 

may catch on the lower lip of the mounting socket.

 

Reviews: