P/N 1073093-EN
• REV
A
• ISS 30SEP15
3 / 5
Screw 5 pcs
:
Drywall anchor
(
7.5 x 24.5
mm)
M4 screw
(4 x 25
mm)
Screw 3 x 8 mm (2 pcs):
Screw 4 x 10 mm (3 pcs):
Figure 4: Wedge camera attached to a 2 gang box
Installation
To mount two wedge cameras on a dual view mount:
1.
Attach the TVW
-
DVM dual view mount to an installed
pendant mount tube. An adapter is included in the kit that,
if required, can be used to match
-
up with the threading
(G1 male or G1 female) of the pendant mount tube
.
2.
Loosen the screws with
the
tamper
-
resistant hex wrench
(supplied) to remove the camera cover.
3.
Pull the cables through the bracket tube and to both back
boxes, conect the cables to cameras and place the
connecters and cables into the back boxes.
4
.
Mount the two camera
s on both sides
of the TVW
-
DVM
dual view mount
.
5.
Re
-
attach the camera covers to the cameras.
To mount the wedge camera on an outdoor angled back
box:
1.
Drill the holes for the mounting hardware i
n the
mounting
surface
using
the supplied drill template.
2.
Detach the TVW
-
2G
-
AD
adaptor plate
from the back box.
3.
Mount the
TVW
-
2G
-
AD
adaptor plate
to the mounting
surface
using the supplied hardware.