Chapter 7: Playback functionality
TruVision DVR 15HD User Manual
45
2. Select the type of event to search for from the right-hand side of the window: Alarm
Input, Motion, or VCA Alarm.
If you select
VCA Alarm
, select the type of VCA alarm under
Minor Type
. Also
select the desired cameras to search.
If you select
Alarm Input
, select the desired alarm inputs from the list displayed.
If you select
Motion
, select the desired cameras to search.
Note
: Motion detection must be enabled in order to use this function. See “Motion
detection” on page 72 for information.
3. Select the start and end dates and times for the event search.
4. Click Search to searching for the desired events.
The results are listed on the right side of the window. Each individual recorded event
is listed. They are collectively not shown on the playback toolbar.
5. Select the desired pre and post-event times (between 5 and 600 seconds). Default
time is 30 seconds.
Note
: These pre and post-event times are independent to the times set for camera
recordings under Camera Setup > Camera Recordings Settings. If you are only
recording events, the default pre and post-event times are determined by the values
set up under Camera Setup > Camera Recordings Settings. Default is 5 seconds.
6. Click the desired camera recording to play back. Its time bar also appears on the
playback toolbar.
7. Click
Exit
to stop the play back and return to the previous window. You can do
another search selection.
8. Click to exit playback and return to live view.