background image

ACURT2 and ACURT4

Information Packet

4

DIP Switch SW3 Settings

Note:  

See page 11 for switch location

Switch 

SW3

Description

S1

OFF

 = LAN Disabled 

1

 

ON

 = LAN Enabled

1.

Indicates the default setting

S2

OFF

 = Do Not Allow LAN IP Parameters to be Updated 

1

,

ON

 = Allow LAN IP Parameters to be Updated

S3

OFF

 = Do Not Use LAN default IP Parameters 

1

ON

 = Set IP Address To 192.168.0.132

S4

OFF

 = Triple DES Disabled 

1

,

ON

 = Triple DES Enabled

S5

Undefined, Leave 

OFF

 

1

S6

OFF

 = Wiegand or Proximity cards 

1

 

ON

 = Magnetic Stripe Cards

S7

OFF

 = RAM Not Battery Backed Up 

ON

 = RAM Battery Backed Up 

1

S8

OFF

 = Watch Dog Timer Enabled 

1

ON

 = Disable Watch Dog Timer

Current Switch Setting

SW 3

1

2

3

4

5

6

7

8

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

ON

ON

ON

ON

ON

ON

ON

ON

Summary of Contents for Topaz ACURT2

Page 1: ...Dial Up Phone Number IP Address IP Router Address This information packet is for reference only See the TOPAZ Hardware Installation Guide for complete instructions UTC Fire Security 9 Farm Springs Ro...

Page 2: ...s and companies Any similarity to names and addresses of actual businesses or persons is entirely coincidental Trademarks and patents Trade names used in this document may be trademarks or registered...

Page 3: ...onnection 13 Terminal Block TB3 connection 14 Terminal Block TB4 connection 14 Terminal Block TB5 connection 15 Terminal Block TB6 connection 16 Terminal Block TB7 connection 16 Terminal Block TB8 con...

Page 4: ...ACURT2 and ACURT4 Information Packet iv...

Page 5: ...ition Terminated OFF Position Not Terminated S1 Host TX Line Terminated S2 Host RX Line Terminated S3 Expansion Module Port TX Line Terminated S4 Expansion Module Port RX Line Terminated Current Switc...

Page 6: ...ON OFF 57600 ON ON OFF 1200 OFF OFF ON 115200 ON OFF ON 2400 OFF ON ON 4800 ON1 1 Indicates default setting ON1 ON1 9600 S4 OFF1 Host Encryption disabled ON Host Encryption enabled S5 ON Dial up Host...

Page 7: ...3 Current Switch Setting1 1 Circle the current settings SW 2 1 2 3 4 5 6 7 8 OFF OFF OFF OFF OFF OFF OFF OFF ON ON ON ON ON ON ON ON...

Page 8: ...Parameters to be Updated S3 OFF Do Not Use LAN default IP Parameters 1 ON Set IP Address To 192 168 0 132 S4 OFF Triple DES Disabled 1 ON Triple DES Enabled S5 Undefined Leave OFF 1 S6 OFF Wiegand or...

Page 9: ...evice1 Off Position Not Terminated Zone In Use 1 All termination is 1 kohm Current Setting S1 Terminates Zone Input Reader 0 Zone 0 S2 Terminates Zone Input Reader 0 Zone 1 2 2 If the Exit Push Button...

Page 10: ...ermination is 1 kohm Current Setting S1 Terminates Zone Input Reader 2 Zone 0 S2 Terminates Zone Input Reader 2 Zone 1 2 2 If the Exit Push Button is not connected another 1 kohm resistor must be inst...

Page 11: ...n DIP switch SW2 to OFF 4 Set the polling address of the Rotary Switch SW4 to F 5 Apply power to the ACURT2 or ACURT4 6 LEDs 1 4 will blink together indicating that the operation is complete 7 Turn po...

Page 12: ...the four LEDs The table describes the sequence The LEDs on the printed circuit board will light as follows Note See page 11 for LED location LED Description LED 1 ON indicating power up LED 2 ON when...

Page 13: ...occurs LINK ON When cable is connected REV ON When cable is reversed RS 232 AND RS 485 Communication Status LEDs LED Description TX D1 Flashing when transmitting RS 232 or RS 485 green LED RX D2 Flash...

Page 14: ...eplace RAM back up battery every five years using 3 AAA Nickel Cadmium Replace the clock calendar battery every five years with 1 CR2023 Lithium or the equivalent Replace the UPS batteries as needed A...

Page 15: ...E 1 LED READER 2 ZONE 0 LED READER 3 ZONE 0 LED READER 3 ZONE 1 LED READER 3 ZONE 2 LED BT2 READER 2 DOOR STRIKE RELAY LED READER 0 DOOR STRIKE RELAY LED READER 1 DOOR STRIKE RELAY LED READER 3 DOOR S...

Page 16: ...ip Description Connected to Cable Color 1 SIG GND Host Port Signal Ground 2 TXD Host Port RS 232 Transmit Data 3 RXD Host Port RS 232 Receive Data 4 RTS Host Port RS 232 RTS 5 CTS Host Port RS 232 CTS...

Page 17: ...2 VDC 12 VDC Output 1 1 1 0 A maximum combined for all readers 2 5 VDC 5 VDC Output 2 2 0 80 A maximum combined for all readers 3 0 V 0 V 4 DATA 0 Reader 0 Data 0 green input 5 DATA 1 Reader 0 Data 1...

Page 18: ...r 0 Zone 1 input request to exit 4 Z1 Reader 0 Zone 1 input request to exit 5 Z2 Reader 0 Zone 2 input auxiliary input 6 Z2 Reader 0 Zone 2 input auxiliary input READER 0 Pin No Term Description Conne...

Page 19: ...ted to Cable Color 1 12 VDC 12 VDC Output 1 1 1 0 A maximum combined for all readers 2 5 VDC 5 VDC Output 2 2 0 8 A maximum combined for all readers 3 0 V 0 V 4 DATA 0 Reader 1 Data 0 green input 5 DA...

Page 20: ...1 Zone 1 input request to exit 4 Z1 Reader 1 Zone 1 input request to exit 5 Z2 Reader 1 Zone 2 input auxiliary input 6 Z2 Reader 1 Zone 2 input auxiliary input READER 1 Pin No Term Description Connec...

Page 21: ...ion Connected to Cable Color 1 SIG GND Host Port Signal Ground 2 TX Expansion Module Port RS 485 Transmit Data 3 TX Expansion Module Port RS 485 Transmit Data 4 RX Expansion Module Port RS 485 Receive...

Page 22: ...Aux Relay Normally Closed Contact 1 1 Contacts are rated for 30 VDC 2 0 A maximum Do not switch voltages higher than 30 volts 2 C Reader 2 Aux Relay Common Contact 1 3 NO Reader 2 Aux Relay Normally...

Page 23: ...VAC 24 VAC Input 2 24 VAC 24 VAC Input 3 0 V 0 V 4 0 V 0 V 5 24VDC BATTERY Lead or 27 5VDC power supply 6 24VDC BATTERY Lead or 0 volts from power supply Pin No Term Description Connected to Cable Col...

Page 24: ...nected to Cable Color 1 12 VDC 12 VDC Output 1 1 1 0 A maximum combined for all readers 2 5 VDC 5 VDC Output 2 2 0 80 A maximum combined for all readers 3 0 V 0 V 4 DATA 0 Reader 2 Data 0 green input...

Page 25: ...1 input request to exit 4 Z1 Reader 2 Zone 1 input request to exit 5 Z2 Reader 2 Zone 2 input auxiliary input 6 Z2 Reader 2 Zone 2 input auxiliary input READER 2 Pin No Term Description Connected to...

Page 26: ...lor 1 12 VDC 12 VDC Output 1 1 1 0 A maximum combined for all readers 2 5 VDC 5 VDC Output 2 2 0 8 A maximum combined for all readers 3 0 V 0 V 4 DATA 0 Reader 3 Data 0 green input 5 DATA 1 Reader 3 D...

Page 27: ...3 Z1 Reader 3 Zone 1 input request to exit 4 Z1 Reader 3 Zone 1 input request to exit 5 Z2 Reader 3 Zone 2 input auxiliary input 6 Z2 Reader 3 Zone 2 input auxiliary input READER 3 Pin No Term Descrip...

Page 28: ...ader 2 Aux Relay Normally Closed Contact 1 1 Contacts are rated for 30 VDC 2 0 A maximum Do not switch voltages higher than 30 Volts 2 C Reader 2 Aux Relay Common Contact 3 NO Reader 2 Aux Relay Norma...

Reviews: