background image

2

SuperBus® 2000 Commercial RF Transceiver Module

Installation

For power wiring refer to Table 1 in the Advent Panel 
Installation Instructions for maximum wire length rec-
ommendations. If the maximum recommended wire 
length from Table 1 must be exceeded, a remote DC 
power supply will be required. When using a remote 
power supply, the power and ground connections of 
panel and remote supplies must remain isolated and the 
power supply output must be isolated from earth 
ground. Do not connect panel and remote power sup-
plies together.

R Avoid areas with excessive metal or electrical wiring, 

including furnace and utility rooms. If unavoidable, 
mount on or near metal with the antennas extending 
above the metallic surfaces, as shown in Figure 2. 

Figure 2.  Mounting on or Near Metal 

Installation

The transceiver can be mounted on any interior wall (pro-
tected from the elements).

To prepare for mounting (all case versions):

1/" 

You must be free of static electricity before 
handling circuit boards. Wear a grounding strap 
or touch a grounded bare metal surface to dis-
charge static electricity.

 œÌi

If possible, temporarily mount, connect, and test the 
RF transceiver at the desired location to evaluate per-
formance in the particular environment.

R Disconnect the panel backup battery and turn off power 

to the AC power transformer.

Installing the Plastic Case Module

To mount the plastic case transceiver:

Figure 3. Removing the Plastic Cover

1.

Remove the transceiver cover and the circuit card and 
set them aside (see Figure 3).

2.

Hold the base against the mounting surface and mark 
the four mounting holes (see Figure 4). Remember to 
leave at least 10 inches

 

above the base for the anten-

nas.

3.

Drill holes and insert appropriate anchors.

4.

Secure the back plate to the wall with panhead screws.

5.

Snap the circuit card back into the backplate. 

Figure 4. Mounting Holes

To install the antennas:

1.

Loosen the inside terminals of the left and right 
antenna terminal blocks (see Figure 1).

2.

Insert an antenna into each inside terminal.

3.

Tighten the antenna terminal screws.

Installing the Metal Case Module

To mount the metal case transceiver:

1.

Remove the metal case cover and transceiver circuit 
card, and set them aside.

2.

Hold the case against the mounting surface and mark 
the four [larger] mounting holes. Remember to leave at 
least 10 inches

 

above the case for the antennas.

3.

Drill the mounting holes in the wall and insert the 
appropriate anchors.

4.

Remove case wiring knockouts as necessary.

5.

Secure the case to the wall with panhead screws.

6.

Snap the included 1/4 inch plastic spacers into the back 
of the circuit board as shown in Figure 5. 

7.

Snap the circuit board into the case (see Figure 6).

METAL

METAL

COVER SCREWS (2)

BACKPLATE

CIRCUIT CARD

COVER

CARD LATCHES (2)

MOUNTING HOLES (4)

Summary of Contents for SuperBus 2000

Page 1: ... included R Two antenna grounding screws included in metal case kit R 1 4 inch plastic spacers included in metal case kit R Small standard and Phillips screwdrivers R 4 conductor 18 gauge or larger stranded hookup wire is recommended Installation Guidelines Observe the following guidelines when installing the trans ceiver R Advent systems can accommodate up to 250 sensors zones See specific panel ...

Page 2: ...off power to the AC power transformer Installing the Plastic Case Module To mount the plastic case transceiver Figure 3 Removing the Plastic Cover 1 Remove the transceiver cover and the circuit card and set them aside see Figure 3 2 Hold the base against the mounting surface and mark the four mounting holes see Figure 4 Remember to leave at least 10 inches above the base for the anten nas 3 Drill ...

Page 3: ...describes how to wire the transceiver to Advent panels Advent Panel Wiring To wire the RF Transceiver to Advent panels Wire the transceiver to the panel s SuperBus wiring harness wires as shown in Figure 8 Figure 8 Wiring to Advent Panels Module Hardwire Zone Wiring This section describes how to wire the transceiver hardwire zone input terminals To wire the RF transceiver zone input Connect the mo...

Page 4: ...backup battery and the AC power transformer Alphanumeric touchpad displays should come on 3 Press 8 to select System Menu 4 Press 0 to select Enter Program Mode 5 Enter the install code defaults to 0123 6 Enter Item Number 48001 to add SuperBus devices All installed devices are automatically added learned into panel memory when Devices Added is indicated 7 Press twice to return to the normal mode ...

Page 5: ...on densing Table 2 Wireless Device Compatibility Part No Description 60 348 Learn Mode Hand Held Wireless Touchpad 60 362 Learn Mode Door Window Sensor 60 409 Learn Mode Recessed Door Window Sensor 60 452 Learn Mode Pendant Panic Sensor 60 453 Wall Mount Wireless Touchpad 60 457 Dual Button Panic Sensor 60 458 Single Button Panic Sensor 60 459 Sound Sensor 60 460 Rate of Rise Heat Sensor 60 461 Le...

Page 6: ... generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case users will be required to correct the interference at their own expense FCC Part 15 Class B This equipment has bee...