4.  Connect the four-conductor’s green and red wires to the 

protector block’s TIP (+) and RING (-) posts (see 

in 

Figure 6 below). 

Figure 6: Connecting an RJ-31X jack to a home phone line 

BRN

GRY

GRN

RED

DE

R

ETI

H

W

R

O(

)

W

OL

LE

Y

BLAC

K

GREEN

RED

RING

(-)

GREEN

RED

TIP

(+)

RJ-31X

JACK

GREEN

BLACK

WHITE (OR YELLOW)

A

B

C

D

Telco Protector

Block

RJ-31X

Phone Line

Wire Run

Home

Phone

Lines

 

Wiring Connections for Concord Panels  

Wiring a Concord system requires you to wire for power, bus, 

speaker, and phone lines. Refer to the figures shown below for 

wiring designated partitions. 

Caution: 

To prevent damage to the panel, or module, remove 

the panel’s AC power transformer and disconnect the backup 

battery prior to wiring. 

Wiring - Power and Bus 

All partitions 

Figure 7: Wiring the PIV module to panel power and Bus terminals 

Panel Terminals

Phone Interface/Voice

Module Terminal Strip 1

Phone Interface/Voice

Module Terminal Strip 2

 

Wiring - phone line 

Note

: All partitions must be wired to separate phone lines. 

Partition 1 

Figure 8: Wiring the PIV module to a phone line (partition 1) 

Phone Interface/Voice

Module Terminal Strip 1

Phone Interface/Voice

Module Terminal Strip 2

DB-8 Cord

Plug

 

All other partitions 

Figure 9: Wiring the PIV module to a phone line (all other 
partitions) 

Phone Interface/Voice

Module Terminal Strip 2

DB-8 Cord

Plug

 

Wiring - speakers 

Note

: Do not connect speakers to the panel if terminals 7 and 

8 are connected to PIV terminals 8 and 9 ( see Figure 10 on 

page 5). 

4  

SuperBus 2000 Phone Interface/Voice Module Installation Instructions 

Summary of Contents for SuperBus 2000 PIV

Page 1: ...ically learned by the panel Potential identical unit number conflicts and the need to manually set DIP switches are eliminated Older SuperBus panels can communicate with the PIV module by manually setting the module s DIP switches SuperBus 2000 Panels Concord v2 0 later Concord 4 Concord Express v4 SuperBus Panels Concord v1 0 1 6 Features The PIV module includes the following features User adjust...

Page 2: ...d Four conductor 22 gauge or larger stranded wire RJ 31X Phone Jack not included DB 8 Cord included with Concord cabinet Support standoffs included with Concord cabinet Installation When installing the PIV module mount the module inside a panel cabinet or on a wall Caution To prevent damage to the panel or module remove the panel s AC power transformer and disconnect the backup battery before inst...

Page 3: ...ollowing guidelines prior to installing an RJ 31X phone jack Do not mount an RJ 31X jack CA 38A in Canada more than five feet away from the panel Connect the panel to a standard analog phone line Ensure the analog line provides 48V DC and can increase from 89V to 130V DC while the line is in use Note Concord panels cannot be used on a digital or PBX phone line These line types are designed only fo...

Page 4: ...ct the backup battery prior to wiring Wiring Power and Bus All partitions Figure 7 Wiring the PIV module to panel power and Bus terminals Panel Terminals Phone Interface Voice Module Terminal Strip 1 Phone Interface Voice Module Terminal Strip 2 Wiring phone line Note All partitions must be wired to separate phone lines Partition 1 Figure 8 Wiring the PIV module to a phone line partition 1 Phone I...

Page 5: ...ned to Partition 2 Note Because unit numbers for Concord RF receivers are factory set to 15 do not use this unit number setting Setting DIP Switches On the module locate the DIP switches see Figure 1 on page 1 Next set the desired unit number from 0 to 15 see Figure 12 below before you turn the power on Note DIP switches 1 4 are not used and must be set to OFF Figure 12 Unit number DIP switch sett...

Page 6: ...f the LED remains off replace the module The status LED remains lit but does not flash 1 Verify the panel recognizes the module see panel Installation Instructions 2 Check for proper wiring connections 3 If the LED fails to flash replace the module The module has a random inconsistent behavior 1 Check for proper wiring connections 2 Verify the panel recognizes the module see panel Installation Ins...

Page 7: ... to separate outlets on different branch circuits Consult the dealer or an experienced radio TV technician for help FCC Part 68 This equipment complies with part 68 of the FCC Rules Located on this equipment is a label that contains among other information the FCC registration number and the ringer equivalence number REN for this equipment If requested this information must be provided to the tele...

Reviews: