Simon XT Installation Manual 

 

 

 

 

P/N 466-2265 

• REV G • OCT12 

Summary of Contents for Simon XT

Page 1: ...Simon XT Installation Manual P N 466 2265 REV G OCT12 ...

Page 2: ...g this Software This agreement provides a license from UTC FIRE SECURITY to use the Software It also contains warranty information disclaimers and liability limitations Installing and or using the Software confirms Your agreement to be bound by these terms and conditions If You do not agree with these terms and conditions do not install or use the Software or if already installed immediately cease...

Page 3: ...ise and this Agreement shall automatically terminate in the event of such a transfer or distribution use the Software over a computer network sell rent lease or sublicense the Software copy or modify the Licensed Product for any purpose including for backup purposes Term This Agreement is effective until terminated You may terminate this Agreement by uninstalling all components of the Software fro...

Page 4: ...r expressed or implied including but not limited to implied warranties of merchantability or fitness for a particular purpose and except as expressly provided above You assume the entire risk as to the quality and performance of the licensed product Limitation of liability UTC FIRE SECURITY s sole obligation or liability under this agreement is the repair or replacement of nonconforming software a...

Page 5: ...ontact your local supplier or visit us online at http www utcfireandsecurity com FCC compliance This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential environment This equipment generate...

Page 6: ...to a properly installed RJ31X jack that is electrically in series and ahead of all other equipment attached to the same telephone line If you have any questions concerning these instructions consult your local telephone company or a qualified installer about installing an RJ31X jack and alarm dialing equipment for you If this equipment causes harm to the telephone network the telephone company may...

Page 7: ...nada listed installations 20 California state fire marshal listed installations 20 Opening panel cover and chassis 20 Mounting the panel 21 Connecting hardwired devices 22 Wiring a phone line to the panel 25 Wiring the power transformer 27 Installing X10 modules 29 Programming 31 Programming overview 31 Menu navigation 33 Set clock 34 Set date 34 Revision 35 Contrast 35 System programming 36 Phone...

Page 8: ...etting memory to factory defaults 54 Testing 56 Control panel 56 Sensors 57 Phone communication 59 Offsite phone operation 60 Central station communication 60 Two way voice operation 61 Voice event notification 62 X10 operation 62 Troubleshooting 64 Specifications 65 Sensor names 66 ...

Page 9: ...ree types of components Self contained control panel Devices that report to the panel Devices that respond to commands from the panel Note The keyfob and X10 modules have not been investigated by UL Figure 1 Simon XT system Note The universal lamp and appliance modules require a special transformer The self contained panel provides the main processing unit for all system functions It receives and ...

Page 10: ...ways are typical locations for indoor motion sensors For installations with pets use the SAW Pet Immune PIR 60 807 Outdoor motion sensor 60 639 Use outdoor motion sensors to detect motion in a protected outdoor area Detected motion in this protected area can sound chimes X10 module When the panel is powered using the line carrier power transformer the system can work with any of the following modu...

Page 11: ...an use key fobs to turn all system controlled lights on and off ELM encrypted learn mode key fob 60 832 The ELM 2 button key fob is an alkaline battery powered wireless touchpad that allows you to arm and disarm the system and activate a police or auxiliary alarm Random encrypted signal transmissions provide high security to help prevent signal copying Remote handheld touchpad 60 671 The remote ha...

Page 12: ...nel to communicate with the central monitoring station and or remote phone Inspect the package and contents for visible damage If any components are damaged or missing do not use the unit contact the supplier immediately If you need to return the unit you must ship it in the original box ...

Page 13: ...n is to decide what areas or items to protect which lights or appliances to operate and the best location for the panel touchpad sensors and sirens Metal objects mirrors and metallic wallpaper can block signals sent by the wireless sensors Make sure there are no metal objects in the way when installing the system Use Table 3 below and Table 4 on page 8 to determine the appropriate sensor type for ...

Page 14: ...e emergency button Intrusion I N N 1234 02 Fixed panic 24 hour silent fixed emergency button Status light will not blink Silent I N Y 01234 03 Portable panic 24 hour silent portable emergency buttons Status light will not blink Silent I N N 01234 04 Fixed auxiliary 24 hour auxiliary sensor Emergency I N Y 01234 05 Fixed auxiliary 24 hour emergency button Siren shut off confirms CS report Emergency...

Page 15: ...rm zone protecting anything that opens and closes No report Intrusion I Y Y 1234 22 Local delayed interior Same as group 21 plus activation initiates a delay before going into alarm No report Intrusion S Y Y 1234 23 Local instant auxiliary 24 hour local alarm zone protecting anything that opens and closes No report Emergency I Y Y 01234 24 Local instant auxiliary 24 hour local alarm zone protectin...

Page 16: ... X10 modules turn either on or off when a door is opened b Silent I N Y 01234 38 Auxiliary Water sensor Trouble beeps I Y Y 01234 39 Local instant interior 24 hour local alarm zone protecting anything that opens and closes No report Intrusion I Y Y 1234 40 Local special chime Three beeps I Y Y 01234 Table 5 Sensor assignment locations Sensor Device Sensor group Sensor name location Notes 01 02 03 ...

Page 17: ... must be tripped within two minutes of each other to report an alarm to the central station Figure 2 on page 12 shows the path of a person walking from the kitchen to the living room When the person is detected walking through the kitchen the motion sensor in the kitchen is tripped sounding a local alarm If motion is detected by the living room motion sensor within two minutes an alarm report will...

Page 18: ...amming privilege are also listed Table 6 System programming menu options Function Default Delete Range Access code Installer settings Access codes menu Dealer code 654321 54321 4321 or 321 None 3 to 6 digits D Installer code 654321 54321 4321 or 321 None 3 to 6 digits D I Master code 123456 12345 1234 or 123 None 3 to 6 digits D I M User code 1 None None 3 to 6 digits D I M User code 2 None None 3...

Page 19: ...m low battery Off Off On Off D I Quick exit Off Off On Off D I Downloader enable On Off On Off D I M Supervisory protest Off Off On Off D I Phone menu Phone 1 None None 26 digits D Phone 2 None None 26 digits D Phone 3 None None 26 digits D I Phone 4 None None 26 digits D I M Downloader None None 26 digits D I Phone options menu Manual phone test On Off On Off D I Fail to communicate On Off On Off...

Page 20: ... I Swinger shutdown On Off On Off D I Programming report Off Off On Off D I Fire alarm verification Off Off On Off D I Report communication modes Phone 1 report mode Off Off All SIA All CID Alarms SIA Alarms CID Nonalarm SIA Nonalarm CID Backup SIA Backup CID Voice dialer or Off D Phone 2 report mode Off Off D Phone 3 report mode Off Off D I Phone 4 report mode Off Off D I Timers menu Latchkey tim...

Page 21: ...ad options menu Key fob no delay Off Off On Off D I Panic alarms On Off On Off D I Remote touchpad arming Off Off On Off D I System options menu RF jam detect Off Off On Off D I Demo mode Off Off On Off D I HW1 function 1 Off 1 2 3 4 5 or Off D 24 hour clock Off Off On Off D I Siren options menu Panel piezo beeps On Off On Off D I M Panel voice On Off On Off D I M Panel piezo alarms On Off On Off ...

Page 22: ... 6 1 to 32 D I Vox mic gain 24 24 1 to 64 D I Vox mic gain range 64 64 1 to 64 D I Manual mic gain 64 64 1 to 64 D I System test menu Sensor test D I M Communication test D I M System download D I M Emergency planning Use these guidelines when drawing an emergency floor plan for the homeowner Show all building levels Show exits from each room We recommend two exits per room Show the locations of a...

Page 23: ...UTC Fire Security Part 22 155 Hardwired siren 13 374 Household burglary alarm system unit UL 1023 basic system plus the following Hardwired magnetic contact 13 068 or 13 071 or wireless learn mode door window sensor 60 670 Panel piezo beeps set to on Entry delay set to 45 seconds or less Exit delay set to 60 seconds or less RF time out set to 24 hours Control panel alarms turned on Autoarm set to ...

Page 24: ...cate set to on Entry delay plus the dialer delay must not exceed 60 seconds SIA system requirements SIA system requirements are the same as those described for a UL listed basic system on page 1 plus If multiple annunciation is required use hardwired siren part no 13 046 Note UL requirements take priority over SIA requirements Entry delay must not exceed 60 seconds SIA setting requirements Table 7...

Page 25: ...tors disabled Remote arming exit time and progress annunciation All annunciators enabled Abort annunciation Enabled Cancel report annunciation Enabled Recent closing Enabled two minute window Exit error Enabled Restoration of power Panel resumes operation in same arming state and disregards alarm signals from sensors for the first 60 seconds after power restoration Cancel alarm Enter code only Cen...

Page 26: ...ut set to six minutes or more Residential fire warning system control unit ULC S545 M89 Basic system as described for UL 985 listed installations plus Wireless smoke sensor 60 848 95 learned into sensor group 26 Siren timeout set to six minutes or more For 24 hour backup the total current draw for all connected devices is limited to 250 mA during normal standby conditions using a 1 2 AH battery Ca...

Page 27: ...en choosing the AC outlet location for the AC power transformer make sure the outlet is not controlled by a switch or that it is not part of a ground fault circuit interrupt GFCI 3 Hold the panel against the wall and mark the mounting hole locations with a pencil 4 Mount the back piece to the wall through the two horizontally centered mounting holes near the top and bottom using the supplied mount...

Page 28: ...ires through openings in the back piece to be ready to attach them to the screw terminals or the phone connectors 7 Install all screws and tighten gently Connecting hardwired devices The panel has seven screw terminals and two telephone connections Figure 5 on page 23 The screw terminals connect AC power sirens and or hardwired detectors Program sensors and devices before you install them Follow t...

Page 29: ...oad of 250 mA With Hardwired Siren Supervision turned on sirens connected to HW1 I O are supervised and require a 4 7 kohm resistor in the circuit If this terminal is not used turn Hardwired Siren Supervision off LD105 hardwired interior siren Interior sirens must always be wired with a resistor in the circuit For circuit supervision which allows the panel to detect if the siren wire is cut open H...

Page 30: ...hardwired siren and or HW2 in Note Connect only normally closed NC reed switches to HW1 I O and or HW2 in Other types of hardwired detectors should not be used The total resistance of the wire loop must not exceed 3 ohms This allows you to use up to 200 ft 61 m of two conductor 22 gauge stranded wire Connect hardwired reed switches to the panel using a 47 kohm resistor not a 4 7 kohm resistor as s...

Page 31: ...ner Other devices in use at the same time the panel is using the line can prevent reports from going through Full line seizure Full line seizure allows the panel to take over seize the phone line even if another device on the line is in use This method requires that the panel be wired before all other phones answering machines computers or other devices on the phone line You may need to verify lin...

Page 32: ... Telco block D TIP and red to RING posts 5 Connect the phone cord E included with the panel to the RJ31X B and the panel LINE jack Figure 8 Full line seizure wiring with RJ 31X Full line seizure wiring with one premises phone If a single phone is all that exists on the premises full line seizure can be accomplished without an RJ31X Figure 8 above 1 Disconnect the phone from the premises phone jack...

Page 33: ... to another phone jack full line seizure no longer exists Inform them to contact you if they want to add a phone or other device so that you can rewire for full line seizure by adding an RJ31X Figure 9 Full line seizure wiring with single landline phone Wiring the power transformer Connect the power transformer to the panel AC terminals as shown in Figure 10 on page 28 ...

Page 34: ...nstall the backup battery 6 VDC 1 2 Ah do the following 1 Connect the lug end of the red battery lead to the red battery tab 2 Connect the lug end of the black battery lead to the black battery tab 3 Align the red battery terminal with the right end of the terminal strip The logo and specification information should be readable 4 Insert the front end of the battery under the forward battery compar...

Page 35: ... receive a serious shock if a metal outlet cover drops down onto the prongs of the plug 2 Plug the transformer into the lower receptacle of the outlet so that the hole in the transformer tab lines up with the outlet cover screw hole 3 Insert the cover plate screw through the transformer tab and the outlet cover plate Tighten the screw Installing X10 modules To install lamp and appliance modules do...

Page 36: ...niversal modules do the following 1 Set the unit code dial to a unit number different from all other X10 modules between 1 and 8 2 Set the housecode for the installation 3 Set the module switches to momentary and relay only 4 Connect the module terminals to the desired device terminals 5 Plug the universal module into a wall outlet ...

Page 37: ...ng the system time Table 9 below explains the panel keys and features shown in Figure 12 below Figure 12 Simon XT self contained panel Table 9 Simon XT panel keys and features Control Description Piezo siren The piezo siren makes alarm beeps and status beeps Fire and intrusion alarm beeps are always played at high volume while the volume of status beeps is programmable LCD display The LCD module h...

Page 38: ...roll down Press to scroll through lists of similar items OK Press to select a particular menu item or commit to memory a menu item that has just been programmed Numeric keypad Twelve key telephone type keypad 0 through 9 for entering access codes or other numerical data light bulb Lights on Contact UTC Fire Security for required equipment information dark light bulb Lights off Contact UTC Fire Sec...

Page 39: ...When accessing the System programming or System tests menu the panel prompts you to enter an access code To continue enter the dealer code or installer code then press Enter To program an option first navigate to that option until it is displayed then press Enter The option value will start flashing indicating that it is ready to be changed Use the scroll keys or enter a numerical value to change ...

Page 40: ... hour format To reset the clock 1 Scroll until the display shows Set Clock and then press OK The display shows Enter Code 2 Enter your code with the numeric keys and then press OK The display flashes the hours 3 Scroll to set the hours and then press OK to accept the setting The display flashes the minutes 4 Scroll to set the minutes and then press OK to accept the setting The display flashes AM P...

Page 41: ... to accept the setting The display flashes the day 6 Scroll to set the day and then press OK to accept the setting The display shows the programmed date 7 Press Status twice to exit Revision To display the firmware revision of the system scroll until the display shows Revision This is a read only menu Press Status to exit Contrast To adjust the contrast of the display 1 Scroll until the display sh...

Page 42: ...54321 54321 4321 factory default or 321 This code is limited to changing all but the following Dealer code code length downloader code phone lock phone 1 phone 2 phone 1 report mode phone 2 report mode HW1 function Access codes Function Default Description Dealer code 4321 You can use the dealer code to program all system options including high security options that are not accessible with the ins...

Page 43: ...alues when a memory clear is performed off The following are not reset when on account number dealer code code length call wait cancel phone numbers 1 and 2 phone report modes 1 to 4 phone lock downloader phone number downloader code Auto arm On Determines how long the system protests announces open failed sensors when attempting to arm with open failed sensors before bypassing these sensors and a...

Page 44: ...utside briefly and return If the system is armed and you press Disarm the panel announces Exit Time is On and sounds exit delay beeps This allows a designated entry exit door to open for up to two minutes without causing alarm When the door is closed the beeps stop and the door is armed again Downloader enable On Enables programming of system options with downloader software Sup protest Off Determ...

Page 45: ...nswers a remote phone access or Enterprise call Depending on whether an answering machine exists at the panel location offsite access to the panel can be done with a series of phone calls or just one For offsite access where an answering machine does not exist the user or Enterprise operator simply calls the panel location once and listens for 10 rings The panel should answer after the tenth ring ...

Page 46: ...t the panel from calling the central station The call waiting code is programmed the same way as a dialer number Sensors Table 14 below describes the Sensors menu Table 14 Sensors menu Function Description Learn sensors Adds learns sensors to panel memory Delete sensors Deletes sensors from panel memory Edit sensors Edits sensor information in panel memory The following instructions tell how to ad...

Page 47: ...group number displayed The sensor text flashes 7 Scroll through the text list and then press OK to accept the first text segment 8 You may enter more text or press OK again to finish adding the sensor The display shows Trip Sensor with the next available sensor number 9 Press Status repeatedly to exit To delete a sensor 1 Scroll until the display shows System Programming and then press OK The disp...

Page 48: ...the light blinks Remote handheld touchpad Press the emergency buttons Key fob Press the Lock and Unlock buttons at the same time ELM key fob Do the following 1 Press the Unlock button twice and hold it the third time The light button flashes three times 2 Press the Unlock button once and hold it the second time The light button flashes twice 3 Press and hold the Unlock button The light button flas...

Page 49: ...port to a central station if the user bypasses protesting sensors indirect bypass when arming the system on or not off AC power failure Off Determines whether the panel sends AC power failure reports to a central station after the programmed time expires The time can be set from 005 to 254 minutes When the panel is without AC power for 30 seconds the panel LEDs turn off When the panel is without A...

Page 50: ... off The panel sends a report whenever the dealer Utility 1 or installer Utility 2 code is used to enter programming mode and another report is sent when the programming session ends Fire verify Off If this option is off the panel immediately reports to the central station when a smoke detector goes into alarm With this option on if a single smoke detector goes into alarm the panel will not report...

Page 51: ... the system Beeps sound after arming the system to remind you to leave the armed premises If a delay door is opened after the exit delay expires the entry delay begins If you arm the system with no delay and open a delay door after the exit delay expires an alarm occurs No activity tm Off Determines whether the panel sends a no activity report to a central station when the programmed time elapses ...

Page 52: ...re to work Fail to close time Off Determines whether the panel sends a fail to close report to a central station if the system has not been armed by the programmed time on or not off System time must be set correctly for this feature to work Siren time out 005 minutes Determines how long sirens sound alarms if no one is present to disarm the system The time can be set from 002 to 254 minutes When ...

Page 53: ... entry delays on or arm and disarm the system anytime off If this option and the key fob no delay option are on you cannot enter and or disarm using remote touchpads without causing an alarm System options Table 20 below describes the System Options menu Table 20 System Options menu Function Default Description RF jam detect Off Determines whether the panel checks for and reports RF interference j...

Page 54: ...s silent off Panel voice On Determines whether the panel announces arming level changes on or not off Panel piezo alarm On Determines whether the panel piezo emits alarm sounds on or not off Trouble beeps On Determines whether the panel and hardwired interior sirens sound six beeps every minute when a trouble condition occurs on or not off The following conditions cause trouble beeps AC power fail...

Page 55: ...nt on alarm Panel tamper alarm Off Determines whether the panel activates a tamper alarm anytime the cover is opened On or only when the system is armed Off Alarm report verify Off Determines whether the panel verifies successful alarm reports to the central station by displaying Phone comm OK on or not off Piezo beep options Table 22 below describes piezo beep options Table 22 Piezo beep options ...

Page 56: ...n instant audio session 2 Callback Panel hangs up and waits for a callback from the central station operator before starting an audio session Off No audio verification Fire shutdown Off Determines whether system fire sirens are silenced during a two way audio session on or not off Beeps sound every 10 seconds while sirens are silenced Panic talk Off Determines whether the central station operator ...

Page 57: ...e is 01 lowest to 64 highest Light control optional If your system uses optional X10 modules you can program them to control lights Note This feature has not been investigated for use by UL X10 module operation Use the following procedure to program X10 module operations into panel memory To program the housecode 1 Press the scroll buttons until the panel displays System programming 2 Press Enter ...

Page 58: ...roll buttons until the panel displays Light control 5 Press Enter The panel displays Set entry lights 6 Press the scroll buttons until the panel displays Sensor light 7 Press Enter The panel displays Sn Text X 10 unit on off 8 Press the scroll buttons until the panel displays the sensor number you want to activate 9 Press Enter The panel displays On off which will be flashing 10 Press the scroll b...

Page 59: ... the sensor activated lights feature from turning on sensor activated lights Note System time must be set correctly for this feature to work When a time value is set on and the sensor activated lights feature is on the panel prevents sensor activated lights from turning on between the programmed start time this option and the programmed stop time Both sensor activated light lockout start time and ...

Page 60: ...oad This feature initiates a phone call from the panel to the Enterprise Downloader Resetting memory to factory defaults To reset the panel to factory defaults 1 Open the panel cover 2 Unplug the transformer and disconnect the battery 3 Press and hold the four arming status buttons Doors Windows Motions Disarm and Status on the front of the panel and the tamper switch on the inside of the panel 4 ...

Page 61: ...el clock 2 Add learn sensors 3 Change options as needed Note If phone lock is on phone numbers 1 and 2 downloader phone number account number phone lock downloader code phone report modes 1 to 4 access code length and call waiting and dealer code will not reset to their defaults ...

Page 62: ...ress Motions a second time to turn the latchkey option on The button blinks when latchkey is on Disarm The panel will prompt you to enter an access code Enter the appropriate code The panel will disarm doors windows and motion sensors Status Press Status for panel to display and speak the system status Police Press and hold or press the button twice quickly to activate a nonmedical police fire or ...

Page 63: ...r related problem occurs Note While the sensor test is a valuable installation and service tool it only tests sensor operation for the current conditions You should perform a sensor test after any change in environment equipment or programming Notify the central station you will be performing a test prior to starting the test To test the sensors 1 Place all sensors in their secured no alarm state ...

Page 64: ...e of rise heat detector Rub your hand together until warm and then place one hand on the detector for 30 seconds Shock Tap the glass twice away from the sensor Wait at least 10 seconds before testing again Smoke Press and hold the test button until the system sounds transmission beeps Personal help button Press and hold the appropriate help button until the light blinks and the panel sounds for at...

Page 65: ...ensor To relocate a sensor 1 Test the sensor a few inches from the original position 2 Increase the distance from the original position and retest until an acceptable location is found 3 Mount the sensor in the new location 4 If no location is acceptable replace the sensor To replace a sensor 1 Test a known good sensor at the same location 2 If the transmission beeps remain below the minimum level...

Page 66: ...e 30 Phone commands System function Phone command Disarm 1 Arm doors windows 2 Arm motion sensors 3 Arm doors windows with no entry delay 2 2 Arm motion sensors with latchkey 3 3 Arm doors windows and motion sensors 2 3 Arm doors windows with no entry delay and motion sensors with latchkey 2 2 3 3 Specific light on unit number Specific light off unit number All lights on All lights off System stat...

Page 67: ...touchpad 0 Key fob 1 to 40 sensor number Panel auxiliary panic 41 Panel tamper 42 Panel police panic 43 Panel fire panic 44 Dealer access code 44 Installer access code 45 Master code 46 Access codes 1 to 8 47 to 54 Duress code 55 Two way voice operation For the central station operator to initiate an audio session 1 After the panel has completed reporting the alarm pick up the CS phone and press t...

Page 68: ...n pick up the phone after it starts ringing You should hear the panel voice announce Press Star for Alarm 4 Press and the panel voice identifies the alarm If there is more than one alarm in progress you must press for the panel voice to identify them After all alarms have been identified the panel announces Press to Exit 5 Press to terminate the call You must terminate the call by pressing Otherwi...

Page 69: ... the siren timeout expires Siren priority is fire highest priority intrusion and emergency Table 33 below identifies the light information for each of these siren types Table 33 Alarm siren and X10 light information Fire Intrusion Emergency X10 lights Steady Flashing Steady X10 siren Steady Steady Alarm beeps Interior and panel siren Temporal 3 Steady Fast on off If an alarm of greater priority oc...

Page 70: ...panel backup battery voltage If less than 5 4 volts replace the battery and clear the system status message Run a sensor test If the panel displays and announces RF Jam the control panel has detected RF interference If the panel displays and announces that a sensor is open see Sensors on page 40 If the display shows Set Time and announces System Time is Not Set set the system time Control panel If...

Page 71: ...utes after installing a new battery to test the sensor Adjust the sensor mounting Leave the area for 3 minutes then retest The environment may be too hot or too cold Outdoor sensors operate between 32 and 120ºF 0 and 49ºC Dirt or dust may be causing the problem Wipe the sensor with a clean damp cloth Specifications Power 9 VAC 60 Hz 25 VA transformer minimum Rechargeable battery 6 0 VDC 1 2 Ah lea...

Page 72: ...Living room 018 Living room window 008 Master bedroom 009 Master bedroom window 037 Medicine cabinet 041 Module 024 Office 025 Office window 131 Patio 023 Patio door 042 Phone module 134 Pool 021 Porch 022 Porch window 139 Room 132 Sliding door 029 Special chime 143 Sun room 040 System panic 001 Touchpad 138 Toy room 032 Upstairs 033 Upstairs window 016 Utility room 135 Window Table 35 Sensor name...

Page 73: ...dule 043 A 044 B 045 C 046 D 047 E 048 F 049 G 050 H 051 I 052 J 053 K 054 L 055 M 056 N 057 O 058 P 059 Q 060 R 061 S 062 T 063 U 064 V 065 W 066 X 067 Y 068 Z 069 0 070 1 071 2 072 3 073 4 074 5 075 6 077 8 078 9 079 080 081 082 083 084 085 086 087 088 089 090 091 092 _ 093 094 095 096 097 098 099 100 101 102 space 103 a 104 b 105 c 106 d 107 e 108 f 109 g 110 h 111 i 112 j 113 k 114 l 115 m 116...

Page 74: ...68 Simon XT Installation Manual ...