NX-148E- RF LCD Touchpad w ith Receiver Installation Instructions 

Assign user authority  (6) 

To assign user authority levels, you must have authority over 

the assigned partitions. To assign user authority, do the 

following: 

1.  Enter * 6. 

2.  Enter your master code.  

3.  Enter the user number. 

4.  Use keys 1 (yes) and 0 (no) to assign authorities when 

prompted, or press * to move to the next prompt. 

5.  Assign the partitions for the user. 

6.  To return to step 3 and program another user code, press 

*. 

7.  To exit,  press #. 

Note

: Retain at least one code with access rights to all 

partitions to allow adding future users. 

Reset function  (7) 

The system must be disarmed to reset the s moke detectors, 

zone troubles, and zone tampers. To reset, do the following: 

1.  Enter * 7.  

2.  To exit,  press #. 

Note

: If the keypad begins beeping, the reset didn’t 

execute properly. Enter your code to silence the touchpa d. 

Wait a few minutes and repeat the reset. 

Log review (90) 

The control panel has an event log of at least the last 185 

events along with the date, time, and partition where the event 

occurred. To review the log, do the following: 

1.  Enter * 90.  

2.  Enter your program or master code. 

3.  Press   to view events from newest to oldest, or press 

to view events from oldest to newest. 

4.  To exit,  press #. 

The following screen sample shows an opening in Partition 3 

on September 25th at 5:57 pm by user 75. The * indicates that 

this event is not programmed to be reported to the central 

monitoring station. 

Open                  75 
9/25     17:57        P3* 

Table 10 

lists some of the possible event log messages. 

Adjust view/brightness of LCD (91)

 

To adjust the view and brightness of the LCD display, do the 

following: 

1.  Enter * 91. 

2.  Enter your master code.  

3.  Press   or   to raise or lower the view angle and press * to 

save the selection. 

4.  Press   or   to brighten or dim the LCD and press * to 

save the selection. 

5.  To exit,  press #. 

Program custom messages (92) 

When you program custom messages: 

• 

If an NX-148 (non-E) is installed on the same system, it 

must be used to program the text.  All messages are 

transferred to other touchpads when you exit this mode.  

• 

Use the * 94 (

Set touchpad  number and partition

function to set the touchpad numbers prior to 

programming custom messages. 

• 

If a touchpad is added after messages are programmed, 

you need to either program all messages in it, or enter 

custom message programming on an existing touchpad 

and press 1 #, #, #, EXIT.   

• 

Refer to * 93 (

Set touchpad options

)  to prevent 

overwriting the custom message. 

To program custom messages, do the following: 

1.  Enter * 92.  

2.  Enter your program code.  

3.  The LCD will prompt you to enter the message number 

followed by #. Zones 1 through 192 custom messages are 

message numbers 1 to 192 respectively.  

Message 193 = Custom message top line. 

Message 194 = Custom message bottom line. 

Message 195 = Shutdown message top line. 

Message 196 = Shutdown message bottom line. 

Enter the message number and press #. The display will 

show the zone number on the top line and a description on 

the bottom line. Refer to 

Table 7

 for information on editing 

character data. 

4.  Press EXIT to exit 

Summary of Contents for NX-148E-RF

Page 1: ...8E NX 8V2 NX 6V2 or NX 4V2 and downloading via modem make sure the control panel version is equal to or greater than the following versions NX 8E 17 00 NX 8V2 1 04 NX 6V2 1 05 NX 4V2 1 04 Make sure yo...

Page 2: ...18 2000 ft 610 m 16 2500 ft 760 m 16 7 Run the antenna wires through the antenna holes in the mounting plate Figure 2 and into the wall 8 To mountthe touchpad to the mounting plate place the top of t...

Page 3: ...bank Location 594 The bank setting is based on the zone capabilities ofboth the receiver and the panel and mustbe set before you add learn transmitters 6 Enter 400 to enter the sensor transm itter le...

Page 4: ...er will be displayed for the keyfob partitions Press the partition number to toggle the partition on and off 6 To continue programming keyfob transmitter partition settings repeatsteps 4 to 8 7 To exi...

Page 5: ...Note Press repeatedlyto scroll through available functions Table 4 Touchpad functions Function number Function 0 Adjust touchpad tone 1 Temp master mode View zone status 2 Service menu 3 View alarmmem...

Page 6: ...ss or to turn the selected device on or off 4 Repeatsteps 2 and 3 until all devices have been programmed 5 To exit press Unit and house codes for X10 47 To program the specific X10 unit and house code...

Page 7: ...the central monitoring station Open 75 9 25 17 57 P3 Table 10 lists some ofthe possible eventlog messages Adjust view brightness ofLCD 91 To adjustthe view and brightness ofthe LCD display do the fol...

Page 8: ...ge Enables custommessage display 10 Clock Enables clockdisplay 11 Custom message lock Prevents over writing the custom message during touchpad copy 12 Select an option Programs specialcharacteristics...

Page 9: ...the tampered zone Zone low battery press A w ireless devicehas a low battery Press to identify the zone Zone lost press A w ireless or multiplexed zone device is not reporting to the control Press to...

Page 10: ...ob Partition 8 keyfob Zone _____ Assigned to module _____ RM HE P 1 Enable sensor 2 Supervised 3 Fire supervision 4 Input option 1 5 Input option 2 _ 6 8 Not used Partition 1 keyfob Partition 2 keyfob...

Page 11: ...Partition 2 keyfob Partition 3 keyfob Partition 4 keyfob Partition 5 keyfob Partition 6 keyfob Partition 7 keyfob Partition 8 keyfob Zone _____ Assigned to module _____ RM HE P 1 Enable sensor 2 Supe...

Page 12: ...Partition 2 keyfob Partition 3 keyfob Partition 4 keyfob Partition 5 keyfob Partition 6 keyfob Partition 7 keyfob Partition 8 keyfob Zone _____ Assigned to module _____ RM HE P 1 Enable sensor 2 Supe...

Page 13: ...sor 2 Supervised 3 Fire supervision 4 Input option 1 5 Input option 2 _ 6 8 Not used Partition 1 keyfob Partition 2 keyfob Partition 3 keyfob Partition 4 keyfob Partition 5 keyfob Partition 6 keyfob P...

Page 14: ...temperature 30 to 140 F 34 to 60 C Humidity 90 relative noncondensing Dimensions 5 x 6 x 1 in 12 7 x 15 2 x 2 5 cm Regulatory information FCC compliance This device complies w ith part 15 of the FCC...

Reviews: