Figure 10: Main web interface screen 

 

4.  The switch menu on the left side of the web page permits 

access to the commands and statistics provided by the 
industrial managed switch.  

 

Refer to the User Manual for further information about using 
the web management interface. 

Note

: For security purposes, change and memorize the new 

password after this first setup. 

Saving the configuration 

The running configuration file is stored in the RAM of the 
managed switch. In the current version, the running 
configuration sequence of running-config can be saved from 
the RAM to FLASH by executing the Save Startup Config 
command. After doing this, the running configuration sequence 
becomes the startup configuration file (i.e., the saved 
configuration). 

To save all applied changes and set the current configuration 
as a startup configuration, the startup-configuration file is 
loaded automatically across a system reboot. 

1.  Click 

System

 > 

Save Startup Config

.  

 

2.  Click the 

Save Configuration

 button. 

 

Resetting the switch to default 

To reset the IP address to the default IP address

 

“192.168.0.100” and the user password to factory default mode 
(default password is “admin”), press the hardware reset button 
on the front panel for about 10 seconds. After the device is 
rebooted, log in to the management web interface within the 
same subnet of 192.168.0.xx and default password. Note that 
all the previous setups are erased after the factory default 
reset. 

Figure 11: Reset button 

 

 

Summary of Contents for NS3552-8P-2S-V2

Page 1: ...anagement purposes The following equipment is necessary for further management Workstations running Windows XP 2003 Vista 7 8 2008 10 MAC OS X or later Linux UNIX or other platforms are compatible with TCP IP protocols Workstations are installed with Ethernet NIC Network Interface Card Serial port connection Terminal The above workstations come with a COM Port DB9 or USB to RS 232 converter The ab...

Page 2: ...not mount the switch horizontally as this does not allow air to flow up into the device and will result in damage to the switch Do not tie DC1 to DC2 DC2 is for secondary power redundancy Do not plug DC power into the device while the AC power cord is plugged in This is not a hot swappable switch Hot swapping this device will result in damage DIN rail mounting installation To replace the wall moun...

Page 3: ...ivity A terminal program is required to make the software connected to the industrial managed switch Windows Hyper Terminal program may be a good choice The Hyper Terminal can be accessed from the Start menu 1 Click Start Programs Accessories Hyper Terminal 2 When the following screen appears ensure that the COM port is configured as shown below Click OK when finished with configuration 3 Log in t...

Page 4: ...ch through the new IP address Note If unfamiliar with the console command or the related parameter type help in the console to obtain the Help description Starting web management The section describes how to start up the web management function for the industrial managed switch Note that the industrial managed switch is configured through an Ethernet connection Ensure that the manager computer is ...

Page 5: ...g command After doing this the running configuration sequence becomes the startup configuration file i e the saved configuration To save all applied changes and set the current configuration as a startup configuration the startup configuration file is loaded automatically across a system reboot 1 Click System Save Startup Config 2 Click the Save Configuration button Resetting the switch to default...

Page 6: ...286 8889 E techsupport interlogix com W www interlogix com support Latin America T 1 561 998 6114 E latam interlogix com Europe Middle East and Africa W Select Contact Us at www firesecurityproducts com Australia E security tech support interlogix com au W www utcfs com au support ...

Reviews: